{"id":1200,"date":"2026-10-15T15:36:04","date_gmt":"2026-10-15T10:06:04","guid":{"rendered":"https:\/\/neometrixgroup.com\/resources\/?p=1200"},"modified":"2026-10-15T15:36:04","modified_gmt":"2026-10-15T10:06:04","slug":"field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt","status":"publish","type":"post","link":"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/","title":{"rendered":"Field Technical Shelter: The Field Stops Equipment. A Shelter Doesn&#8217;t."},"content":{"rendered":"<h1>Field Technical Shelter: The Field Stops Equipment. A Shelter Doesn&#8217;t.<\/h1>\n<p>Electronics, communications, a command team, a workshop &#8212; none of them work for long in the open at 50 C, in dust, at altitude, under electromagnetic interference or under a CBRN threat. A field technical shelter is the hardened box that carries a controlled, protected environment to wherever the task is, and holds it there. Neometrix engineers it as a transportable, environmentally hardened enclosure, fitted out turnkey.<\/p>\n<h2>Build It, Deploy It, Operate It<\/h2>\n<p><strong>The shell.<\/strong> A welded steel or aluminium frame clad in insulated sandwich panels, with ISO corner castings, full sealing and weatherproofing, and a blast or ballistic option.<\/p>\n<p><strong>Environmental systems.<\/strong> HVAC held to +\/-50 C ambient with humidity control, power distribution and conditioning, lighting and blackout.<\/p>\n<p><strong>Hardening.<\/strong> EMI\/RFI shielding for signal integrity and emission control, NBC over-pressure and filtration, a ballistic protection option, and shock- and vibration-isolated racks, each added only where the task needs it.<\/p>\n<p><strong>Fit-out and integration.<\/strong> Workstations, racks and consoles, cabling and trunking, and mast, antenna and cable-entry provisions, installed turnkey around the payload.<\/p>\n<h2>Transportable by Road, Rail or Air<\/h2>\n<p>On an ISO frame (ISO 1C class, 8-20 ft footprint) with corner castings and levelling jacks, the shelter is transported, set down, levelled, powered and operating on any ground, so capability arrives where it is needed and ready to work.<\/p>\n<h2>One Shell, Many Roles<\/h2>\n<p>The same shell becomes a command post, a technical or comms shelter, a medical module, a workshop or a store.<\/p>\n<h2>Honest About Sourcing<\/h2>\n<p>The shell, environmental systems, hardening and fit-out and integration are in-house fabrication and integration work. Mission electronics, radios and computing are bought in or government-furnished. The class is engineered to order, and no specific delivered shelter is claimed.<\/p>\n<h2>Frequently Asked Questions<\/h2>\n<p><strong>Why harden a shelter beyond just air conditioning?<\/strong><br \/>\nBecause weather is only one of the field&#8217;s threats. Electronics can be disrupted by electromagnetic interference or leak emissions, crews can face CBRN risk, and shelters may need ballistic or blast protection. Hardening options such as EMI\/RFI shielding, NBC over-pressure and filtration, and ballistic layers are added to the threat the payload and crew actually face, rather than as a blanket specification.<\/p>\n<p><strong>Can one shelter design serve different roles?<\/strong><br \/>\nYes. Because the structural shell, environmental systems and hardening are separate from the fit-out, the same basic enclosure can be integrated as a command post, comms shelter, medical module, workshop or store, with racks, consoles, cabling and antenna provisions tailored to the payload.<\/p>\n<h2>Get In Touch<\/h2>\n<p>For specifications, RFQs, or a discussion about field shelters:<br \/>\n&#8211; <strong>Product page:<\/strong> <a href=\"https:\/\/neometrixgroup.com\/products\/field-technical-shelter\" target=\"_blank\" rel=\"noopener\">Field Technical Shelter<\/a><br \/>\n&#8211; <strong>Email:<\/strong> contact@neometrixgroup.com<br \/>\n&#8211; <strong>Phone:<\/strong> +91-7777-876-876<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Field Technical Shelter: The Field Stops Equipment. A Shelter Doesn&#8217;t. Electronics, communications, a command team, a workshop &#8212; none of them work for long in the open at 50 C, in dust, at altitude, under electromagnetic interference or under a CBRN threat. A field technical shelter is the hardened box that carries a controlled, protected [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":1201,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[24],"tags":[611,612,608,610,613,609],"class_list":["post-1200","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-defence-military","tag-command-post-shelter","tag-emi-shielded-shelter","tag-field-technical-shelter","tag-iso-frame-shelter","tag-nbc-over-pressure","tag-transportable-shelter"],"blocksy_meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Field Technical Shelter: The Field Stops Equipment. A Shelter Doesn&#039;t. - Resources<\/title>\n<meta name=\"description\" content=\"Neometrix field technical shelter -- a transportable, ISO-frame hardened shelter with HVAC held to +\/-50 C, optional EMI\/RFI shielding, NBC over-pressure and ballistic protection, fitted out turnkey as a command post, comms shelter, workshop or store.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Field Technical Shelter: The Field Stops Equipment. A Shelter Doesn&#039;t. - Resources\" \/>\n<meta property=\"og:description\" content=\"Neometrix field technical shelter -- a transportable, ISO-frame hardened shelter with HVAC held to +\/-50 C, optional EMI\/RFI shielding, NBC over-pressure and ballistic protection, fitted out turnkey as a command post, comms shelter, workshop or store.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/\" \/>\n<meta property=\"og:site_name\" content=\"Resources\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/neometrixgroup\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-15T10:06:04+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/neometrixgroup.com\/resources\/wp-content\/uploads\/2026\/10\/wp_featured_1792058757.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"896\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Rajeev Sharma\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@neometrixgroup\" \/>\n<meta name=\"twitter:site\" content=\"@neometrixgroup\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Rajeev Sharma\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/\"},\"author\":{\"name\":\"Rajeev Sharma\",\"@id\":\"https:\/\/neometrixgroup.com\/resources\/#\/schema\/person\/21060ef53e1490769a4abbb9bba3b131\"},\"headline\":\"Field Technical Shelter: The Field Stops Equipment. A Shelter Doesn&#8217;t.\",\"datePublished\":\"2026-10-15T10:06:04+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/\"},\"wordCount\":452,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/neometrixgroup.com\/resources\/#organization\"},\"image\":{\"@id\":\"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/neometrixgroup.com\/resources\/wp-content\/uploads\/2026\/10\/wp_featured_1792058757.jpg\",\"keywords\":[\"command post shelter\",\"EMI shielded shelter\",\"field technical shelter\",\"ISO frame shelter\",\"NBC over-pressure\",\"transportable shelter\"],\"articleSection\":[\"Defence &amp; Military\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/\",\"url\":\"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/\",\"name\":\"Field Technical Shelter: The Field Stops Equipment. A Shelter Doesn't. - Resources\",\"isPartOf\":{\"@id\":\"https:\/\/neometrixgroup.com\/resources\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/neometrixgroup.com\/resources\/wp-content\/uploads\/2026\/10\/wp_featured_1792058757.jpg\",\"datePublished\":\"2026-10-15T10:06:04+00:00\",\"description\":\"Neometrix field technical shelter -- a transportable, ISO-frame hardened shelter with HVAC held to +\/-50 C, optional EMI\/RFI shielding, NBC over-pressure and ballistic protection, fitted out turnkey as a command post, comms shelter, workshop or store.\",\"breadcrumb\":{\"@id\":\"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/#primaryimage\",\"url\":\"https:\/\/neometrixgroup.com\/resources\/wp-content\/uploads\/2026\/10\/wp_featured_1792058757.jpg\",\"contentUrl\":\"https:\/\/neometrixgroup.com\/resources\/wp-content\/uploads\/2026\/10\/wp_featured_1792058757.jpg\",\"width\":1200,\"height\":896,\"caption\":\"Deployed hardened field shelter on an ISO frame with HVAC, cable entries and levelling jacks\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/neometrixgroup.com\/resources\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Field Technical Shelter: The Field Stops Equipment. A Shelter Doesn&#8217;t.\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/neometrixgroup.com\/resources\/#website\",\"url\":\"https:\/\/neometrixgroup.com\/resources\/\",\"name\":\"Neometrix Resources\",\"description\":\"Neometrix\",\"publisher\":{\"@id\":\"https:\/\/neometrixgroup.com\/resources\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/neometrixgroup.com\/resources\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/neometrixgroup.com\/resources\/#organization\",\"name\":\"Neometrix Defence Limited\",\"url\":\"https:\/\/neometrixgroup.com\/resources\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/neometrixgroup.com\/resources\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/neometrixgroup.com\/resources\/wp-content\/uploads\/2025\/02\/cropped-cropped-cropped-logo.png\",\"contentUrl\":\"https:\/\/neometrixgroup.com\/resources\/wp-content\/uploads\/2025\/02\/cropped-cropped-cropped-logo.png\",\"width\":446,\"height\":70,\"caption\":\"Neometrix Defence Limited\"},\"image\":{\"@id\":\"https:\/\/neometrixgroup.com\/resources\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/neometrixgroup\",\"https:\/\/x.com\/neometrixgroup\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/neometrixgroup.com\/resources\/#\/schema\/person\/21060ef53e1490769a4abbb9bba3b131\",\"name\":\"Rajeev Sharma\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/neometrixgroup.com\/resources\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/a57ab55bb6a77384e9bc5c0fc789a3e524af3dc1e854abc3c15932aeb94b4a85?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/a57ab55bb6a77384e9bc5c0fc789a3e524af3dc1e854abc3c15932aeb94b4a85?s=96&d=mm&r=g\",\"caption\":\"Rajeev Sharma\"},\"sameAs\":[\"http:\/\/neometrixgroup.com\"],\"url\":\"https:\/\/neometrixgroup.com\/resources\/author\/admin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Field Technical Shelter: The Field Stops Equipment. A Shelter Doesn't. - Resources","description":"Neometrix field technical shelter -- a transportable, ISO-frame hardened shelter with HVAC held to +\/-50 C, optional EMI\/RFI shielding, NBC over-pressure and ballistic protection, fitted out turnkey as a command post, comms shelter, workshop or store.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/","og_locale":"en_US","og_type":"article","og_title":"Field Technical Shelter: The Field Stops Equipment. A Shelter Doesn't. - Resources","og_description":"Neometrix field technical shelter -- a transportable, ISO-frame hardened shelter with HVAC held to +\/-50 C, optional EMI\/RFI shielding, NBC over-pressure and ballistic protection, fitted out turnkey as a command post, comms shelter, workshop or store.","og_url":"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/","og_site_name":"Resources","article_publisher":"https:\/\/www.facebook.com\/neometrixgroup","article_published_time":"2026-10-15T10:06:04+00:00","og_image":[{"width":1200,"height":896,"url":"http:\/\/neometrixgroup.com\/resources\/wp-content\/uploads\/2026\/10\/wp_featured_1792058757.jpg","type":"image\/jpeg"}],"author":"Rajeev Sharma","twitter_card":"summary_large_image","twitter_creator":"@neometrixgroup","twitter_site":"@neometrixgroup","twitter_misc":{"Written by":"Rajeev Sharma","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/#article","isPartOf":{"@id":"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/"},"author":{"name":"Rajeev Sharma","@id":"https:\/\/neometrixgroup.com\/resources\/#\/schema\/person\/21060ef53e1490769a4abbb9bba3b131"},"headline":"Field Technical Shelter: The Field Stops Equipment. A Shelter Doesn&#8217;t.","datePublished":"2026-10-15T10:06:04+00:00","mainEntityOfPage":{"@id":"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/"},"wordCount":452,"commentCount":0,"publisher":{"@id":"https:\/\/neometrixgroup.com\/resources\/#organization"},"image":{"@id":"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/#primaryimage"},"thumbnailUrl":"https:\/\/neometrixgroup.com\/resources\/wp-content\/uploads\/2026\/10\/wp_featured_1792058757.jpg","keywords":["command post shelter","EMI shielded shelter","field technical shelter","ISO frame shelter","NBC over-pressure","transportable shelter"],"articleSection":["Defence &amp; Military"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/","url":"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/","name":"Field Technical Shelter: The Field Stops Equipment. A Shelter Doesn't. - Resources","isPartOf":{"@id":"https:\/\/neometrixgroup.com\/resources\/#website"},"primaryImageOfPage":{"@id":"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/#primaryimage"},"image":{"@id":"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/#primaryimage"},"thumbnailUrl":"https:\/\/neometrixgroup.com\/resources\/wp-content\/uploads\/2026\/10\/wp_featured_1792058757.jpg","datePublished":"2026-10-15T10:06:04+00:00","description":"Neometrix field technical shelter -- a transportable, ISO-frame hardened shelter with HVAC held to +\/-50 C, optional EMI\/RFI shielding, NBC over-pressure and ballistic protection, fitted out turnkey as a command post, comms shelter, workshop or store.","breadcrumb":{"@id":"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/#primaryimage","url":"https:\/\/neometrixgroup.com\/resources\/wp-content\/uploads\/2026\/10\/wp_featured_1792058757.jpg","contentUrl":"https:\/\/neometrixgroup.com\/resources\/wp-content\/uploads\/2026\/10\/wp_featured_1792058757.jpg","width":1200,"height":896,"caption":"Deployed hardened field shelter on an ISO frame with HVAC, cable entries and levelling jacks"},{"@type":"BreadcrumbList","@id":"https:\/\/neometrixgroup.com\/resources\/field-technical-shelter-the-field-stops-equipment-a-shelter-doesnt\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/neometrixgroup.com\/resources\/"},{"@type":"ListItem","position":2,"name":"Field Technical Shelter: The Field Stops Equipment. A Shelter Doesn&#8217;t."}]},{"@type":"WebSite","@id":"https:\/\/neometrixgroup.com\/resources\/#website","url":"https:\/\/neometrixgroup.com\/resources\/","name":"Neometrix Resources","description":"Neometrix","publisher":{"@id":"https:\/\/neometrixgroup.com\/resources\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/neometrixgroup.com\/resources\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/neometrixgroup.com\/resources\/#organization","name":"Neometrix Defence Limited","url":"https:\/\/neometrixgroup.com\/resources\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/neometrixgroup.com\/resources\/#\/schema\/logo\/image\/","url":"https:\/\/neometrixgroup.com\/resources\/wp-content\/uploads\/2025\/02\/cropped-cropped-cropped-logo.png","contentUrl":"https:\/\/neometrixgroup.com\/resources\/wp-content\/uploads\/2025\/02\/cropped-cropped-cropped-logo.png","width":446,"height":70,"caption":"Neometrix Defence Limited"},"image":{"@id":"https:\/\/neometrixgroup.com\/resources\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/neometrixgroup","https:\/\/x.com\/neometrixgroup"]},{"@type":"Person","@id":"https:\/\/neometrixgroup.com\/resources\/#\/schema\/person\/21060ef53e1490769a4abbb9bba3b131","name":"Rajeev Sharma","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/neometrixgroup.com\/resources\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/a57ab55bb6a77384e9bc5c0fc789a3e524af3dc1e854abc3c15932aeb94b4a85?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/a57ab55bb6a77384e9bc5c0fc789a3e524af3dc1e854abc3c15932aeb94b4a85?s=96&d=mm&r=g","caption":"Rajeev Sharma"},"sameAs":["http:\/\/neometrixgroup.com"],"url":"https:\/\/neometrixgroup.com\/resources\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/neometrixgroup.com\/resources\/wp-json\/wp\/v2\/posts\/1200","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/neometrixgroup.com\/resources\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/neometrixgroup.com\/resources\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/neometrixgroup.com\/resources\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/neometrixgroup.com\/resources\/wp-json\/wp\/v2\/comments?post=1200"}],"version-history":[{"count":1,"href":"https:\/\/neometrixgroup.com\/resources\/wp-json\/wp\/v2\/posts\/1200\/revisions"}],"predecessor-version":[{"id":1202,"href":"https:\/\/neometrixgroup.com\/resources\/wp-json\/wp\/v2\/posts\/1200\/revisions\/1202"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/neometrixgroup.com\/resources\/wp-json\/wp\/v2\/media\/1201"}],"wp:attachment":[{"href":"https:\/\/neometrixgroup.com\/resources\/wp-json\/wp\/v2\/media?parent=1200"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/neometrixgroup.com\/resources\/wp-json\/wp\/v2\/categories?post=1200"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/neometrixgroup.com\/resources\/wp-json\/wp\/v2\/tags?post=1200"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}