200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Priority Panels / 230 Bar · Priority Valve / SS 316 · Ham-Let Israel / CNG Vehicle Filling Neometrix · India
    Priority Panels · Neometrix

    CNG priority
    panels.

    Designed and fabricated in-house — customized Priority Panels for testing and filling of CNG vehicles. Built around an extremely reliable and robust Priority Valve with all components in SS 316 from Ham-Let, Israel.

    Priority Panels — Neometrix
    Fig · 01 Priority Panel — CNG vehicle filling system
    Operating Pressure
    230Bar
    Flow Rate
    3,000m³/hr+
    Material
    SS 316Ham-Let, Israel
    Application
    CNGVehicle Filling
    01
    Overview

    Priority panels. Ready to use.

    Customized Priority Panels for testing and filling of CNG vehicles, built around a proven Priority Valve and manufactured entirely from SS 316 components for maximum corrosion resistance and long service life.

    Neometrix Priority Panels, our flagship priority panel CNG station equipment, are designed and fabricated in-house to customer specifications for testing and filling of CNG vehicles. Each CNG panel is designed around our own extremely reliable and robust Priority Valve. All components used in the panels are manufactured from high quality stainless steel SS 316 sourced from Ham-Let, Israel, ensuring maximum corrosion resistance and a long service life.

    Before dispatch, all Priority Panels are tested on natural gas at the in-house CNG Station. This ensures that on arrival your priority panel is ready to use and no additional on-site adjustments are required.

    Tested on natural gas before dispatch. Ready to use on arrival.

    Priority Valves open only when inlet pressure reaches 230 BAR. Gas is then allowed to flow to the common outlets on the bottom and right hand side of the valves. When all banks reach 230 BAR, they fill up together until the compressor shuts off.

    02
    Key Features

    Built for CNG filling.

    Feature · 01

    Ultra High Flow Rates

    Panels are designed for compressor flow rates in excess of 3,000 m³/hr for fast and efficient CNG vehicle filling operations.

    3,000+ m³/hr · High Throughput
    Feature · 02

    No Reverse Flow

    Check valves on each line prevent reverse flow through the priority panel, protecting the storage banks and compressor at all times.

    Check Valves · Reverse Flow Protection
    Feature · 03

    Large Flow Range — KG80 Meter

    The KG80 meter is accurate over the range 1–80 kg/min and has been approved to the latest OIML standard: “Compressed Gaseous Fuel Measuring Systems for Vehicles”.

    1–80 kg/min · OIML Approved
    Feature · 04

    Easy Maintenance

    The station can be kept running while the manual isolation valves are shut for maintenance work. Pipe work does not need to be removed for servicing the panels.

    In-Service Maintenance · Minimal Downtime
    Feature · 05

    Simple Operation — 230 Bar Priority

    Priority Valves open only when inlet pressure reaches 230 BAR. When all banks reach 230 BAR, they fill up together until the compressor shuts off.

    230 Bar · Automatic Priority Sequence
    Feature · 06

    Solenoid Shut-Off Option

    With the addition of solenoid valves each forecourt line can be shut-off. Pre-wired into a flameproof box; solenoids close instantly when power is removed for added safety.

    Flameproof Box · Instant Shut-Off
    03
    Configurations

    Options to suit your specifications.

    A range of Priority Panel configurations with options designed to suit your specific site and operational requirements.

    01 One, Two and Three Bank Priority Panels
    02 Optional Compressor Top-UP
    03 Optional Solenoid Shut-Off Valves
    04 Optional Pressure Relief Valves
    05 Daughter Station Priority Panel
    06 Other options available on request
    04
    FAQ

    Common questions.

    Q·01 What are Priority Panels used for?
    Priority Panels are designed for testing and filling of CNG vehicles. They prioritize gas flow from multiple storage banks, ensuring vehicles are filled efficiently and cylinders are drawn down in the correct sequence.
    Q·02 What flow rates do Priority Panels support?
    The panels are designed for compressor flow rates in excess of 3,000 m³/hr, enabling ultra high flow rates for fast CNG vehicle filling.
    Q·03 What materials are used in the Priority Panels?
    All components are manufactured from high quality stainless steel SS 316 sourced from Ham-Let, Israel, ensuring maximum corrosion resistance and a long service life.
    Q·04 Are Priority Panels tested before dispatch?
    Yes. Before dispatch all Priority Panels are tested on natural gas at the in-house CNG Station. This ensures that on arrival the priority panel is ready to use and no additional on-site adjustments are required.
    Q·05 What configurations are available?
    Neometrix offers One, Two and Three Bank Priority Panels with optional Compressor Top-UP, Solenoid Shut-Off Valves, Pressure Relief Valves, and Daughter Station Priority Panel configurations. Other options are available on request.
    Q·06 How does the Solenoid Shut-Off option work?
    With the addition of solenoid valves, each of the forecourt lines can be shut-off. The solenoid comes pre-wired into a flameproof box and when power supply is removed the solenoids close instantly, providing increased safety control over gas flow through the priority panel.

    Similar Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat