200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
Priority Panels / 230 Bar · Priority Valve / SS 316 · Ham-Let Israel / CNG Vehicle Filling Neometrix · India
Priority Panels · Neometrix

CNG priority
panels.

Designed and fabricated in-house — customized Priority Panels for testing and filling of CNG vehicles. Built around an extremely reliable and robust Priority Valve with all components in SS 316 from Ham-Let, Israel.

Priority Panels — Neometrix
Fig · 01 Priority Panel — CNG vehicle filling system
Operating Pressure
230Bar
Flow Rate
3,000m³/hr+
Material
SS 316Ham-Let, Israel
Application
CNGVehicle Filling
01
Overview

Priority panels. Ready to use.

Customized Priority Panels for testing and filling of CNG vehicles, built around a proven Priority Valve and manufactured entirely from SS 316 components for maximum corrosion resistance and long service life.

Neometrix Priority Panels are designed and fabricated in-house to customer specifications for testing and filling of CNG vehicles. Each panel is designed around our own extremely reliable and robust Priority Valve. All components used in the panels are manufactured from high quality stainless steel SS 316 sourced from Ham-Let, Israel, ensuring maximum corrosion resistance and a long service life.

Before dispatch, all Priority Panels are tested on natural gas at the in-house CNG Station. This ensures that on arrival your priority panel is ready to use and no additional on-site adjustments are required.

Tested on natural gas before dispatch. Ready to use on arrival.

Priority Valves open only when inlet pressure reaches 230 BAR. Gas is then allowed to flow to the common outlets on the bottom and right hand side of the valves. When all banks reach 230 BAR, they fill up together until the compressor shuts off.

02
Key Features

Built for CNG filling.

Feature · 01

Ultra High Flow Rates

Panels are designed for compressor flow rates in excess of 3,000 m³/hr for fast and efficient CNG vehicle filling operations.

3,000+ m³/hr · High Throughput
Feature · 02

No Reverse Flow

Check valves on each line prevent reverse flow through the priority panel, protecting the storage banks and compressor at all times.

Check Valves · Reverse Flow Protection
Feature · 03

Large Flow Range — KG80 Meter

The KG80 meter is accurate over the range 1–80 kg/min and has been approved to the latest OIML standard: “Compressed Gaseous Fuel Measuring Systems for Vehicles”.

1–80 kg/min · OIML Approved
Feature · 04

Easy Maintenance

The station can be kept running while the manual isolation valves are shut for maintenance work. Pipe work does not need to be removed for servicing the panels.

In-Service Maintenance · Minimal Downtime
Feature · 05

Simple Operation — 230 Bar Priority

Priority Valves open only when inlet pressure reaches 230 BAR. When all banks reach 230 BAR, they fill up together until the compressor shuts off.

230 Bar · Automatic Priority Sequence
Feature · 06

Solenoid Shut-Off Option

With the addition of solenoid valves each forecourt line can be shut-off. Pre-wired into a flameproof box; solenoids close instantly when power is removed for added safety.

Flameproof Box · Instant Shut-Off
03
Configurations

Options to suit your specifications.

A range of Priority Panel configurations with options designed to suit your specific site and operational requirements.

01 One, Two and Three Bank Priority Panels
02 Optional Compressor Top-UP
03 Optional Solenoid Shut-Off Valves
04 Optional Pressure Relief Valves
05 Daughter Station Priority Panel
06 Other options available on request
04
FAQ

Common questions.

Q·01 What are Priority Panels used for?
Priority Panels are designed for testing and filling of CNG vehicles. They prioritize gas flow from multiple storage banks, ensuring vehicles are filled efficiently and cylinders are drawn down in the correct sequence.
Q·02 What flow rates do Priority Panels support?
The panels are designed for compressor flow rates in excess of 3,000 m³/hr, enabling ultra high flow rates for fast CNG vehicle filling.
Q·03 What materials are used in the Priority Panels?
All components are manufactured from high quality stainless steel SS 316 sourced from Ham-Let, Israel, ensuring maximum corrosion resistance and a long service life.
Q·04 Are Priority Panels tested before dispatch?
Yes. Before dispatch all Priority Panels are tested on natural gas at the in-house CNG Station. This ensures that on arrival the priority panel is ready to use and no additional on-site adjustments are required.
Q·05 What configurations are available?
Neometrix offers One, Two and Three Bank Priority Panels with optional Compressor Top-UP, Solenoid Shut-Off Valves, Pressure Relief Valves, and Daughter Station Priority Panel configurations. Other options are available on request.
Q·06 How does the Solenoid Shut-Off option work?
With the addition of solenoid valves, each of the forecourt lines can be shut-off. The solenoid comes pre-wired into a flameproof box and when power supply is removed the solenoids close instantly, providing increased safety control over gas flow through the priority panel.