200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Neometrix / Acoustic Emission Test Systems / Acoustic Emission Test Station / NMX-AET-109
    NMX-AET-109 · ENGINEERED-TO-ORDER CLASS — DUTY · QUIET PRESSURISATION · SENSORS · LISTENING · LOCATING · BUILD · PROVE

    Acoustic Emission Test Station. A flaw speaks when loaded.

    An acoustic emission test station pressurises a gas cylinder or a pressure vessel and listens to its wall while the pressure rises. A flaw that is growing gives off short bursts of stress wave, and sensors on the wall hear them and say where they came from. Neometrix engineers the station as a whole: the cell, the quiet pressurisation, the sensor fixtures, the controls and the proof.

    So the station has to know that a flaw speaks only while it is loaded, raise the pressure in slow steps, and keep its own noise out of the record.

    An acoustic emission test station on a plain white studio background: a pale grey steel test cell on legs with a clear guard door standing open on the left, a long pale grey gas cylinder lying on two black padded cradles inside it, four small bright steel sensors held along the cylinder by black straps with thin cables running down to a pale grey cabinet on castors, and black hoses from the cylinder valve to a pressurisation skid on the right with a black pump, a bright steel accumulator and a ball valve with a red handle, and no people
    Fig · 01 — An acoustic emission test station: a gas cylinder on padded cradles in a cell with a glass door, four sensors on its wall, a cabinet beside the cell and a pressurisation skid on the right — illustrative render.
    The pressure
    rises in stepsslow enough to hear each one
    The pump
    is shut off to listenits noise stays out of the record
    The sensors
    are tried before the runa pencil-lead break at each one
    The sound
    is placed on the wallfrom the arrival times
    Status
    engineered to orderno delivery is claimed
    ISO 9001ISO 14001ASTM E1419 reference for gas-filled pressure vessels
    01
    Overview

    What an acoustic emission test has to get right, and what goes wrong when it does not.

    Because the sound of a growing flaw is small, the noise of the pressurisation is loud by comparison, and a record that cannot place the sound is of little use.

    A long pale grey gas cylinder lying on two black padded cradles on a plain white studio background, with a bright steel valve at its left end and three small bright steel cylindrical sensors held against its wall by black straps, each with a thin black cable running down to a small pale grey preamplifier box on the floor, the three boxes joined by one grey cable that leaves to the right, and no people
    Fig · 02 — Sensors on a cylinder wall: three small sensors held by straps, each with its own preamplifier box, and one cable leaving to the right — illustrative render.

    A flaw speaks only while it is loaded.

    What the station is for

    It pressurises a cylinder or a vessel above its normal working pressure and listens to the wall while the pressure rises. It finds where a flaw is growing, so that a person can look at that place with a second method.

    Why a flaw speaks only while it is loaded

    A crack that does not grow makes no sound. When the load rises and the crack grows by a very small step, the metal gives off a short burst of stress wave, and the burst runs through the wall to the surface. A sensor there hears it. Take the load away and the flaw is quiet again.

    Why the pressure must go higher than before

    A sound vessel stays quiet until the load passes the highest it has seen before. This is the Kaiser effect. So the test goes above the normal working pressure, and a second test too soon after the first is less sensitive. Where there is damage, emission can start earlier than that, and this is the Felicity effect.

    Why the station must be quiet

    A pump, a valve, a fitting that weeps and a vessel that rubs on its cradle all make noise, and some of it looks like a flaw. So the pressure is raised slowly, the pump is shut off during a hold, the cradles are padded, and the noise of the room is measured before the test begins.

    Why the sound is placed

    A burst reaches each sensor at a slightly different time. Because the speed of the wave in the wall is known, the differences place the source on the wall. The sensors are spaced from a measurement of how far the wave carries, and each one is checked with a pencil-lead break before the run.

    What it can and cannot tell

    It tells where to look. It does not tell what the flaw is, and it does not pass or fail a vessel. A second examination of the places it finds, by a competent person, does that.

    Why a listening station is not for every job

    It is not a requalification line, which measures how much a cylinder swells under water pressure. It is not an ultrasonic scanner, which probes a part at rest. The duty states the vessels, the pressures and the follow-up, and the station is built for that.

    02
    The method

    Duty, quiet pressurisation, sensors, listening, locating, build and prove.

    Six steps in a fixed order. The quiet and the sensor check are the two that a quick job skips.

    1 · Duty

    The vessels, the pressure they must reach, the follow-up examination and the room are noted, with the services the station has and the people who work near it.

    2 · Quiet pressurisation

    The skid raises the pressure in slow steps and shuts the pump off during a hold, so that its noise cannot pass for a flaw.

    3 · Sensors

    The sensors are spaced from the measured decay of the wave, held on their mounts, and each one is tried with a pencil-lead break.

    4 · Listening

    Preamplifiers, filters and guard channels pass the small signals, and the pressure is recorded with every sound that is heard.

    5 · Locating

    The arrival times place each source on the wall, the sounds are sorted into clusters, and the places that speak are handed to a second examination.

    6 · Build and prove

    The station is built and tried, a reference vessel with a known source is run, every trip is tested, and the record goes with the station.

    Which fault, which safeguard

    What can go wrongWhy it happensWhat the station does about it
    The test hears the pump, not the flawthe pump and the valves make noise while the pressure risesslow steps, a pump that is shut off during a hold, and a background run before the test
    A flaw is heard but not placedthe sensors are too few or too far apart for the wave to carrysensor spacing set from a measurement of how far the wave carries, and arrival times recorded
    A sensor is not hearingthe coupling is poor or a cable is faultya pencil-lead break at every sensor before and after the run, with the result kept
    The vessel is silent when it should not beit was not loaded above the highest load it has seena test pressure above the normal working pressure, and a rest between runs
    A leak sounds like a flawa weeping fitting gives a steady hiss that fills the recorda leak check at low pressure first, and software that tells a steady hiss from a burst
    The sounds pile upthe pressure rises too fast for the sounds to be told aparta controlled rate set by the procedure, and a log of the pressure with every sound
    A sign is read as a verdictthe method tells where to look and not what the flaw isthe places that speak are handed to a second examination by a competent person, and the record says so
    Someone is near a pressurised vessela guard is opened while the pressure is upa closed cell, interlocks, a control room outside, and a procedure that says nobody stands near a pressurised vessel

    The step people underrate is the quiet. A station looks the same whether its pump is shut off during a hold or left running, and only one of them gives a record that can be trusted.

    03
    Work content

    What the station contains, element by element.

    Read it as a checklist: a station missing a row will pressurise a vessel, but it will not give a record that places a flaw.

    The quiet pressurisation skid of an acoustic emission test station on a plain white studio background: a pale grey steel frame on four black rubber feet holding a small black pump with a bright steel head, a bright steel accumulator standing upright, a ball valve with a red handle between the pump and the accumulator, a small relief valve, a bright steel pressure transducer body, a drain valve and braided steel hoses, and no people
    Fig · 03 — The pressurisation skid: a pump, an accumulator and a ball valve between them, with a relief valve, a transducer and braided hoses — illustrative render.
    ElementWhat it doesWhat matters
    Test cellkeeps people clear and the noise outa closed cell with a guard door and interlocks, on a floor that does not carry the noise of the room into the vessel
    Cradles and clampshold the vessel quietlypadded cradles that carry the vessel without rubbing, and clamps that do not creak as the pressure rises
    Pressurisation skidraises the pressure in stepsa low-noise pump, an accumulator and an isolation valve, so that the pump can be shut off during a hold
    Fill and ventfills the vessel and clears the aira fill line, a high vent and a drain, because trapped air stores energy and adds noise
    Relief and safety deviceslimit the pressurerelief valves set above the test pressure, and an emergency vent that works apart from the controller
    Pressure transducersrecord the pressurea transducer that is read with every sound that is heard, and a second one for the trip
    Sensors and mountshear the wallresonant sensors on held mounts with a couplant, spaced from the measured decay of the wave
    Preamplifiers and cablingcarry the small signalpreamplifiers close to the sensors, screened cable and one clean ground
    Acquisition and softwaredetect, place and sort the soundsa chassis that records every sound with its time, its size and its pressure, with guard channels, location and a log
    Sensor checkproves every sensor hearsa pencil-lead break at each sensor before and after the run, and the result kept with the record
    Controllerruns the pressure stepssteps, holds and rate set by the customer's procedure, with trips that work apart from the controller
    Testing & documentationprove the station firsta reference vessel with a known source, every trip tried, and a record the customer can inspect

    The elements that decide the result are the isolation valve and the sensor check. The first keeps the pump out of the record, and the second shows that every sensor was hearing when the sounds came.

    Full specification — expand
    SystemA test cell with a guard door and interlocks; padded cradles; a low-noise pressurisation skid with an isolation valve so that the pump can be shut off during a hold; a fill, vent and drain line; relief and safety devices; pressure transducers; resonant sensors on held mounts with preamplifiers and screened cable; an acquisition chassis and software that records, places and sorts every sound; a pencil-lead break check of every sensor; a controller that runs the pressure steps; and a proving run on a reference vessel, a trip check and documentation before handover
    The One IdeaA flaw speaks only while it is loaded.
    Why A Flaw Speaks Only While It Is LoadedA crack that does not grow makes no sound. When the load rises and the crack grows by a very small step, the metal gives off a short burst of stress wave that runs through the wall to the surface, where a sensor hears it. Take the load away and the flaw is quiet again
    Why The Pressure Must Go Higher Than BeforeA sound vessel stays quiet until the load passes the highest it has seen before, which is the Kaiser effect, so the test goes above the normal working pressure. Damaged material can emit before that point, which is the Felicity effect
    StandardsASTM E1419 covers acoustic emission examination of seamless gas-filled pressure vessels. ISO 16148 covers acoustic emission and follow-up ultrasonic examination of refillable seamless steel gas cylinders and tubes. EN 14584 covers acoustic emission examination of metallic pressure equipment during proof testing. ASTM E976 covers the reproducibility of sensor response. This page prints none of their requirements, and no edition year. Approval of a vessel rests with the customer and the authority they name; none is claimed here
    ConfigurationsA cylinder test cell, a portable in-situ set, and a vessel and pipework set
    Scope BoundaryThis page is the acoustic emission test station, which listens to a vessel while it is loaded and places what it hears. It is not a non-destructive testing and inspection system, which is the active methods that probe a part at rest (see non-destructive testing and inspection system), not a requalification line, which measures how much a cylinder swells under water pressure (see HP air bottle test and requalification facility) and not an expansion test machine, which measures that swelling automatically (see automatic volumetric expansion test system). It does not certify a vessel, and it does not replace the operator's own judgement. No certification or accreditation is claimed here
    StatusNeometrix engineers acoustic emission test stations to order, and no delivered acoustic emission test station is claimed.
    04
    Configurations

    One method, three ways to build the station.

    The method, the quiet and the sensor check are shared. What changes is where the vessel is, how many sensors the wall needs, and what raises the pressure.

    Cylinder test cell

    A fixed cell for cylinders out of service

    For cylinders that come to a test house: a guarded cell, padded cradles, a quiet pressurisation skid and a fixed set of sensors, so that each cylinder is loaded and listened to in the same way.

    Portable in-situ set

    For cylinders left where they are

    For cylinders fitted to a system or standing in a bank: a portable set that is carried to the cylinders, loaded in steps from the system's own supply, with the supply shut off during each hold.

    Vessel and pipework set

    More channels, a wider wall

    For larger pressure vessels and long runs of pipe: more channels, sensors laid out over a wide area, and software that places each source on the surface in a plane.

    And the part that is not equipment at all, yet decides all three: the procedure. It is taken from the customer's own rules and the standard they name, not from the station.

    05
    The drawings

    A reference set, drawn as real CAD sheets.

    Two sheets of one reference configuration: the arrangement of an acoustic emission test station with three details, and its signal and protection chains with the curves that show why a flaw speaks only while it is loaded. They show the cell, the sensors and the quiet hold, and how a sound is placed on the wall. They carry tags and letters only. Every pressure, rate, time and size is fixed by design for the customer's duty.

    Reference drawing sheet one, the arrangement and details of an acoustic emission test station. A plan shows the cylinder test cell: a guarded cell with a door that swings open and an interlock, a cylinder on two padded cradles with four sensors along its top, each with a preamplifier, one cable bus out of the cell to an acquisition cabinet and a controller in the control room, and a pressurisation skid outside the cell with a pump, an isolation valve, an accumulator, a transducer and an emergency vent, with a fill line through the wall to the cylinder valve. Letters mark the length of the cylinder and the spacing of the sensors. Detail A shows a sensor on the wall with its couplant, its clip and spring and its preamplifier. Detail B shows the quiet hold, with the pump off and the isolation valve closed. Detail C shows the padded cradle. An item list numbers seven parts. A title block stamped reference configuration, not for construction
    Fig · 04 — Sheet 01, the arrangement: the cylinder test cell in plan, the sensor on the wall, the quiet hold and the padded cradle. Reference configuration, letters only.
    Reference drawing sheet two, the signal and protection chains and the curves of an acoustic emission test station. A signal chain runs from the sensors through the preamplifiers and a filter into the hit detection, which records every hit with the pressure from a transducer, then places each hit on the wall, sorts the hits into clusters and keeps the record, with a guard channel to reject noise. A protection chain shows an independent trip that takes a second transducer and the door interlock, stops the pump and opens the vent without asking the controller. Detail A is a computed plot of the pressure steps against time, with the pump on in the ramps and off in the holds and the hits of a growing flaw below. Detail B is a computed plot of the Kaiser effect: a sound wall stays quiet until the highest pressure seen before, and a damaged wall emits early. Detail C shows linear location, where two sensors and the difference in arrival time place a source on the wall. A title block stamped reference configuration, not for construction
    Fig · 05 — Sheet 02, the signal and protection chains and the curves: the pressure steps, the Kaiser effect and the linear location. Reference configuration, tags only.

    Every real station is drawn for its own vessels, its own procedure and its own room. These sheets are the arrangement and the order of working that a project set starts from. Approval of any drawing rests with the customer and the authority they name; none is claimed here.

    06
    Where it is used

    Wherever a pressure vessel has to be checked without being cut open, and trusted afterwards.

    The common thread is a vessel that holds a high pressure, a flaw that cannot be seen from outside, and a decision that has to be shown and not guessed.

    Cylinder test houses

    Where cylinders come in for periodic inspection, and a listening test picks out the ones that need a closer look.

    Gas storage operators

    Where banks of cylinders and long runs of pipe cannot all be taken out of service to be tested one by one.

    Pressure vessel makers

    Where a new vessel is proof tested, and the test is listened to as well as watched on a gauge.

    Research laboratories

    Where a new material, a wrapped cylinder or a new design is loaded and the sounds it makes are studied.

    07
    Watch

    See it in motion.

    A short walkthrough video of the acoustic emission test station.

    08
    FAQ

    Common questions.

    Longer answers, for readers who want the reasoning.

    Q · 01 What does an acoustic emission test station actually do?
    It pressurises a gas cylinder or a pressure vessel and listens to its wall while the pressure rises. The vessel is held on padded cradles in a guarded cell, filled with water and cleared of air, and loaded in slow steps by a quiet skid. Sensors on the wall hear the short bursts of stress wave that a growing flaw gives off, and the acquisition chassis records each one with its time, its size and the pressure at that moment. The arrival times place the source on the wall. The station does not decide whether a vessel is fit. It finds the places that speak, and a second examination by a competent person looks at them. The station does not choose the procedure either; that comes from the customer's own rules, and the station is built, proved and recorded to carry it out.
    Q · 02 Why does a flaw speak only while it is loaded?
    Because the sound comes from the flaw changing, and a flaw that is not changing is silent. When the load rises, the metal at the tip of a crack can give way by a very small step, and the sudden release of energy runs outward as a short burst of stress wave. Hold the load steady and nothing moves, so nothing is heard. A sound vessel also stays quiet until the load passes the highest it has seen before, which is the Kaiser effect, so a test has to go above the normal working pressure, and a second test too soon after the first is less sensitive. Where the material is damaged, emission can start before the old maximum is reached, which is the Felicity effect, and that early start is itself a sign.
    Q · 03 How is a sound placed on the wall?
    By the difference in arrival time. A burst reaches the nearer sensor first and the farther one a little later, and because the speed of the wave in the wall is known, the difference puts the source on a line between two sensors. With more sensors the source is placed on the surface. For this to work the sensors cannot be too far apart for the wave to carry, so their spacing is set from a measurement of how far the wave travels in that wall, made with a pencil-lead break. The same break, made at each sensor before and after the run, shows that every sensor was hearing. A sensor that did not hear the break cannot be trusted to have heard the flaw.
    Q · 04 Why does the pump have to be kept quiet?
    Because the sound of a growing flaw is small and the sound of a pump is large. A pump, a valve, the flow in a hose and a fitting that weeps all make noise, and some of that noise looks like a flaw to the software. A vessel that rubs on its cradle does the same. So the station raises the pressure slowly, uses a low-noise pump, and puts an isolation valve and an accumulator between the pump and the vessel, so that the pump can be shut off while the pressure is held and the vessel is listened to in silence. The noise of the room is measured before the test begins, and guard channels help to tell what is outside the vessel from what is in it.
    Q · 05 Is this the same as an inspection system, a requalification line or an expansion test machine?
    No, and the differences are worth stating precisely. The non-destructive testing and inspection system page covers the active methods, which send radiation, sound or current into a part at rest and read what comes back. The HP air bottle test and requalification facility page covers a line that measures how much a cylinder swells under water pressure, with the surface cleaning, the valve handling and the recharge around it. The automatic volumetric expansion test system page covers the machine that measures that swelling. This page is the station that listens to a vessel while it is loaded and places what it hears. It does not replace any of them, and it does not claim what they claim a second time.
    Q · 06 Has Neometrix built one of these?
    We would rather answer this plainly than let a page imply otherwise. Neometrix engineers acoustic emission test stations to order, and no delivered acoustic emission test station is claimed. What stands behind the offer is adjacent: Neometrix engineers an HP air bottle test and requalification facility (see the HP air bottle test and requalification facility page), an automatic volumetric expansion test system (see the automatic volumetric expansion test system page) and a non-destructive testing and inspection system (see the non-destructive testing and inspection system page). The sensors, the preamplifiers, the acquisition chassis and the analysis software are catalogue items from acoustic emission specialists, bought in, not invented. What Neometrix engineers is the station around them: the cell, the cradles, the quiet pressurisation, the fixtures, the controls and the proof. So the honest position is that the station is engineered to order, the neighbouring disciplines are in the building, and the first station of this exact kind will be built around the customer's own vessels rather than taken off a shelf.
    Q · 07 Which standard applies, and what can the station not do?
    ASTM E1419 covers acoustic emission examination of seamless gas-filled pressure vessels. ISO 16148 covers acoustic emission and follow-up ultrasonic examination of refillable seamless steel gas cylinders and tubes. EN 14584 covers acoustic emission examination of metallic pressure equipment during proof testing, and ASTM E976 covers the reproducibility of sensor response. This page prints none of their requirements, and no edition year: those come from the standard and the authority the customer names. The station loads a vessel, listens and records what it heard. It does not certify a vessel, it does not tell what a flaw is, and it does not replace the operator's own judgement about who is near a pressurised vessel and when. This page claims no certification or accreditation. No pressure, rate, time, frequency or distance figure is printed here, and approval of a vessel rests with the customer and the authority they name; none is claimed here.
    Q · 08 What do you need from us to quote?
    Six things, and most of them describe your vessels rather than the station. First, the vessels: what they are, how they are made, and whether they stay in place or come to a cell. Second, the pressure: the working pressure and the test pressure the procedure asks for. Third, the procedure: the standard or the rule it comes from, and what is done with the places that speak. Fourth, the throughput: how many vessels in a day. Fifth, the room: what services it has, and how quiet it is. Sixth, the record: whether a proving run and a test record are needed. From that we come back with a station concept, a proving plan you can check, and a budgetary price.
    09
    Related

    The neighbouring pages, and how they differ from this one.

    Three neighbours: one probes a part at rest, one measures how much a cylinder swells, and one is the machine that does that measuring.

    Browse all Neometrix product lines.

    Get a quotation

    Tell us the vessels,
    and the pressure they must reach.

    The projects desk replies within two working days with a station concept, a proving plan you can check, and a budgetary quotation. Write to [email protected] or use the form.

    Enquire — acoustic emission station Capability sheet (PDF) +91 7777 876 876
    ISO 9001 / 14001 ENGINEERED-TO-ORDER CLASS — ACOUSTIC EMISSION TEST STATION DUTY · QUIET PRESSURISATION · SENSORS · LISTENING · LOCATING · BUILD · PROVE — A FLAW SPEAKS ONLY WHILE IT IS LOADED. ENGINEERED IN NOIDA · INDIA

    Trending Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat
    move to top arrow