200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Neometrix / Rail Test Equipment / Air Spring Test Rig / NMX-ASP-113
    NMX-ASP-113 · ENGINEERED-TO-ORDER CLASS — DUTY · FRAME AND HEIGHT · AIR AND REFERENCE · FORCE AND STIFFNESS · LOGGER AND DECISION · BUILD · PROVE

    Air Spring Test Rig. A falling pressure is not always a leak.

    A rail air spring is a rubber bellows full of compressed air that carries the weight of a coach body. Neometrix engineers the rig that proves one as a whole: the loading frame, the cylinder or lifting table that sets the height, the air circuit and the record.

    So the rig has to know that a falling pressure is not always a leak, hold the spring at the height it will work at, and read the pressure only when the air has settled.

    A two-station air spring test rig on a plain white studio background: two identical pale grey steel frames side by side, each with a short bright steel hydraulic cylinder pointing down from its top beam to a flat round platen, a smooth black rubber air spring with a steel top plate and base plate standing on a pale grey lifting table under each platen, a pale grey hydraulic power pack standing behind the right-hand station, thin black hoses running from each cylinder, a plain pale grey control cabinet at the right with a few small black switches on its sloping top, and no people
    Fig · 01 — An air spring test rig: two stations, each with a cylinder, a platen and a lifting table, sharing a power pack and a control cabinet — illustrative render.
    The leak
    is read against a referencethe air cools and the rubber settles first
    The height
    is held by the riga spring that moves changes its own pressure
    The load
    is measured, not assumeda force cell sits in the load line
    The stiffness
    belongs to the circuita reservoir makes the same bellows softer
    Status
    engineered to orderno delivery is claimed
    ISO 9001ISO 14001Test conditions set by the customer and the spring maker
    01
    Overview

    What an air spring test has to get right, and what goes wrong when it does not.

    Because a rubber bellows is not a rigid vessel, a falling pressure has more than one cause, and a test that reads too early fails good springs and can pass a spring that leaks.

    A rail air spring on a plain white studio background: a smooth black rubber bellows with two soft rounded folds standing upright, a flat round bright steel top plate with one small bright steel air fitting in its centre, a pale grey steel cylindrical base piston below the bellows, and no people
    Fig · 02 — An air spring: a rubber bellows between a top plate and a base piston, filled through one fitting — illustrative render.

    A falling pressure is not always a leak.

    What the rig is for

    It holds an air spring at its working height under its working load, fills it to its working pressure and watches the pressure. It also moves the spring through its travel and records the force, so that its stiffness is known.

    Why a spring is not a rigid vessel

    A pressure test on a steel vessel is simple, because the vessel does not change. A rubber bellows does. Its volume follows the height, and the rubber stretches and settles for a while after it is loaded.

    Why the air matters

    Filling squeezes the air, and squeezed air is warm. As it cools back to the temperature of the shop, its pressure falls, in a spring that is perfectly tight.

    Why the opposite also happens

    If the shop is warming, the pressure creeps up, and a small leak can be hidden. So the rig records the temperature, and it reads the spring against a reference vessel that has been through the same filling and is at the same temperature.

    Why the height must be held

    The pressure in a closed spring depends on its volume. If the height drifts, the pressure drifts with it. A lifting table or a cylinder holds the height against a stop, and the rig watches it.

    Why the stiffness belongs to the circuit

    A spring's stiffness comes from the air, not the rubber, and it depends on the pressure, the effective area and the volume. Joined to a reservoir, the same bellows is softer. So the rig tests the spring with the volume it will work with.

    Why two stations

    The settling takes time. A two-station rig loads one spring while the other settles, so that nobody waits and nobody reads early.

    Why an air spring test is not another test

    It is not a high-pressure leak testing machine, which holds a rigid article at a set pressure, and not a bogie test rig, which proves a whole bogie. It tests the spring itself.

    02
    The method

    Duty, frame and height, air and reference, force and stiffness, logger and decision, build and prove.

    Six steps in a fixed order. The air circuit with its reference and the blank run are the two that a quick job skips.

    1 · Duty

    The spring types, their working heights, loads and pressures, whether a reservoir is fitted, how many springs a day, the room and the services, are noted.

    2 · Frame and height

    A stiff frame carries a cylinder or a lifting table that sets the height and holds it against a stop, so that the height does not drift while the spring is read.

    3 · Air and reference

    Clean dry air is filled through a regulator and a slow valve, and a reference vessel goes through the same filling, so that the cooling of the air is seen in both.

    4 · Force and stiffness

    A force cell and a height sensor record the force against the height, with the reservoir fitted or not, so that the stiffness is known for the circuit the spring will work in.

    5 · Logger and decision

    A logger records the pressures, the temperatures, the height and the force, waits for the settle time and then applies the rule, so that a spring is judged only when the air has settled.

    6 · Build and prove

    The rig is built and leak tested, a blank is run, the force cell and the transducers are checked against references, every guard is tried, and the record goes with the rig.

    Which fault, which safeguard

    What can go wrongWhy it happensWhat the rig does about it
    A good spring fails the testthe air that was warmed by filling cooled back, and the pressure fella settle period before the reading, a temperature record, and a reference vessel at the same temperature
    A spring that leaks passesthe shop was warming, or the reading was too short, so the leak was hiddenthe same reference, a hold long enough to show a slope, and an alarm when the temperature is changing quickly
    The pressure drifts though nothing leaksthe rubber settled, or the height moved, and the volume changeda first loading that exercises the bellows, a height held by a stop, and a record of the height during the hold
    The leak is in the fixturea fitting, a hose or a plate leaked, and not the springa blank run with a plate in place of the spring before every shift, and a record of it
    The load is not the one intendedthe cylinder force was assumed and not measureda force cell in the load line, checked against a reference, and the force recorded with every test
    The stiffness cannot be comparedthe reservoir, the pressure or the speed was different from one run to the nextthe reservoir, the pressure and the rate set and recorded, so that two springs are tested the same way
    The pressure reading is wrongthe transducer drifted or was never checkedtransducers checked against a reference, and the zero checked at the start of each run
    Someone is hurt by a loaded springthe spring holds air under pressure and the cylinder holds a loada guard round each station, a relief valve on the air circuit, and a procedure that says nobody opens a charged spring

    The step people underrate is the blank run. A rig that never ran a blank cannot say how much of the leak it saw was the spring's.

    03
    Work content

    What the rig contains, element by element.

    Read it as a checklist: a rig missing a row will still fill a spring and watch it, but it will not give a reading that can be trusted and compared.

    The air side of an air spring test on a plain white studio background: a tall smooth black rubber air spring shaped like a cylinder on a flat pale grey steel base plate, a thin black hose from its top fitting to a small grey steel valve manifold with two small black transducer bodies on top and three bright steel fittings below, a long bright steel cylindrical reservoir lying on a pale grey stand and a shorter bright steel cylindrical vessel beside it, joined by thin black hoses, and no people
    Fig · 03 — The air side: the spring, a manifold with its valves and transducers, a reservoir and a reference vessel — illustrative render.
    ElementWhat it doesWhat matters
    Loading framecarries the loada stiff frame with room for the spring, the table and the cylinder, and a stop that sets the height
    Cylinder and power packpress the spring to heighta hydraulic cylinder with its power pack and a valve that holds the position, with the force read in the load line
    Lifting tablebrings the spring into placea hydraulic table or trolley that lifts the spring to the platen and lowers it again, with a lock
    Height sensorreads the heighta sensor that reads the height and a stop that holds it, so that a drift is seen at once
    Force cellreads the loada cell under the platen, checked against a reference, and read with every test
    Air supply and regulatorfill the springclean dry air through a regulator and a slow-fill valve, so that the filling is gentle and the same every time
    Pressure transducersread the pressureone on the spring and one on the reference vessel, or a differential transducer between them
    Reference vesselshares the thermal historya rigid vessel of similar volume that is filled with the spring and sits beside it, so that the cooling shows in both
    Temperature sensorsread the air and the shopsensors on the spring, the reference vessel and the room, logged with the pressure
    Reservoir connectionjoins the extra volumea port and a hose to the spring's own reservoir, or to a master reservoir, for the stiffness test
    Logger and controllerrun the sequencea sequence that fills, settles, holds, reads and decides, with the settle time and the limit set by the customer, and a log of every run
    Guards and reliefprotect peoplea guard round each station, a relief valve on the air circuit, and a vent that is safe to open
    Testing & documentationprove the rig firsta leak test, a blank run, the force cell and the transducers checked against references, every guard tried, and a record the customer can inspect

    The elements that decide the result are the reference vessel and the settle time. The first takes the cooling of the air out of the reading, and the second lets the rubber finish moving.

    Full specification — expand
    SystemA loading frame with a hydraulic cylinder or a lifting table that sets and holds the height, a force cell in the load line and a height sensor with a stop; an air circuit with a regulator, a slow-fill valve, a manifold, a reference vessel and a connection for the spring's reservoir; pressure transducers on the spring and the reference vessel and temperature sensors on the spring, the reference and the room; a logger and controller that fill, settle, hold, read and decide; a guard round each station, a relief valve and a safe vent; and a leak test, a blank run and documentation before handover
    The One IdeaA falling pressure is not always a leak.
    Why A Pressure Can Fall Without A LeakFilling squeezes the air and warms it, and the pressure falls as it cools back. A rubber bellows settles after loading and its volume follows its height. A warming shop does the opposite and can hide a small leak
    Why The Reference MattersA reference vessel that has been through the same filling shares the thermal history, so the cooling of the air shows in both and is taken out of the reading
    Why The Stiffness Belongs To The CircuitA spring's stiffness comes from the air, and it depends on the pressure, the effective area and the volume, so a reservoir makes the same bellows softer
    StandardsNo test standard is quoted here. The conditions to be reproduced are stated by the customer and the spring maker, and approval of a spring rests with the customer and the authority they name; none is claimed here. No certification or accreditation is claimed here
    ConfigurationsA leakage bench, a load and stiffness rig, and a multi-station soak bench
    Scope BoundaryThis page is the air spring test rig, which tests the spring itself. It is not a high-pressure leak testing machine, which holds a rigid article at a set pressure (see high-pressure leak testing machine), not a bogie test rig, which proves a whole bogie (see bogie test rig and turntable), not a coach and rake test rig, which proves brake equipment on a whole coach or rake (see single wagon, coach and rake test rigs) and not a spring testing machine, which tests mechanical springs (see spring testing machine). It does not certify a spring, and it does not replace the operator's own judgement
    StatusNeometrix engineers air spring test rigs to order, and no delivered air spring test rig is claimed.
    04
    Configurations

    One method, three ways to build the rig.

    The method, the blank run and the settle rule are shared. What changes is what is recorded, how many springs are on test at once and how long each stays.

    Leakage bench

    Fill, settle, hold, read

    For proving that a spring holds its air: two stations on a lifting table, so that one spring is loaded while the other settles, with a reference vessel, temperature sensors and a rule that reads only when the air has settled.

    Load and stiffness rig

    The force against the height

    For knowing what a spring does under load: a cylinder, a force cell and a height sensor that record the force against the height, with the reservoir fitted or not, at a set pressure and a set rate.

    Multi-station soak bench

    Several springs, one frame

    For springs that must stay loaded for a long time: several stations in a row under one frame and one power pack, each with its own pressure and height record, so that a slow leak is seen as a slope.

    And the part that is not equipment at all, yet decides all three: the conditions. The pressures, heights, loads, settle times and limits come from the customer's duty and the spring maker, not from the rig.

    05
    The drawings

    A reference set, drawn as real CAD sheets.

    Two sheets of one reference configuration: the arrangement of a two-station air spring test rig with three details, and its hydraulic, measurement and decision circuits with the curves that show why a falling pressure is not always a leak. They show the stations, the spring in section and the air circuit with its reference vessel. They carry tags and letters only. Every pressure, load, height and time is fixed by design for the customer's duty.

    Reference drawing sheet one, the arrangement and details of a two-station air spring test rig. An elevation shows two identical stations, each with a loading frame, a hydraulic cylinder on its top beam, a force cell and a platen over an air spring that stands on a hydraulic lifting table, with a height sensor beside the spring; a power pack with hoses to the two cylinders; a trench carrying the sensor cables to a control cabinet that holds a controller, a logger, signal inputs and a supply. Detail A shows the air spring in section, with its top plate, two folds of bellows, base piston, air fitting and the port to a reservoir. Detail B shows the air circuit: a supply, a regulator, a fill valve, a relief valve, isolating valves, the spring, a reference vessel, two pressure transducers and two temperature sensors. Detail C shows the two stations in a staggered cycle, so that one spring settles while the other is loaded or read. An item list numbers eight parts. A title block stamped reference configuration, not for construction
    Fig · 04 — Sheet 01, the arrangement: two stations, the spring in section, the air circuit with its reference vessel and the two-station cycle. Reference configuration, letters only.
    Reference drawing sheet two, the circuits and the curves of a two-station air spring test rig. A circuit shows a power pack feeding a cylinder valve and a table valve, which serve two cylinders and two lifting tables, with a guard switch that stops the pump; and a measurement chain in which the spring and reference pressures, the air temperatures, the room temperature, the force and the height feed a logger and controller that applies a settle rule and a limit and raises an alarm. Detail A is a computed plot of pressure against time for a tight spring and a leaking one: both fall at first, and only after the air has settled does the tight one go flat. Detail B is a computed plot of the pressure difference to the reference vessel, in which the cooling cancels and only the settling of the rubber and the leak remain. Detail C is a computed plot of force against height for the bellows alone and with its reservoir, the same bellows being softer with the reservoir. A title block stamped reference configuration, not for construction
    Fig · 05 — Sheet 02, the circuits and the curves: the hydraulic and measurement circuits, a tight spring against a leaking one, the reference, and the effect of a reservoir. Reference configuration, tags only.

    Every real rig is drawn for its own springs, its own pressures and its own room. These sheets are the arrangement and the order of working that a project set starts from. Approval of any drawing rests with the customer and the authority they name; none is claimed here.

    06
    Where it is used

    Wherever a coach rides on air, and the spring has to be proven before it is fitted.

    The common thread is a rubber bellows that carries a coach body for years, and a test that has to tell a tight spring from a leaking one.

    Rail workshops

    Where springs come off coaches at overhaul, and each one is tested before it goes back.

    Coach and train-set builders

    Where new springs arrive in sets and every one is proven before the bogie is assembled.

    Air spring makers

    Where a new design, or a change of rubber, has to be shown to hold its air and to have the stiffness it was drawn with.

    Suspension development groups

    Where the effect of a reservoir, a pressure or a height on the ride is measured and not assumed.

    07
    Watch

    See it in motion.

    A short walkthrough video of the air spring test rig.

    08
    FAQ

    Common questions.

    Longer answers, for readers who want the reasoning.

    Q · 01 What does an air spring test rig actually do?
    It proves that an air spring holds its air and carries its load. A lifting table or a cylinder brings the spring to its working height and holds it there under a measured load, a slow valve fills it to its working pressure, and the rig waits for the air and the rubber to settle. It then watches the pressure over a hold, against a reference vessel that went through the same filling, and applies the customer's rule. In another run it moves the spring through its travel and records the force against the height, with the reservoir fitted or not, so that the stiffness is known. A logger keeps every run. The rig does not choose the test. That comes from the customer's own duty and the spring maker, and the rig is built, proved and recorded to carry it out.
    Q · 02 Why is a falling pressure not always a leak?
    Because filling a spring squeezes the air, and squeezed air is warm. As it cools back to the temperature of the shop, its pressure falls, and nothing has leaked. A rubber bellows also settles for a while after it is loaded, so its volume changes a little, and the pressure follows it. The opposite can happen too: in a shop that is warming, the pressure creeps up and can hide a small leak. A reading taken straight after filling is therefore a reading of the air cooling, and a reading taken in a warming shop can flatter a spring that leaks. So the rig lets the spring settle, records the temperature, and reads the spring against a reference vessel that has the same thermal history.
    Q · 03 Why read the spring against a reference vessel?
    Because the reference takes the temperature out of the reading. A rigid vessel of similar volume is filled at the same time and sits beside the spring, so the air in it warms and cools in the same way. Whatever the temperature does to one, it does to the other, and the difference between the two is left with what the temperature did not cause: the rubber settling, and any real leak. Public work on pressure decay testing describes the same idea, that two volumes with mirrored thermal effects cancel each other. The reference does not replace the settle time. It shortens the wait and makes the reading easier to trust, and the blank run shows how well it works.
    Q · 04 Why must the height be held, and why two stations?
    The pressure in a closed spring depends on its volume, and its volume depends on its height. If the height drifts while the pressure is being read, the pressure drifts with it and the reading means nothing. So a stop sets the height, a sensor watches it, and the rig records it through the hold. Settling takes time, and a rig with one station would leave the operator waiting. With two stations, one spring is loaded and filled while the other is settling or being read, so nobody waits and nobody reads early. A multi-station bench goes further for long soaks, with several springs under one frame, each with its own record.
    Q · 05 Is this the same as a leak testing machine, a bogie test rig, a coach test rig or a spring testing machine?
    No, and the differences are worth stating precisely. The high-pressure leak testing machine page covers a machine that holds a rigid article at a set pressure. The bogie test rig and turntable page covers equipment that proves a whole bogie. The single wagon, coach and rake test rigs page covers rigs for brake equipment at the level of a whole coach or rake. The spring testing machine page covers a machine for mechanical springs. This page is the rig that tests an air spring itself, for its leakage and its stiffness. It does not replace any of them, and it does not claim what they claim a second time.
    Q · 06 Has Neometrix built one of these?
    We would rather answer this plainly than let a page imply otherwise. Neometrix engineers air spring test rigs to order, and no delivered air spring test rig is claimed. What stands behind the offer is adjacent: the pages for a bogie test rig, a coach and rake test rig, a spring testing machine and a high-pressure leak testing machine each describe equipment that loads a part or holds it at pressure and watches the result, and each states its own status. The pressure transducers, the force cell, the temperature sensors, the valves and the logger chassis are catalogue items, bought in, not invented. What Neometrix engineers is the rig around them: the frame, the cylinder and lifting table, the air circuit with its reference vessel, the guards and the proof. So the honest position is that the rig is engineered to order, the neighbouring disciplines are in the building, and the first rig of this exact kind will be built around the customer's own duty rather than taken off a shelf.
    Q · 07 Which standard applies, and what can the rig not do?
    No test standard is quoted on this page. Spring makers and rail authorities publish their own conditions, and the customer states the ones the rig is to reproduce: the pressures, the heights, the loads, the settle time and the limit. The rig makes a spring's behaviour visible and records it. It does not certify a spring, it is not a bogie test rig and not a spring testing machine, and it does not replace the operator's own judgement about who is near a loaded spring and when. This page claims no certification or accreditation. No pressure, load, height, stiffness, time or temperature figure is printed here, and approval of a spring rests with the customer and the authority they name; none is claimed here.
    Q · 08 What do you need from us to quote?
    Six things, and most of them describe your work rather than the rig. First, the springs: which types, their sizes and whether a reservoir is fitted. Second, the conditions: the pressures, heights and loads that matter and the limit on the pressure loss. Third, the tests: leakage, stiffness, or a long soak. Fourth, the throughput: how many springs a day, which decides the number of stations. Fifth, the room: what services it has, how steady its temperature is and how much space there is. Sixth, the record: whether a blank run and a test record are needed. From that we come back with a rig concept, a proving plan you can check, and a budgetary price.
    09
    Related

    The neighbouring pages, and how they differ from this one.

    Three neighbours: one holds a rigid article at pressure, one proves a whole bogie, one proves a whole coach or rake.

    Browse all Neometrix product lines.

    Get a quotation

    Tell us the spring,
    and the limit on the loss.

    The projects desk replies within two working days with a rig concept, a proving plan you can check, and a budgetary quotation. Write to [email protected] or use the form.

    Enquire — air spring test rig Capability sheet (PDF) +91 7777 876 876
    ISO 9001 / 14001 ENGINEERED-TO-ORDER CLASS — AIR SPRING TEST RIG DUTY · FRAME AND HEIGHT · AIR AND REFERENCE · FORCE AND STIFFNESS · LOGGER AND DECISION · BUILD · PROVE — A FALLING PRESSURE IS NOT ALWAYS A LEAK. ENGINEERED IN NOIDA · INDIA

    Trending Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat
    move to top arrow