200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Neometrix / Materials Testing Machines / Creep and Stress-Rupture Test Machine / NMX-CRP-112
    NMX-CRP-112 · ENGINEERED-TO-ORDER CLASS — DUTY · FRAME AND LEVER · FURNACE AND TEMPERATURE · STRAIN AND ALIGNMENT · CLOCK AND LOG · BUILD · PROVE

    Creep Test Machine. A creep test is only as steady as its furnace.

    A creep test holds a metal specimen under a steady pull at a high temperature for a long time, and records how it stretches until it breaks or the test is stopped. Neometrix engineers the machine that does it as a whole: the loading frame, the furnace, the strain record and the clock.

    So the machine has to know that a creep test is only as steady as its furnace, keep the pull truly constant while the specimen stretches, and never lose the clock.

    A creep test machine on a plain white studio background: a tall pale grey steel floor frame with a long horizontal lever arm across the top, a stack of plain unmarked round steel discs hanging from the far end of the lever, a bright steel pull-rod train running down the middle of the frame through a split cylindrical furnace with a pale grey casing, a small black transducer on a stiff bracket beside the furnace, a small pale grey control cabinet at the side with a thin black cable to the frame, and no people
    Fig · 01 — A creep test machine: a lever arm with dead weights above a split furnace on a pull-rod train, with its control cabinet — illustrative render.
    The furnace
    decides the answera small drift moves the whole curve
    The pull
    stays constantthe lever is held level as the specimen stretches
    The strain
    is read at the specimennot at the frame, which also moves with the room
    The clock
    is never lostit stops at the break, and a power cut is on the record
    Status
    engineered to orderno delivery is claimed
    ISO 9001ISO 14001Test conditions set by the customer and the method they follow
    01
    Overview

    What a creep test has to get right, and what goes wrong when it does not.

    Because a creep test runs for such a long time, a small fault does not show up as one bad reading. It shows up as a curve that is quietly wrong, from a test that cannot be repeated cheaply.

    The heart of a creep test machine on a plain white studio background: a pale grey hinged furnace casing opened like a book, both halves lined with pale cream insulation, a slim bright steel round bar standing upright in the right half with a round ball joint at each end and one near each end, three thin pale wires tied along the bar and leading out towards the lower left, two thin white ceramic rods running from the bar to a small black transducer on a bracket at the right side of the casing, and no people
    Fig · 02 — The specimen in its furnace: thermocouples along the bar, and the rods that carry its stretch out to the transducer — illustrative render.

    A creep test is only as steady as its furnace.

    What the machine is for

    It holds a round bar, the specimen, under a steady pull at a high temperature, and records how it stretches with time. A stress-rupture test is the same test pushed to the break, and only the time to break is kept.

    The three stages

    The stretch has three stages. At first the rate of stretch falls. Then it is nearly steady for most of the life. At the end it climbs until the specimen breaks. The steady rate and the time to break are what a designer reads.

    Why the furnace is the instrument

    The creep rate climbs steeply with temperature. A small error, or a slow drift, in the temperature of the specimen therefore becomes a large error in the rate and in the time to break. The pull can be worked out on paper. The temperature has to be held, and measured on the specimen itself.

    Why the pull must stay constant

    Dead weights hang from a lever, and the lever multiplies them into a pull on the specimen. As the specimen stretches, the lever tilts and the multiplication changes, so a drive keeps the lever level and the pull constant.

    Why the strain is hard to read

    The stretch is tiny, and the frame and the room swell and shrink with the day and the season by amounts that are not tiny beside it. So the strain is read from the specimen's own shoulders, through rods that leave the furnace, and the room, the rods and the transducer are kept quiet.

    Why the pull must be on the axis

    Any bending adds stress to one side of the bar. The load train uses knife edges or ball seats so that the pull runs along the axis, and the alignment is checked on a specimen carrying strain gauges.

    Why the clock is never lost

    A test can last for months, and the clock is the test. It starts when the specimen is loaded at temperature and stops at the break. A power cut, a lost record or a furnace that wandered cannot be repaired afterwards, so each is guarded against and written down.

    Why a creep test is not another test

    It is not a universal testing machine, which pulls a specimen to break in a short test, and not a fatigue testing machine, which cycles the load. It is a long hold at a steady pull and a steady temperature.

    02
    The method

    Duty, frame and lever, furnace and temperature, strain and alignment, clock and log, build and prove.

    Six steps in a fixed order. The furnace and the temperature survey are the two that a quick job skips.

    1 · Duty

    The metals and specimen shapes to be tested, the temperatures and pulls that matter, whether the strain or only the time to break is wanted, how many stations, the room and the services, are noted.

    2 · Frame and lever

    A stiff frame carries a lever arm and its dead weights, with a drive that holds the lever level, so that the pull stays constant as the specimen stretches.

    3 · Furnace and temperature

    A furnace with several zones surrounds the specimen, with thermocouples tied to the specimen itself, so that the temperature that is held is the temperature the specimen has.

    4 · Strain and alignment

    Rods from the specimen's shoulders carry its stretch out of the furnace to a transducer on a quiet mount, and the load train keeps the pull on the axis.

    5 · Clock and log

    A logger keeps the strain, the temperatures and every event, with a clock that starts when the test starts, stops at the break and survives a power cut.

    6 · Build and prove

    The machine is built and its pull is checked, the temperature along a dummy specimen is surveyed, the alignment is checked on a gauged specimen, every cut-out is tried, and the record goes with the machine.

    Which fault, which safeguard

    What can go wrongWhy it happensWhat the machine does about it
    The rate is wrong though the pull is rightthe specimen's temperature drifted, or the thermocouple read the furnace and not the specimenthermocouples tied to the specimen along its gauge length, a furnace with several zones, and a temperature log kept with every curve
    The pull changes as the specimen stretchesthe lever tilted, and the multiplication changed with ita drive that holds the lever level, and a check of the pull with a load cell before the first test
    The strain drifts with the weatherthe frame or the room changed temperature, and the transducer moved with ita transducer on a stiff, quiet mount, rods that reach the specimen's shoulders, and a record of the room temperature beside the strain
    The specimen bends as well as stretchesthe pull was not along the axis of the barknife edges or ball seats in the load train, and an alignment check on a gauged specimen
    The clock is wrongit started before the temperature had settled, or a power cut went unrecordeda rule that starts the clock only when the load is on and the temperature has settled, a clock that survives a cut, and a log of every event
    The test runs on after the breaknothing told the machine that the specimen had faileda break switch that stops the clock and the furnace, and a stop that catches the falling weights
    The furnace goes wrong with no one therea controller fault or a failed element on a test that runs day and nightan independent over-temperature cut-out, an alarm to the person on duty, and a record of what happened and when
    Someone is hurt by a weight or a hot surfacethe weights hold stored energy and the furnace is hotguards round the lever and the furnace, a stop that holds the weights, and a cool outer casing

    The step people underrate is the temperature survey. A machine whose furnace was never measured along a dummy specimen cannot say what temperature the specimen really had.

    03
    Work content

    What the machine contains, element by element.

    Read it as a checklist: a machine missing a row will still pull a specimen hot, but it will not give a curve that can be trusted and compared.

    A bank of creep test machines on a plain white studio background: three identical tall pale grey steel floor frames standing side by side, each with a long horizontal lever arm across the top, a stack of plain unmarked round steel discs hanging from the far end of each lever and a small pale grey cylindrical furnace casing midway down, with a thin black cable from each casing running along the floor to a plain pale grey logging cabinet at the right, and no people
    Fig · 03 — A bank of stations on one logger: the same frame, repeated — illustrative render.
    ElementWhat it doesWhat matters
    Loading framecarries the load traina stiff frame on a quiet foundation, with room for the lever and the furnace and a way to change a specimen
    Lever arm and weightsmake the pulla lever of known multiplication, hung with plain dead weights that can be added or taken off, and checked against a load cell
    Levelling drivekeeps the pull constanta drive that senses the tilt of the lever and takes up the stretch of the specimen, so that the lever stays level
    Load train and gripscarry the pull to the specimenpull rods with knife edges or ball seats and grips that hold a threaded or shouldered specimen on the axis
    Furnaceheats the specimena split furnace with several zones, so that the specimen has the same temperature along its length, with a casing that stays cool outside
    Temperature sensors and controlhold and read the temperaturethermocouples tied to the specimen, an independent controller for each zone, and a log of the temperatures with the strain
    Extensometer and transducerread the stretchrods that touch the specimen's shoulders and leave the furnace, and a transducer on a stiff, quiet mount, kept apart from the heat
    Break switch and weight stopend the test safelya switch that sees the break and stops the clock and the furnace, and a stop that catches the weights
    Logger and clockkeep the recorda logger that stores the strain, the temperatures and every event, with a clock that survives a power cut
    Guards and cut-outsprotect people and the testguards round the lever and the furnace, an independent over-temperature cut-out, and an alarm to the person on duty
    Testing & documentationprove the machine firsta pull check against a load cell, a temperature survey on a dummy specimen, an alignment check on a gauged specimen, every cut-out tried, and a record the customer can inspect

    The elements that decide the result are the furnace and its thermocouples and the levelling drive. The first makes the temperature known, and the second keeps the pull what it was said to be.

    Full specification — expand
    SystemA loading frame with a lever arm and dead weights, a drive that holds the lever level and a load train with knife edges or ball seats; a furnace with several zones and its controller; thermocouples on the specimen; an extensometer with rods that leave the furnace and a transducer on a quiet mount; a break switch and a stop for the weights; a logger and clock that survive a power cut; guards and an independent over-temperature cut-out; and a proving run, a temperature survey and documentation before handover
    The One IdeaA creep test is only as steady as its furnace.
    Why The Furnace DecidesThe creep rate climbs steeply with temperature, so a small error or drift in the specimen's temperature becomes a large error in the rate and in the time to break
    Why The Load Must Stay ConstantA lever multiplies the dead weights into the pull. As the specimen stretches, the lever tilts and the multiplication changes, so a levelling drive keeps the lever level
    Why The Clock MattersA test can last for months, and the clock is the test. It starts when the load is on and the temperature has settled, it stops at the break, and a power cut is on the record
    StandardsThe method is described in ISO 204 and ASTM E139; the guides for thermocouples and for alignment are ASTM E633 and ASTM E1012. The conditions to be reproduced are stated by the customer, and approval of a result rests with the customer and the authority they name; none is claimed here. No certification or accreditation is claimed here
    ConfigurationsA creep frame, a stress-rupture bank, and an impression creep station
    Scope BoundaryThis page is the creep and stress-rupture test machine, which holds a metal specimen under a steady pull at a high temperature for a long time. It is not a universal testing machine, which pulls a specimen to break in a short test (see universal testing machine), not a fatigue testing machine, which cycles the load (see servo-hydraulic fatigue testing machine), not a pipe pressure tester, which holds a steady internal pressure on pipe (see pipe hydrostatic pressure tester) and not a hydrogen embrittlement test system, which holds a sustained load in hydrogen (see hydrogen embrittlement test system). It does not certify a metal, and it does not replace the operator's own judgement
    StatusNeometrix engineers creep and stress-rupture test machines to order, and no delivered creep test machine is claimed.
    04
    Configurations

    One method, three ways to build the machine.

    The method, the temperature survey and the clock rule are shared. What changes is what is recorded, how many specimens run at once and how large the specimen is.

    Creep frame

    A strain record for one specimen

    For measuring the stretch: a lever-arm frame with a levelling drive, a furnace with several zones, thermocouples on the specimen, extensometer rods and a transducer, and a logger that records the curve with its temperatures.

    Stress-rupture bank

    Time to break, several at once

    For finding how long a specimen lasts at a set pull and temperature: simpler stations in a row, each with its own furnace and break switch, one clock and one log for the bank, and no strain record.

    Impression creep station

    A small flat punch on a small sample

    For metal too small or too awkward for a round bar, such as a weld or a thin section: a flat-ended punch pressed into the surface under a steady load in a small furnace, with the depth of the impression recorded against time.

    And the part that is not equipment at all, yet decides all three: the conditions. The metals, the pulls and the temperatures come from the customer's duty, not from the machine.

    05
    The drawings

    A reference set, drawn as real CAD sheets.

    Two sheets of one reference configuration: the arrangement of a creep frame with three details, and its heat, protection and measurement circuits with the curves that show why a creep test is only as steady as its furnace. They show the lever, the furnace and the load train, and how a small step in temperature changes the rate. They carry tags and letters only. Every temperature, pull, strain and time is fixed by design for the customer's duty.

    Reference drawing sheet one, the arrangement and details of a creep test machine. An elevation shows a loading frame with a lever arm on a pivot, a stack of dead weights hanging from the far end of the lever, a pull rod through a furnace to a specimen held between grips with ball seats, a levelling drive under the lower rod, a level sensor on the lever, a transducer on a bracket with two rods to the specimen's shoulders, a weight stop with a break switch, a junction box, and a control cabinet holding a controller, a logger, a cut-out, a backup supply, a heater power unit and an alarm. Detail A shows the load train and the specimen in section, with the furnace's three zones, three thermocouples on the gauge length and the two extensometer rods. Detail B shows the lever level and tilted. Detail C shows the weights falling onto the stop at the break. An item list numbers nine parts. A title block stamped reference configuration, not for construction
    Fig · 04 — Sheet 01, the arrangement: the frame, the lever, the furnace with its three zones, the levelling and the break. Reference configuration, letters only.
    Reference drawing sheet two, the circuits and the curves of a creep test machine. A circuit shows a controller driving a heater power unit through a contactor to the three zones of a furnace, zone thermocouples closing the loop, an over-temperature cut-out with its own thermocouple and a break switch opening the contactor, and a logger on its own backup supply recording the specimen thermocouples, the strain, the room temperature, a pull check and the break, with an alarm. Detail A is a computed plot of strain against time at two nearly equal temperatures: the same curve, with the hotter one run faster so that it breaks sooner. Detail B is a computed plot of the steady creep rate against a small step in temperature, rising steeply. Detail C is a computed plot of time to break against pull on log axes, with the points of a stress-rupture bank at two temperatures. A title block stamped reference configuration, not for construction
    Fig · 05 — Sheet 02, the circuits and the curves: the furnace control and its protection, and why a small step in temperature is a large step in rate. Reference configuration, tags only.

    Every real machine is drawn for its own metals, its own temperatures and its own room. These sheets are the arrangement and the order of working that a project set starts from. Approval of any drawing rests with the customer and the authority they name; none is claimed here.

    06
    Where it is used

    Wherever a metal has to carry a load at a high temperature for years, and the answer has to be measured.

    The common thread is a part that will be hot and loaded for a very long time, and a life that cannot be guessed from a short test.

    Materials laboratories

    Where alloys are ranked and the long-time behaviour of a metal has to be measured and not assumed.

    Alloy and component makers

    Where a new alloy, a casting or a forging is tested for long life at temperature before it is put to work.

    Life-assessment groups

    Where a part that has run for years is sampled, and a specimen cut from it is tested to estimate how much life is left.

    Weld and repair development groups

    Where a weld or a repair is the weak link, and a small sample from that zone has to be tested.

    07
    Watch

    See it in motion.

    A short walkthrough video of the creep test machine.

    08
    FAQ

    Common questions.

    Longer answers, for readers who want the reasoning.

    Q · 01 What does a creep and stress-rupture test machine actually do?
    It holds a metal specimen under a steady pull at a high temperature and watches what happens over a long time. A lever with dead weights makes the pull, a drive keeps the lever level as the specimen stretches, and a furnace with several zones holds the temperature. In a creep test the stretch is recorded against time, so the curve shows the three stages of creep: a falling rate, a nearly steady rate and a rising rate that ends at the break. In a stress-rupture test only the time to break is kept, which makes the machine simpler and lets several run in a row. A logger keeps every run, and the clock stops at the break. The machine does not choose the test. That comes from the customer's own duty, and the machine is built, proved and recorded to carry it out.
    Q · 02 Why is the furnace the instrument?
    Because the creep rate climbs steeply with temperature. Heat helps atoms move, and the movement is what lets the metal stretch, so a specimen that is a little hotter creeps noticeably faster and breaks sooner. A small error in the temperature of the specimen, or a slow drift over the months of a test, therefore becomes a large error in the rate and in the time to break. The pull can be worked out on paper, but the temperature has to be held and measured on the specimen itself. So the furnace has several zones, the thermocouples are tied to the specimen, and the machine is proved with a temperature survey along a dummy specimen before it is used. The published guide for thermocouples in creep testing says the same thing: creep properties are highly sensitive to temperature, and control has to be stable.
    Q · 03 Why must the pull stay constant, and how does a lever do that?
    Because the whole test assumes one pull for its whole life. A lever lets modest dead weights make a large pull, and it does so by a fixed multiplication. That multiplication holds only while the lever is level. As the specimen stretches, the end of the lever moves and the lever tilts, so a drive senses the tilt and takes up the stretch, keeping the lever level. The pull is checked against a load cell before the first test, and the dead weights are plain and can be added or taken off. Which pull a test should use, and for how long, is for the customer's duty to say. The machine keeps it what it was said to be.
    Q · 04 Why is the strain read at the specimen and not at the frame?
    Because the stretch of a specimen is tiny, and the parts around it change by amounts that are not tiny beside it. The frame, the pull rods and the room all swell and shrink with temperature, and a reading taken from the moving parts of the frame includes all of that. So rods rest on the specimen's own shoulders and carry its stretch out of the furnace to a transducer on a stiff, quiet mount, and the temperature of the room is recorded beside the strain. The load train also keeps the pull on the axis, using knife edges or ball seats, because a bent specimen stretches more on one side and the reading then depends on where it was taken. The guide for alignment describes how to check this on a specimen carrying strain gauges.
    Q · 05 Is this the same as a universal testing machine, a fatigue machine, a pipe tester or a hydrogen embrittlement test system?
    No, and the differences are worth stating precisely. The universal testing machine page covers a machine that pulls a specimen to break in a short test. The servo-hydraulic fatigue testing machine page covers a machine that cycles the load. The pipe hydrostatic pressure tester page covers a tester that holds a steady internal pressure on pipe. The hydrogen embrittlement test system page covers a system that holds a sustained load in hydrogen. This page is the machine that holds a metal specimen under a steady pull at a high temperature for a long time, and records its stretch or its time to break. It does not replace any of them, and it does not claim what they claim a second time.
    Q · 06 Has Neometrix built one of these?
    We would rather answer this plainly than let a page imply otherwise. Neometrix engineers creep and stress-rupture test machines to order, and no delivered creep test machine is claimed. What stands behind the offer is adjacent: the pages for a universal testing machine, a servo-hydraulic fatigue testing machine, a pipe hydrostatic pressure tester and a hydrogen embrittlement test system each describe a machine that holds a specimen under a controlled load, and each states its own status. The extensometer transducer, the thermocouples, the furnace controller, the load cell and the logger chassis are catalogue items, bought in, not invented. What Neometrix engineers is the machine around them: the frame, the lever and its levelling drive, the load train, the furnace mounting, the guards and the proof. So the honest position is that the machine is engineered to order, the neighbouring disciplines are in the building, and the first machine of this exact kind will be built around the customer's own duty rather than taken off a shelf.
    Q · 07 Which standard applies, and what can the machine not do?
    The method of a creep test is described in ISO 204 and ASTM E139, and the guides for thermocouples and for alignment are ASTM E633 and ASTM E1012. This page names them by designation. The customer states the conditions the machine is to reproduce: the metals, the pulls, the temperatures and the length of the runs. The machine makes a metal's behaviour visible and records it. It does not certify a metal, it is not a universal testing machine and not a fatigue testing machine, and it does not replace the operator's own judgement about who is near a hot furnace or a hanging weight. This page claims no certification or accreditation. No temperature, load, stress, strain, time or rate figure is printed here, and approval of a result rests with the customer and the authority they name; none is claimed here.
    Q · 08 What do you need from us to quote?
    Six things, and most of them describe your work rather than the machine. First, the metals: which ones, and the shape and size of the specimen. Second, the hold: the temperatures and pulls that matter and how long a run lasts. Third, the record: whether the strain is wanted, or only the time to break. Fourth, the stations: how many specimens run at once. Fifth, the room: what services it has, how steady its temperature is and where the logger can go. Sixth, the proof: whether a temperature survey and a test record are needed. From that we come back with a machine concept, a proving plan you can check, and a budgetary price.
    09
    Related

    The neighbouring pages, and how they differ from this one.

    Three neighbours: one pulls a specimen to break in a short test, one cycles the load, one holds a steady pressure on pipe.

    Browse all Neometrix product lines.

    Get a quotation

    Tell us the metal,
    and the hold you need.

    The projects desk replies within two working days with a machine concept, a proving plan you can check, and a budgetary quotation. Write to [email protected] or use the form.

    Enquire — creep test machine Capability sheet (PDF) +91 7777 876 876
    ISO 9001 / 14001 ENGINEERED-TO-ORDER CLASS — CREEP AND STRESS-RUPTURE TEST MACHINE DUTY · FRAME AND LEVER · FURNACE AND TEMPERATURE · STRAIN AND ALIGNMENT · CLOCK AND LOG · BUILD · PROVE — A CREEP TEST IS ONLY AS STEADY AS ITS FURNACE. ENGINEERED IN NOIDA · INDIA

    Trending Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat