200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Neometrix / Compressed Air & Gas Systems / Helium Recovery and Purification System / NMX-HRV-124
    NMX-HRV-124 · ENGINEERED-TO-ORDER CLASS — SOURCES · CAPTURE · BUFFER · COMPRESS AND DRY · PURIFY AND CHECK · RETURN

    Helium Recovery System. Catch it before the air does.

    Helium that has done its job is often let go into the room, and from there it cannot practically be got back. Neometrix engineers the helium recovery and purification system that catches it: a closed collection line, a gas bag, a recovery compressor, filters, a dryer, a purifier and an analyser.

    So the system has to know that air mixed in at the start has to be paid for at the end, the bag takes the burst so that the compressor need not, and gas is only reusable once it has been checked.

    A helium recovery system on a plain white studio background: a large soft pale grey gas bag in an open steel frame beside a skid carrying an enclosed compressor, two narrow bright steel adsorber vessels and one wider vessel, bright steel tubing and a rack of plain pale grey gas cylinders, with no people
    Fig · 01 — A helium recovery system: a gas bag, a compressor, adsorber and purifier vessels and a rack of storage cylinders — illustrative render.
    The source
    is where it is lostan open vent lets it go for good
    The bag
    takes the burstso the compressor need not
    The air
    is paid for laterevery bit mixed in must come out
    The dryer
    comes before the coldmoisture would block the purifier
    Status
    engineered to orderno delivery is claimed
    ISO 9001ISO 14001The purity and the amount come from the process that uses the gas
    01
    Overview

    What a recovery system has to get right, and where the gas is really lost.

    A system that catches helium late, or catches it mixed with air, saves less than it appears to. Most of the result is decided before the gas reaches the compressor.

    A helium gas bag on a plain white studio background: a large soft matte pale grey fabric bag held inside an open welded steel frame, with a black hose joined to a fitting at its foot and a slim steel rod reaching from the frame to rest on top of the bag, and no people
    Fig · 02 — A gas bag in its frame, with a hose at its foot and a rod on top that follows how full it is — illustrative render.

    Catch it before the air does.

    What the system is for

    It collects the helium a process lets go, holds it, cleans it and returns it for use again. The gas passes from the vent to a closed line, a bag, a compressor, a dryer and a purifier.

    Why recover at all

    Helium comes mostly from natural gas and cannot be made. Once it has left into the open air it is, for any practical purpose, gone, and its price and supply are not steady.

    Why at the source

    The best place to catch the gas is where it leaves the process. A closed coupling keeps it nearly as clean as it came. An open hood over a vent draws in the room with it.

    Why a bag

    A test or a purge lets gas go in short bursts. A flexible bag takes each burst at close to room pressure, so the compressor can be sized for the average flow.

    Why the bag must not be drawn flat

    If the compressor keeps pulling on an empty bag, the line falls below room pressure and pulls air in through its joints. A low-level switch stops the compressor first.

    Why compress and filter

    The compressor packs the gas into cylinders. A lubricated one needs coalescers and an activated carbon filter after it, because oil spoils both the purifier and the gas.

    Why dry before purifying

    Moisture freezes in a cold purifier and blocks it. The gas is dried first, and its dew point is watched.

    Why purify and check

    Air that came in with the gas is removed by a cold adsorber or another purifying stage. An analyser at the outlet says whether the gas is good enough, and poor gas is kept apart.

    Why it is not a charging station

    A charging station fills cylinders and a leak detector finds leaks. This system saves the gas that such work lets go.

    02
    The method

    Sources, capture, buffer, compress, purify and return.

    Six steps in a fixed order. Keeping air out at the capture and keeping a balance of the gas are the two that a quick job skips.

    1 · Sources

    Every point that lets helium go is listed, with how much, how often and how clean. The system never invents a source.

    2 · Capture

    Closed couplings and non-return valves take the gas into one header, and a monitor at the inlet watches for air, so that air is kept out rather than removed later.

    3 · Buffer

    The gas fills a flexible bag sized for the biggest burst, with level sensing and a relief, so that the compressor runs on a steady draw.

    4 · Compress and dry

    The compressor draws from the bag into cylinders through filters and a dryer, and stops before the bag is flat, so that oil and water come out before the cold stage.

    5 · Purify and check

    The purifier takes out the air that came with the gas, and an analyser checks the outlet, so that only gas that passes goes to the clean store.

    6 · Return and account

    Clean gas goes back to the process, make-up covers what was lost, and meters keep a balance, so that a loss is seen and not assumed.

    Which fault, which safeguard

    What can go wrongWhy it happensWhat the system does about it
    Air gets into the bagan open vent, a loose joint, or a compressor drawing on an empty bagclosed couplings, a monitor at the inlet, a low-level stop and a divert valve
    The bag overfillsgas arrives faster than the compressor takes ita bag sized for the burst, a high-level start and a relief piped outdoors
    Oil reaches the gaslubricant is carried over from the compressoran oil-free compressor, or coalescers and an activated carbon filter
    The purifier blocksmoisture freezes in the cold stagea dryer ahead of it and a dew point monitor
    Air breaks through the purifierthe adsorber has taken all it can holdan analyser at the outlet, a change-over and regeneration
    The gas is not good enough to reusetoo much air was mixed in at the capturethe inlet is watched and poor gas is stored apart
    A room fills with heliuma leak, or a relief venting indoorsreliefs piped outdoors, ventilation and an oxygen monitor in the room
    The savings are not therelosses that nobody measuredmeters on the return and the make-up, and a balance kept over time

    The step people underrate is the capture. A purifier can only remove the air that was let in, and removing it costs helium, adsorbent and time that a closed coupling would have saved.

    03
    Work content

    What the system contains, element by element.

    Read it as a checklist: a system missing a row will still collect some gas, but it will not give back gas a process can trust.

    The purifying section of a helium recovery system on a plain white studio background: two narrow upright bright steel adsorber vessels and one wider vessel on a pale grey base frame, joined by bright steel tubing with plain black-handled valves, with no people
    Fig · 03 — A purifying section: two adsorber vessels, so that one can work while the other is regenerated, and a wider vessel beside them — illustrative render.
    ElementWhat it doesWhat matters
    Collection headergathers the ventsclosed couplings and non-return valves, so that gas flows one way and air does not flow back
    Inlet monitorwatches for airan oxygen or purity monitor that sends poor gas to a divert valve rather than into the bag
    Gas bagtakes the burstsa flexible bag in a frame, sized for the biggest burst, held at close to room pressure
    Level sensingstarts and stops the drawa high level and a low level, so that the bag neither overfills nor is drawn flat
    Reliefprotects the baga relief piped outdoors, so that a full bag cannot be strained
    Recovery compressorpacks the gassuited to helium, which finds small gaps, with its heat carried away and its seals checked
    Filterstake out oil and dustcoalescers and an activated carbon filter after the compressor, with their drains
    Dryertakes out wateran adsorbent dryer that can be regenerated, with a dew point monitor after it
    Purifiertakes out aira cold adsorber, or another purifying stage chosen from the purity wanted, with its regeneration
    Analyserproves the gasa purity analyser at the outlet that sends poor gas back instead of into the clean store
    Storage and returnholds clean gashigh pressure cylinders with their own approvals, a regulator on the return and a make-up connection
    Controls and safetyrun it unattendeda sequence with alarms, an oxygen monitor in the room and a record of gas recovered and made up

    The elements that decide the result are the couplings at the source and the gas bag. The first keep the air out, and the second lets the compressor work steadily.

    Full specification — expand
    SystemA collection header with closed couplings and non-return valves; an inlet monitor and a divert valve; a flexible gas bag in a frame with level sensing and a relief; a recovery compressor; coalescers, an activated carbon filter and a dryer; a purifier with regeneration; a purity analyser; high pressure storage, a return regulator and a make-up connection; controls, alarms and records; and a proving run and documentation before handover
    The One IdeaCatch it before the air does.
    Why At The SourceAir drawn into the collection has to be removed later. A purifier holds only so much, so more air means more regeneration and more helium vented with it
    Why A BagGas arrives in bursts. A flexible bag takes each burst near room pressure, so the compressor can be sized for the average flow
    StandardsNo standard is quoted here. The purity and the amount come from the process that uses the gas and the authority the customer names, and approval of pressure vessels and cylinders rests with them; none is claimed here. No certification or accreditation is claimed here
    ConfigurationsCollect and store, recover and reuse, and recover and purify
    Scope BoundaryThis page is the helium recovery and purification system, which saves the helium a process lets go. It is not a helium leak detector, which finds leaks (see helium leak detection system), not a charging station, which refills and tests cylinders (see helium charging station) and not a boosting and decanting machine, which raises and delivers stored helium (see helium boosting and decanting machine). It is not a liquefier: it returns gas, not liquid. It does not choose the purity the process needs
    StatusNeometrix engineers helium recovery and purification systems to order, and no delivered helium recovery and purification system is claimed.
    04
    Configurations

    One method, three ways to build the system.

    The collection, the bag and the compressor are shared. What changes is how clean the gas has to be before it is used again.

    Collect and store

    For gas to be cleaned later

    Couplings, a bag, a compressor, filters, a dryer and cylinders, so that nothing is vented while the gas waits to be purified here or elsewhere.

    Recover and reuse

    For a process that accepts the collected purity

    The same line with an analyser, returning filtered and dry gas to the same job, with poor gas kept apart.

    Recover and purify

    For a process that needs clean gas again

    The line above with a purifier and its regeneration, and a second check at the outlet, returning gas at the purity the process asks for.

    And the part that is not equipment at all, yet decides all three: the purity the process needs. It sets whether filtering and drying are enough, or whether the air must be taken out as well.

    05
    The drawings

    A reference set, drawn as real CAD sheets.

    Two sheets of one reference configuration: the arrangement of a helium recovery and purification system with three details, and the order of work with the curves that show why to catch it before the air does. They show the flow from the test points to the store, the gas bag, the capture and the cold adsorber. They carry tags and letters only. Every size, flow and purity is fixed by design for the customer's process.

    Reference drawing sheet one, the arrangement and details of a helium recovery and purification system. A flow arrangement runs from three test points with non-return valves into one header, past an inlet monitor and a divert valve into a gas bag held in a frame with a level sensor and a relief piped outdoors, then through a recovery compressor, a filter, a dryer of two vessels, a purifier in a cold bath and an analyser into storage cylinders, with a return regulator and a make-up connection to the process. Detail A shows the gas bag full and low with the level sensor arm. Detail B compares an open hood over a vent, which draws in air, with a closed coupling and a non-return valve. Detail C is a section of the cold adsorber: a bed in a vessel held in a bath. An item list numbers twelve parts. A title block stamped reference configuration, not for construction
    Fig · 04 — Sheet 01, the arrangement: the flow from the test points to the store, the gas bag, capture at the source and the cold adsorber. Reference configuration, tags only.
    Reference drawing sheet two, the sequence and the curves of a helium recovery and purification system. A sequence of boxes shows the work: list the sources, capture the gas through closed couplings, buffer it in the bag, compress and dry it, purify and check it, and return it and keep a balance. Detail A is a computed plot of the content of the bag against time: bursts of gas raise it sharply and the compressor draws it down between a start level and a stop level, with the bag sized above the biggest burst. Detail B is a computed plot of the gas an adsorber can process in one run against the share of air in the feed: it falls steeply. Detail C is a computed plot of the share of the helium returned against the share of air: it falls as the air rises. A title block stamped reference configuration, not for construction
    Fig · 05 — Sheet 02, the sequence and the curves: the order of work, the bag and the burst, the run that air shortens and the helium that air costs. Reference configuration, tags only.

    Every real system is drawn for its own sources, its own amounts and its own purity. These sheets are the arrangement and the order of working that a project set starts from. Approval of any drawing rests with the customer and the authority they name; none is claimed here.

    06
    Where it is used

    Wherever helium is used once, and then let go.

    The common thread is a process that lets helium out at a point which could be closed and collected.

    Leak testing shops

    Where parts are tested with helium, and the chamber or the part is pumped out after each test. That outlet is where the gas is usually vented.

    Pressure and proof testing

    Where valves, vessels and components are pressurised with helium, and the gas is let down at the end of every test.

    Cryogenic laboratories

    Where liquid helium boils off from vessels and instruments, and the gas can be warmed, collected and cleaned.

    Process cooling and purging

    Where helium cools or purges a process, and its outlet can be closed so that the gas comes back with little else in it.

    07
    Watch

    See it in motion.

    A short walkthrough video of the helium recovery system.

    08
    FAQ

    Common questions.

    Longer answers, for readers who want the reasoning.

    Q · 01 What does a helium recovery and purification system actually do?
    It collects the helium that a process lets go, holds it, cleans it and returns it. Closed couplings take the gas from the vent points into one header, and a monitor watches for air. A flexible bag takes the bursts at close to room pressure. A compressor draws from the bag into cylinders through filters and a dryer. A purifier takes out the air that came with the gas, and an analyser checks what comes out. Clean gas goes back to the process, make-up covers the losses, and meters keep a balance. The system does not choose the purity the process needs. The process does, and the system is built, proved and recorded to meet it.
    Q · 02 Why catch it before the air does?
    Because helium that has mixed with air is not lost yet, but it costs more to save. Every bit of air drawn into the collection has to be taken out again by the purifier. A purifier holds only so much, so more air means that it is full sooner, that it must be regenerated more often, and that more helium is vented with each regeneration. A closed coupling at the source keeps the gas close to the purity it left with. An open hood over a vent does not: it draws in the room with the gas. So the first effort in a recovery system is best spent on the connections, before the compressor and the purifier are chosen.
    Q · 03 Why a gas bag instead of pumping straight into cylinders?
    Because the gas does not arrive at a steady rate. A leak test, a purge or a let-down releases a burst and then nothing. A compressor big enough to swallow each burst would stand idle most of the time, and between bursts it would pull the line below room pressure and draw air in. A flexible bag takes the burst at close to room pressure and gives it to a smaller compressor at a steady draw. The bag is sized for the biggest burst, and the compressor for the average flow. Level sensing starts the compressor as the bag fills and stops it before the bag is flat.
    Q · 04 Why must the gas be filtered and dried before it is purified?
    Because the purifier works cold, and water freezes there. Moisture that reaches a cold adsorber forms ice, which blocks the passages and takes up room that is needed for holding air. Oil from a lubricated compressor coats the adsorbent and stays with the gas. So the gas passes coalescers, an activated carbon filter and a dryer first, and its dew point is watched. The dryer is regenerated in its turn. A system that leaves this out may work for a short while and then show a rising pressure drop and a falling purity, and the cause is found upstream of the purifier rather than inside it.
    Q · 05 Is this the same as a charging station, a boosting and decanting machine or a leak detector?
    No, and the differences are worth stating precisely. The helium leak detection system page covers equipment that finds leaks with helium. The helium charging station page covers a skid that refills and tests cylinders and moves the gas left in them between cylinders. The helium boosting and decanting machine page covers raising the pressure of stored helium and delivering it. This page is the system that collects the helium a process lets go, cleans it and returns it. It does not replace any of them, and it does not claim what they claim a second time.
    Q · 06 Has Neometrix built one of these?
    We would rather answer this plainly than let a page imply otherwise. Neometrix engineers helium recovery and purification systems to order, and no delivered helium recovery and purification system is claimed. What stands behind the offer is adjacent: the pages for the helium charging station, the helium boosting and decanting machine and the helium leak detection system each describe equipment that handles helium, and each states its own status. The compressor, the analysers and the adsorbent are catalogue items, bought in, not invented. What Neometrix engineers is the system around them: the collection, the bag and its frame, the filtering and drying train, the purifier layout, the controls and the proof. So the honest position is that the system is engineered to order, and the first one of this exact kind will be built around the customer's own process rather than taken off a shelf.
    Q · 07 Which standard applies, and what can the system not do?
    No standard is quoted on this page. The customer states the process, the purity it needs and the authority that governs its pressure equipment, and that sets the rest. The system saves gas that can be collected. It cannot recover gas that stays inside a part or that has already left into the open air, and it returns gas rather than liquid, so it is not a liquefier. This page claims no certification or accreditation. No size, flow, pressure, purity, temperature or time figure is printed here, and approval of pressure vessels and cylinders rests with the authority the customer names; none is claimed here.
    Q · 08 What do you need from us to quote?
    Six things, and most of them describe your process rather than the system. First, the sources: every point that lets helium go. Second, the amount: how much each releases, and how often. Third, the purity: what the process needs back. Fourth, the contaminants: the oil, water or other gases the process adds. Fifth, the site: where the bag and the compressor can stand, and how the room is ventilated. Sixth, the record: how the gas recovered and made up is to be logged. From that we come back with a system concept, a proving plan you can check, and a budgetary price.
    09
    Related

    The neighbouring pages, and how they differ from this one.

    Three neighbours: one finds leaks, one fills cylinders, one raises and delivers.

    Browse all Neometrix product lines.

    Get a quotation

    Tell us where it goes,
    and the purity you need back.

    The projects desk replies within two working days with a system concept, a proving plan you can check, and a budgetary quotation. Write to [email protected] or use the form.

    Enquire — helium recovery Capability sheet (PDF) +91 7777 876 876
    ISO 9001 / 14001 ENGINEERED-TO-ORDER CLASS — HELIUM RECOVERY AND PURIFICATION SYSTEM SOURCES · CAPTURE · BUFFER · COMPRESS · PURIFY · RETURN — CATCH IT BEFORE THE AIR DOES. ENGINEERED IN NOIDA · INDIA

    Trending Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat
    move to top arrow