High Pressure Leak Testing Machine

About

The High Pressure Leak Testing Machine is a fully automated pneumatic test system designed for precise leak detection in industrial components ranging from 1.2 to 20 liters in volume. Operating at pressures up to 250 Bar, it features an air-driven booster, dome-loaded pressure regulation, and a 10” touchscreen HMI with PLC-based automation. The system supports multiple test modes—including static leak, pressure hold, stepwise pressure, and real-time pressure vs. time profiling—making it ideal for quality control and endurance testing in automotive, aerospace, railways, and defense sectors. Built with premium components and advanced safety features, it ensures reliable performance, high repeatability, and operator safety in demanding production environments.
No Image

Image Gallery

Technical Details

Feature Specification
Test Pressure Range 20 to 250 Bar (adjustable)
Component Volume Capacity 1.2 Liters (min) to 20 Liters (max)
Test Medium Clean Dry Compressed Air / Nitrogen
Pressure Generation Air-driven gas booster system (Haskel equivalent)
Dome-Loaded Regulator Amplification Ratio: 44:1, Max Output: 5000 psi, Connection: 1/4" NPT
Air Receiver Tanks 6 Liters @ 350 Bar (High Pressure), 6 Liters @ 16 Bar (Low Pressure)
Analog Pressure Gauges 0–16 Bar and 0–400 Kg/cm², Glycerine-filled, SS316L, 100 mm dial (WIKA)
Digital Pressure Transmitters 0–400 Bar, Output: 4–20 mA, Accuracy: 0.25% FS, SS316 Body & Wetted Parts
Pilot Pressure Switch Set at 300 Bar, 1/4" NPT
Control Panel Touchscreen HMI (10”) + Schneider PLC
Solenoid Valves Festo 3/2 & 2/2, Normally Closed/Open, 1/4” & 1/2” BSP, 220–230 VAC
Actuated Ball Valves 1/4” OD, Pneumatically actuated, Ham-Let make, NO/NC configuration
Safety Relief Valve Range: 275–344 Bar, 1/4” tube OD, Spring-loaded fail-safe design
I/O Monitoring Live diagnostic screen for digital inputs/outputs, valve states, and alarms
Safety Features Emergency stop, pressure vent logic, tower light with buzzer (R/Y/G indicators)
Emergency Venting Pneumatic pressure exhaust path with interlocked control
Mounting & Safety Cage Table-mounted enclosure with interlock; optional grouted floor cage for larger DUTs
Compressed Air Requirement 6–8 Bar filtered dry air
Electrical Requirement (Control) 230 V AC (Solenoid valves), 24 V DC (Control logic & indicators)
 • Automotive Industry: Brake and clutch actuators, EGR valves, air suspensions
 • Aerospace & Defense: Pneumatic control valves, actuator canisters, launch interface subsystems
 • Railways: Door actuators, brake distributor valves, compressed air tanks
 • Medical & Gas Systems: Oxygen/nitrogen valve assemblies, pressure reducers
 • Heavy Industry & Automation: Pneumatic cylinders, regulators, control valves

Key Features

  • Leak Testing (Static Pressure Decay Method)
  • Pressure vs. Time Profiling
  • Direct Outlet Pressure Mode
  • Stepwise Pressure Ramp (Step Pressure Mode)

Download Gallery

×

Enquire Now

and we will get back to you.

  • United States+1
  • United Kingdom+44
  • Afghanistan (‫افغانستان‬‎)+93
  • Albania (Shqipëri)+355
  • Algeria (‫الجزائر‬‎)+213
  • American Samoa+1
  • Andorra+376
  • Angola+244
  • Anguilla+1
  • Antigua and Barbuda+1
  • Argentina+54
  • Armenia (Հայաստան)+374
  • Aruba+297
  • Australia+61
  • Austria (Österreich)+43
  • Azerbaijan (Azərbaycan)+994
  • Bahamas+1
  • Bahrain (‫البحرين‬‎)+973
  • Bangladesh (বাংলাদেশ)+880
  • Barbados+1
  • Belarus (Беларусь)+375
  • Belgium (België)+32
  • Belize+501
  • Benin (Bénin)+229
  • Bermuda+1
  • Bhutan (འབྲུག)+975
  • Bolivia+591
  • Bosnia and Herzegovina (Босна и Херцеговина)+387
  • Botswana+267
  • Brazil (Brasil)+55
  • British Indian Ocean Territory+246
  • British Virgin Islands+1
  • Brunei+673
  • Bulgaria (България)+359
  • Burkina Faso+226
  • Burundi (Uburundi)+257
  • Cambodia (កម្ពុជា)+855
  • Cameroon (Cameroun)+237
  • Canada+1
  • Cape Verde (Kabu Verdi)+238
  • Caribbean Netherlands+599
  • Cayman Islands+1
  • Central African Republic (République centrafricaine)+236
  • Chad (Tchad)+235
  • Chile+56
  • China (中国)+86
  • Christmas Island+61
  • Cocos (Keeling) Islands+61
  • Colombia+57
  • Comoros (‫جزر القمر‬‎)+269
  • Congo (DRC) (Jamhuri ya Kidemokrasia ya Kongo)+243
  • Congo (Republic) (Congo-Brazzaville)+242
  • Cook Islands+682
  • Costa Rica+506
  • Côte d’Ivoire+225
  • Croatia (Hrvatska)+385
  • Cuba+53
  • Curaçao+599
  • Cyprus (Κύπρος)+357
  • Czech Republic (Česká republika)+420
  • Denmark (Danmark)+45
  • Djibouti+253
  • Dominica+1
  • Dominican Republic (República Dominicana)+1
  • Ecuador+593
  • Egypt (‫مصر‬‎)+20
  • El Salvador+503
  • Equatorial Guinea (Guinea Ecuatorial)+240
  • Eritrea+291
  • Estonia (Eesti)+372
  • Ethiopia+251
  • Falkland Islands (Islas Malvinas)+500
  • Faroe Islands (Føroyar)+298
  • Fiji+679
  • Finland (Suomi)+358
  • France+33
  • French Guiana (Guyane française)+594
  • French Polynesia (Polynésie française)+689
  • Gabon+241
  • Gambia+220
  • Georgia (საქართველო)+995
  • Germany (Deutschland)+49
  • Ghana (Gaana)+233
  • Gibraltar+350
  • Greece (Ελλάδα)+30
  • Greenland (Kalaallit Nunaat)+299
  • Grenada+1
  • Guadeloupe+590
  • Guam+1
  • Guatemala+502
  • Guernsey+44
  • Guinea (Guinée)+224
  • Guinea-Bissau (Guiné Bissau)+245
  • Guyana+592
  • Haiti+509
  • Honduras+504
  • Hong Kong (香港)+852
  • Hungary (Magyarország)+36
  • Iceland (Ísland)+354
  • India (भारत)+91
  • Indonesia+62
  • Iran (‫ایران‬‎)+98
  • Iraq (‫العراق‬‎)+964
  • Ireland+353
  • Isle of Man+44
  • Israel (‫ישראל‬‎)+972
  • Italy (Italia)+39
  • Jamaica+1
  • Japan (日本)+81
  • Jersey+44
  • Jordan (‫الأردن‬‎)+962
  • Kazakhstan (Казахстан)+7
  • Kenya+254
  • Kiribati+686
  • Kosovo+383
  • Kuwait (‫الكويت‬‎)+965
  • Kyrgyzstan (Кыргызстан)+996
  • Laos (ລາວ)+856
  • Latvia (Latvija)+371
  • Lebanon (‫لبنان‬‎)+961
  • Lesotho+266
  • Liberia+231
  • Libya (‫ليبيا‬‎)+218
  • Liechtenstein+423
  • Lithuania (Lietuva)+370
  • Luxembourg+352
  • Macau (澳門)+853
  • Macedonia (FYROM) (Македонија)+389
  • Madagascar (Madagasikara)+261
  • Malawi+265
  • Malaysia+60
  • Maldives+960
  • Mali+223
  • Malta+356
  • Marshall Islands+692
  • Martinique+596
  • Mauritania (‫موريتانيا‬‎)+222
  • Mauritius (Moris)+230
  • Mayotte+262
  • Mexico (México)+52
  • Micronesia+691
  • Moldova (Republica Moldova)+373
  • Monaco+377
  • Mongolia (Монгол)+976
  • Montenegro (Crna Gora)+382
  • Montserrat+1
  • Morocco (‫المغرب‬‎)+212
  • Mozambique (Moçambique)+258
  • Myanmar (Burma) (မြန်မာ)+95
  • Namibia (Namibië)+264
  • Nauru+674
  • Nepal (नेपाल)+977
  • Netherlands (Nederland)+31
  • New Caledonia (Nouvelle-Calédonie)+687
  • New Zealand+64
  • Nicaragua+505
  • Niger (Nijar)+227
  • Nigeria+234
  • Niue+683
  • Norfolk Island+672
  • North Korea (조선 민주주의 인민 공화국)+850
  • Northern Mariana Islands+1
  • Norway (Norge)+47
  • Oman (‫عُمان‬‎)+968
  • Pakistan (‫پاکستان‬‎)+92
  • Palau+680
  • Palestine (‫فلسطين‬‎)+970
  • Panama (Panamá)+507
  • Papua New Guinea+675
  • Paraguay+595
  • Peru (Perú)+51
  • Philippines+63
  • Poland (Polska)+48
  • Portugal+351
  • Puerto Rico+1
  • Qatar (‫قطر‬‎)+974
  • Réunion (La Réunion)+262
  • Romania (România)+40
  • Russia (Россия)+7
  • Rwanda+250
  • Saint Barthélemy+590
  • Saint Helena+290
  • Saint Kitts and Nevis+1
  • Saint Lucia+1
  • Saint Martin (Saint-Martin (partie française))+590
  • Saint Pierre and Miquelon (Saint-Pierre-et-Miquelon)+508
  • Saint Vincent and the Grenadines+1
  • Samoa+685
  • San Marino+378
  • São Tomé and Príncipe (São Tomé e Príncipe)+239
  • Saudi Arabia (‫المملكة العربية السعودية‬‎)+966
  • Senegal (Sénégal)+221
  • Serbia (Србија)+381
  • Seychelles+248
  • Sierra Leone+232
  • Singapore+65
  • Sint Maarten+1
  • Slovakia (Slovensko)+421
  • Slovenia (Slovenija)+386
  • Solomon Islands+677
  • Somalia (Soomaaliya)+252
  • South Africa+27
  • South Korea (대한민국)+82
  • South Sudan (‫جنوب السودان‬‎)+211
  • Spain (España)+34
  • Sri Lanka (ශ්‍රී ලංකාව)+94
  • Sudan (‫السودان‬‎)+249
  • Suriname+597
  • Svalbard and Jan Mayen+47
  • Swaziland+268
  • Sweden (Sverige)+46
  • Switzerland (Schweiz)+41
  • Syria (‫سوريا‬‎)+963
  • Taiwan (台灣)+886
  • Tajikistan+992
  • Tanzania+255
  • Thailand (ไทย)+66
  • Timor-Leste+670
  • Togo+228
  • Tokelau+690
  • Tonga+676
  • Trinidad and Tobago+1
  • Tunisia (‫تونس‬‎)+216
  • Turkey (Türkiye)+90
  • Turkmenistan+993
  • Turks and Caicos Islands+1
  • Tuvalu+688
  • U.S. Virgin Islands+1
  • Uganda+256
  • Ukraine (Україна)+380
  • United Arab Emirates (‫الإمارات العربية المتحدة‬‎)+971
  • United Kingdom+44
  • United States+1
  • Uruguay+598
  • Uzbekistan (Oʻzbekiston)+998
  • Vanuatu+678
  • Vatican City (Città del Vaticano)+39
  • Venezuela+58
  • Vietnam (Việt Nam)+84
  • Wallis and Futuna (Wallis-et-Futuna)+681
  • Western Sahara (‫الصحراء الغربية‬‎)+212
  • Yemen (‫اليمن‬‎)+967
  • Zambia+260
  • Zimbabwe+263
  • Åland Islands+358

Details

The High Pressure Leak Testing Machine is a precision-engineered, fully automated pneumatic test platform designed for high-accuracy, high-reliability leak detection in industrial components exposed to elevated internal pressures. Equipped with a sophisticated control ecosystem—featuring a PLC-based logic system and an intuitive 10” HMI touchscreen—the machine offers programmable test sequences, digital pressure monitoring, automated safety control, and data-driven process validation.

Designed to accommodate components ranging from compact solenoid valves to large pneumatic actuators, the machine enables high-pressure testing across a broad operational envelope (1.2 liters to 20 liters in volume). With flexible mounting and connection options, it is suitable for in-line quality inspection, batch testing, and destructive or endurance testing in sectors such as automotive, aerospace, railways, defense, and industrial automation.

The system’s rugged mechanical structure, high-grade instrumentation (WIKA, Haskel, Festo, Norgren), and built-in safety mechanisms make it ideal for high-frequency industrial use, ensuring compliance with international test protocols while maximizing operator safety and operational uptime.

Functional Testing Capabilities
The machine supports multiple distinct testing protocols, each optimized for specific applicationscenarios:
1. Leak Testing (Static Pressure Decay Method)
 • Operator defines the target test pressure, hold time, and maximum allowable pressure drop.
 • The system fills the DUT (Device Under Test) to the setpoint using the air booster.
 • The pressure is held and monitored for decay using precision transmitters.
 • Any drop beyond the set threshold flags a leak, with automatic pass/fail feedback.

2. Pressure vs. Time Profiling
 • Enables programmable pressure rise, holding durations, and decay measurements.
 • Real-time graphical plotting of the pressure profile helps identify material behavior under load.
 • Used for endurance, fatigue, and burst-pressure limit evaluation.

3. Direct Outlet Pressure Mode
 • Allows real-time control of pressure directly to the outlet port for tuning, calibration, or single-point validation.
 • Especially useful for testing components with dynamic internal valves, chambers, or flow paths.

4. Stepwise Pressure Ramp (Step Pressure Mode)
 • Multi-stage pressure increases in programmable increments.
 • Each step is held for a defined duration to simulate cyclic loading or operational pressure staircases.
 • Useful for parts undergoing fatigue testing or with pressure-dependent deformation characteristics.
Each mode is governed by a safety-verified logic sequence and offers manual override, digital diagnostics, and emergency handling capabilities.

Technical Specifications
 
Feature Specification
Test Pressure Range 20 to 250 Bar (adjustable)
Component Volume Capacity 1.2 Liters (min) to 20 Liters (max)
Test Medium Clean Dry Compressed Air / Nitrogen
Pressure Generation Air-driven gas booster system (Haskel equivalent)
Dome-Loaded Regulator Amplification Ratio: 44:1, Max Output: 5000 psi, Connection: 1/4" NPT
Air Receiver Tanks 6 Liters @ 350 Bar (High Pressure), 6 Liters @ 16 Bar (Low Pressure)
Analog Pressure Gauges 0–16 Bar and 0–400 Kg/cm², Glycerine-filled, SS316L, 100 mm dial (WIKA)
Digital Pressure Transmitters 0–400 Bar, Output: 4–20 mA, Accuracy: 0.25% FS, SS316 Body & Wetted Parts
Pilot Pressure Switch Set at 300 Bar, 1/4" NPT
Control Panel Touchscreen HMI (10”) + Schneider PLC
Solenoid Valves Festo 3/2 & 2/2, Normally Closed/Open, 1/4” & 1/2” BSP, 220–230 VAC
Actuated Ball Valves 1/4” OD, Pneumatically actuated, Ham-Let make, NO/NC configuration
Safety Relief Valve Range: 275–344 Bar, 1/4” tube OD, Spring-loaded fail-safe design
I/O Monitoring Live diagnostic screen for digital inputs/outputs, valve states, and alarms
Safety Features Emergency stop, pressure vent logic, tower light with buzzer (R/Y/G indicators)
Emergency Venting Pneumatic pressure exhaust path with interlocked control
Mounting & Safety Cage Table-mounted enclosure with interlock; optional grouted floor cage for larger DUTs
Compressed Air Requirement 6–8 Bar filtered dry air
Electrical Requirement (Control) 230 V AC (Solenoid valves), 24 V DC (Control logic & indicators)
Automation & Software HMI Interface: - Responsive 10-inch touchscreen - Multi-language support (expandable) - Test configuration, monitoring, historical data access PLC Control Logic: - Reliable, deterministic control for sequencing valves and monitoring sensors - Safeguarded interlocks prevent unsafe operation - Expandable for future I/O, data logging, and remote access integration Data Visualization: - Real-time pressure vs. time plots - Clear test status indicators - On-screen pressure decay representation Data Handling (optional upgrade): - Exportable test logs - USB/SD/Cloud connectivity options - Calibration record storage and automated alerts Service & Maintenance Schedule • Before Each Use: Visual inspection, check oil level and tightness of fittings • Weekly: Leak detection (spray or drop method), clean exterior and HMI screen • Monthly: Test pressure sensors for drift, verify system zeroing post-depressurization • Quarterly: Full booster inspection, re-torque adapters, check wiring, inspect dome regulator • Semi-Annual: Replace clogged filters, recalibrate gauges and transmitters, PRV testing • Annual: Overhaul of all pressure circuit components, update firmware if applicable • Every 5 Years: Major maintenance on booster, PRV, dome regulator, and system-wide leak test Application Domains • Automotive Industry : Brake and clutch actuators, EGR valves, air suspensions • Aerospace & Defense : Pneumatic control valves, actuator canisters, launch interface subsystems • Railways : Door actuators, brake distributor valves, compressed air tanks • Medical & Gas Systems : Oxygen/nitrogen valve assemblies, pressure reducers • Heavy Industry & Automation : Pneumatic cylinders, regulators, control valves Advantages at a Glance • High Precision: ±0.25% full-scale measurement with SS316L components • Total Automation: One-touch test cycles with no manual intervention • Industry-Grade Build: Built using globally trusted brands—WIKA, Norgren, Festo, Haskel, Ham-Let • Modular Platform: Future integration of burst testing, hydrostatic, or climate conditioning possible • Operator Safety: Interlocked enclosures, emergency shutdown, auto-venting logic • Application Flexibility: Compatible with a wide range of geometries and test setups • Documentation & Traceability: Can be integrated with barcode/QR-based test log systems

Trending Products