200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Neometrix/Fuel Injection Test Equipment/Electronic Unit Pump Test Stand
    ELECTRONICALLY CONTROLLED PUMPS

    Electronic Unit Pump Test Stand. Test both together.

    An electronic unit pump serves one cylinder. A cam moves its plunger, and a solenoid valve decides when pressure builds and how long it lasts.

    So a bench that only turns the pump tells you half the story. The stand has to drive it and command it at the same time.

    Illustrative render of an EUI and EUP test bench for electronic unit pumps and unit injectors, with touch screen, windowed test chamber and wheeled stand
    Fig · 01 — An electronic unit pump test stand — illustrative render
    01
    Description

    How an EUI or EUP test bench proves a unit.

    The pump is run on the bench the way the engine runs it, and judged against the data for its part number.

    Cam drive

    A cam box matched to the pump moves the plunger at the speeds the test plan calls for, with its own lubrication and a guard over the moving parts.

    Solenoid driver

    Driver electronics pull the valve in and hold it with the current profile the pump expects, for the start angle and duration being tested.

    Delivery measurement

    The fuel delivered per stroke is measured at several operating points, from starting and idle conditions up to full load.

    Response of the valve

    The solenoid current trace shows when the valve actually closed, so a slow or sticking valve is separated from a worn plunger.

    Electrical and leak checks

    Coil resistance and insulation are checked, and the pump is watched for external leakage while it runs.

    Oil and records

    Calibration fluid is filtered and held at a steady temperature, and each result is stored against the pump's serial number.

    02
    What we need from you

    Four things before we quote.

    ItemWhy it matters
    Pump part numbersthey fix the cam profile, mounting and test points
    Test data you holdlimits come from the maker of the pump, not from the stand
    Solenoid detailsthey set the driver current and voltage
    Workshop serviceselectric supply, air and space decide the build

    Pumps driven mechanically, with no solenoid, are covered by the multipurpose fuel injection pump test rig. Neometrix offers electronic unit pump test stands to order, and no delivered unit is claimed here.

    03
    Unit injectors too

    EUI testing on the same method.

    Electronic unit pump (EUP)

    A separate cam-driven pump for each cylinder, with its own solenoid valve, feeding the injector through a short high pressure pipe.

    Electronic unit injector (EUI)

    Pump, solenoid valve and nozzle in one body in the cylinder head, worked by the engine camshaft.

    What changes on the bench

    An injector mounting and spray chamber take the place of the pump mounting, so that nozzle behaviour is seen along with delivery and solenoid response.

    What stays the same

    Cam drive, command of the solenoid, measured delivery per stroke, controlled calibration fluid and a stored result against the part number.

    04
    Where it is used

    Unit pump and unit injector testing for heavy diesel engines.

    Marine engine workshops

    Fuel pumps and injectors from propulsion and generator engines are overhauled and proved before refitting.

    Locomotive and heavy engine shops

    Large diesel engines need injection equipment set evenly from cylinder to cylinder.

    Mining, earthmoving and power

    Dumpers, excavators and diesel generator sets return to work sooner when pumps and injectors are tested in house.

    Diesel injection service centres

    Service centres and defence maintenance workshops record each pump and injector against its test data.

    05
    FAQ

    EUI and EUP testing: common questions.

    Q · 01What is the difference between EUI and EUP?
    An electronic unit injector (EUI) combines pump, solenoid valve and nozzle in one body. An electronic unit pump (EUP) is a separate cam-driven pump with a solenoid valve that feeds an injector through a short pipe.
    Q · 02Why can an ordinary pump bench not test them fully?
    Because the solenoid valve decides when and how long fuel is delivered. The bench has to drive the unit from a cam and command the valve at the same time.
    Q · 03What does the solenoid current trace show?
    The moment the valve closes. A late or irregular closure points to the valve, while low delivery with a normal closure points to the plunger and barrel.
    Q · 04What information is needed for a quotation?
    The unit pump or injector part numbers, the test data you hold, the solenoid details and the services available in your workshop.
    Q · 05Can mechanical unit pumps be tested?
    Pumps with no solenoid are covered by the multipurpose fuel injection pump test rig.
    Get a quotation

    Tell us the unit pumps
    you need to prove.

    We reply with a stand concept, a test plan outline and a budgetary quotation. Write to [email protected] or [email protected], or use the form.

    Enquire about this stand → +91 7777 876 876
    Fuel injection test equipmentNeometrix Defence Limited · Noida · India

    Trending Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat
    move to top arrow