200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Neometrix / Vacuum & Gas Systems / High-Vacuum Pumping Station / NMX-HVP-89
    NMX-HVP-89 · ENGINEERED-TO-ORDER CLASS — SURVEY · SIZE THE LINE · CHOOSE THE PUMPS · INTERLOCK · BUILD · PROVE

    High-Vacuum Pumping Station. The pipe sets the speed.

    A high-vacuum pumping station takes a chamber from atmosphere down to a high vacuum and holds it there. It is a roughing pump, a turbomolecular pump on a backing pump, a gate valve, gauges and a controller, on one frame. Neometrix engineers it as a system around the customer's chamber: the pipe to it, the order of the pumps, the valves, the interlock and the proof.

    So the station has to reach the chamber through a short, wide pipe, start its pumps in the right order, and close the chamber off when anything goes wrong.

    A trolley-mounted high-vacuum pumping station on a plain white studio background: a rigid pale grey steel frame on four castor wheels carrying an upright stainless turbomolecular pump with a round flange on its top, a pale grey backing pump on the lower shelf joined to it by a flexible stainless hose, a blank pale grey controller box on the frame and a stainless handle, and no people
    Fig · 01 — A trolley-mounted pumping station: a turbomolecular pump with its flange ready for the chamber, a backing pump on the shelf below, and a controller, on one frame — illustrative render.
    The result
    a chamber at high vacuumheld there, and read truly
    The line
    short, wide and straightwith the pump close to the chamber
    The pumps
    roughed first, then the turboon a backing pump that keeps its outlet low
    The safety
    closed off on any faultgate valve, gauges and a slow dry vent
    Status
    engineered to orderno delivered installation claimed
    ISO 9001ISO 14001ISO 3529-1 reference vocabulary
    01
    Overview

    Why the pump is the easy part, and the pipe and the order decide the result.

    Because a large pump on a long, thin line sees the chamber only through that line, and the line is the slower of the two.

    A pumped vacuum chamber on a plain white studio background: a squat upright brushed stainless cylinder with a domed top on three short legs, a short wide straight stainless pipe dropping from its underside into a stainless valve housing and a stainless turbomolecular pump in one vertical line, a slim stainless gauge tube branching from the chamber side to a plain small cylindrical gauge head, clamp rings on every joint, and no people
    Fig · 02 — The pump close under the chamber: a short, wide, straight pipe to a gate valve and a turbomolecular pump, so that the pipe takes little of the speed — illustrative render.

    The pipe sets the speed.

    What the station is for

    It pumps down a chamber that has to run in a high vacuum: a coating or thin-film process, a surface-science experiment, an instrument or a detector, a part that is being outgassed or leak-checked. It takes the air out, keeps it out, and tells the operator the truth about the pressure.

    Why the pipe sets the speed

    The speed at the chamber is the speed of the pump in series with the conductance of the pipe between them, so it is always below both. A long, thin pipe throttles a large pump, and a short, wide one lets a smaller pump do the job. So the pump goes close to the chamber and the line is straight and wide.

    Why the pumps run in order

    A turbomolecular pump cannot start against atmosphere. A roughing pump takes the chamber down first, the turbomolecular pump is started, and a backing pump holds its outlet low. One backing pump often does both jobs, through a roughing valve and a foreline valve.

    Why the backing pump is chosen with care

    An oil-sealed pump can send oil vapour back toward the chamber. A dry pump cannot. So a dry backing pump is chosen where the chamber has to stay clean, and a trap is fitted where oil is used.

    Why the gauges are chosen for the range

    A thermal gauge reads the rough range, and an ionisation or cold-cathode gauge reads the high range. A combination gauge joins them. A gauge reads differently for different gases, so a reading is a reading and not a proof.

    Why the station is interlocked

    A power failure, a stopping pump or a rising pressure must close the chamber off and not spoil it. So the gate valve closes by itself, the gauges permit each step, and nothing opens until the pressure says it may.

    Why the vent is slow and dry

    Letting room air into a chamber puts water on its walls, and water is what slows the next pump-down. So the vent uses dry gas through a restrictor, and waits for the turbomolecular pump to slow as its maker states.

    Why the proof is a curve and a test

    A leak keeps the pressure rising at a steady rate. A surface giving off gas rises more slowly, and slows further. So the station is proved by the pump-down curve and by a rate-of-rise test, and the record goes with it.

    02
    The method

    Survey, size the line, choose the pumps, interlock, build and prove.

    Six steps in a fixed order. The line and the proof are the two that a quick job skips.

    1 · Survey

    The chamber, its surfaces, the gases and the process are noted, with the pressure the work needs and how soon it has to be reached.

    2 · Size the line

    The pipe from the chamber to the pump is drawn first, as short, wide and straight as the layout allows, with the fewest bends and valves in it, because it sets the speed.

    3 · Choose the pumps

    A turbomolecular pump, a backing pump and the valves are chosen for the gas load and for the cleanliness the chamber needs, dry or oil-sealed, with a trap where oil is used.

    4 · Interlock

    A controller starts the pumps in order, opens the gate valve only when the pressure permits, closes it on any fault, and vents slowly and dry.

    5 · Build

    The frame, the pipework and the flanges are built from clean parts, with the right seal for each joint, and the line is leak-checked before the pumps are joined to it.

    6 · Prove

    The pump-down is recorded, a rate-of-rise test is run, the interlock is exercised, power failure included, and the record is handed over with the station.

    Which pump, which job

    PumpHow it worksWhat to watch
    Oil-sealed rotary vane pumptraps gas between vanes and an oil film and pushes it outoil vapour can drift back toward the chamber, so it needs a trap or a chamber that can take it
    Dry scroll pumpmoves gas along between two scrolls, with no oilclean, but its tips wear, and it does not reach quite as far as an oil-sealed pump
    Diaphragm pumpflexes a membrane to move the gas, with no oildry and quiet, but it reaches only a modest vacuum, so it suits a small turbomolecular pump
    Turbomolecular pump (this page)spinning blades knock the gas toward the outletit needs a backing pump, and it must not be vented or knocked while it spins fast
    Ion or cryogenic pumpholds the gas on a surface instead of moving it outit fills up, so it is used for ultra-high vacuum and needs regenerating or replacing

    The step people underrate is the line. Narrow it a little and the pumping falls a great deal, because the conductance goes with the cube of the width.

    03
    Work content

    What the station contains, element by element.

    Read it as a checklist: a station missing a row will pump, but it will not reach the vacuum, or keep the chamber safe when something fails.

    A complete pumped high-vacuum system on a plain white studio background: a plain stainless cylindrical chamber on a pale grey steel frame, a short wide stainless pipe from its underside to a gate valve and a turbomolecular pump, a flexible stainless hose from the pump along the floor to a pale grey dry backing pump in a plain housing, and a blank pale grey controller box on a slim post, and no people
    Fig · 03 — The whole system: the chamber, the short wide pipe, the gate valve and the turbomolecular pump, the foreline to the backing pump, and the controller — illustrative render.
    ElementWhat it doesWhat matters
    Turbomolecular pumptakes the chamber from a rough vacuum to a high vacuumchosen for the gases and for the speed the line allows, started only after roughing, and not vented while it spins fast
    Backing pumpkeeps the outlet of the turbomolecular pump low, and does the roughingdry where the chamber has to stay clean, or oil-sealed with a trap
    Valvesrough the chamber, back the pump and shut the chamber offthe gate valve closes by itself on a fault, and each valve and seal is chosen for the vacuum it holds
    Pipework and flangescarry the gas from the chamber to the pumpshort, wide and straight, smooth inside, with clamped or bolted flanges and the right seal for each joint
    Gaugesread the pressurea thermal gauge for the rough range and an ionisation or cold-cathode gauge for the high range, placed where they read the chamber and not the pump
    Vent valve and restrictorlet the chamber back to atmospheredry gas, slowly, and not until the turbomolecular pump has slowed
    Bakeoutdrives water and gas off the wallsfor ultra-high vacuum: heaters and jackets, and a controller that holds the temperature
    Frame or trolleycarries the partsrigid, with the vibration of the pumps kept from the chamber and the gauges, and a clear route for hoses and cables
    Controller and interlockrun the station and keep it safestarts the pumps in order, permits each step from the gauges, and closes the chamber off on a fault or a power loss
    Cooling and supplieskeep the pumps within their limitscooling where the pump needs it, and clean power with a safe stop
    Procedure and recordfix the start, the stop, the vent and the proofthe same for every station, with the pump-down on record
    Testing & documentationprove the station firstthe line leak-checked, the pump-down recorded, a rate-of-rise test, the interlock and a power failure exercised, and a record the customer can inspect

    The elements that decide the result are the line and the order of the pumps, and the one that decides whether the chamber stays safe is the interlock. The first two bring the chamber to its vacuum, and the third closes it off when something fails.

    Full specification — expand
    SystemA turbomolecular pump on a backing pump, dry or oil-sealed; a roughing line and a foreline valve; a gate valve to the chamber; a thermal gauge and a high-vacuum gauge, or a combination gauge; a vent valve with a restrictor and dry gas; a rigid frame with clamped or bolted flanges; bakeout heating where the vacuum needs it; a controller with an interlock; a written procedure; a pump-down record; and testing and documentation before handover
    The One IdeaThe pipe sets the speed.
    Why The Pipe Sets The SpeedThe speed at the chamber is the speed of the pump in series with the conductance of the pipe between them, so it is always below both; the conductance of a long tube rises with the cube of its diameter and falls with its length, so a short, wide, straight line is worth more than a bigger pump on a long, thin one
    Why The Pumps Run In OrderA turbomolecular pump cannot start against atmosphere: a roughing pump takes the chamber down first, the turbomolecular pump is started, and a backing pump holds its outlet low; one backing pump often does both jobs through a roughing valve and a foreline valve
    Why The Station Is InterlockedA power failure, a stopping pump or a rising pressure must close the chamber off and not spoil it, so the gate valve closes by itself, the gauges permit each step, and the vent is slow and dry
    StandardsISO 3529-1 covers the vocabulary of vacuum technology and ISO 2861 covers clamped quick-release couplings, the clamped joint used on small vacuum flanges. This page prints none of their dimensions or limits, and no edition year: those come from the standard the customer names. Approval of a station rests with the customer and the authority they name; none is claimed here
    ConfigurationsA trolley-mounted station, a rack-mounted station for a fixed chamber, and a station for ultra-high vacuum
    Scope BoundaryThis page is the high-vacuum pumping station, which takes a chamber to a high vacuum and holds it there. It is not a thermal vacuum chamber, which is the chamber with its thermal shrouds (see thermal vacuum chamber), not a helium leak detection system, which finds a leak with a tracer gas (see helium leak detection system) and not a hypobaric altitude chamber, which holds a low pressure for people (see hypobaric altitude chamber). It does not cure a leak or a chamber that gives off gas: it shows them. It does not make a flammable or reactive gas safe to pump: that needs its own design. No certification or accreditation is claimed here
    StatusNeometrix has quoted against successive high-vacuum pumping station requirements, and no delivered high-vacuum pumping station is claimed.
    04
    Configurations

    One method, three ways to build the station.

    The method, the line, the order of the pumps and the proof are shared. What changes is where the chamber stands and how clean the vacuum has to be.

    Trolley-mounted station

    A turbomolecular pump and a backing pump on wheels, for one chamber or a few

    For a laboratory with more than one chamber: the station rolls to the chamber, joins it by one wide flange and a gate valve, and pumps it down.

    Rack-mounted station for a fixed chamber

    Built around the chamber, with the pump close under it

    For a chamber that stays where it is: the pump on a short wide pipe, a gate valve, the gauges, the vent and the controller on one frame, interlocked with the process.

    Station for ultra-high vacuum

    For work that needs the cleanest vacuum, with bakeout and a pump that holds it

    For ultra-high vacuum: metal-sealed flanges, bakeout heating and its controller, and an ion or cryogenic pump to hold the vacuum once it has been reached.

    And the part that is not equipment at all, yet decides all three: the survey and the test plan. They fix the chamber, the line to it, the gases, the order of the pumps and the checks at handover. They are written from the customer's own chamber and process, not from the pump.

    05
    The drawings

    A reference set, drawn as real CAD sheets.

    Two sheets of one reference configuration: the process and instrument schematic of a high-vacuum pumping station, and its general arrangement with three details. They show the chamber, the short wide line, the pumps, the gauges, the vent and the interlock, the pipe that sets the speed, the pumping order and the clamped joint. They carry tags and letters only. Every pressure, speed, flow and size is fixed by design for the customer's chamber and process.

    Reference drawing sheet one, the process and instrument schematic of a high-vacuum pumping station. A pumping station controller sits above a vacuum chamber with two gauges on its top and a vent on its side, the vent taking dry gas through a valve and a restrictor. A short, wide, straight line leads from the chamber through a gate valve to a turbomolecular pump, which discharges through a foreline valve to a foreline with a pressure gauge, an oil trap and a backing pump that exhausts to a safe place. A roughing line with a roughing valve runs from the chamber to the foreline. Every valve is drawn closed without power. A legend, a table of holds and releases, ten notes and a title block stamped reference configuration, not for construction
    Fig · 04 — Sheet 01, the process and instrument schematic: the chamber, the short wide line, the turbomolecular and backing pumps, the gauges, the vent and what holds or releases the sequence. Reference configuration, tags only.
    Reference drawing sheet two, the general arrangement and details of a high-vacuum pumping station. An elevation of a rack-mounted station shows a chamber on a frame, a short wide line dropping through a gate valve to a turbomolecular pump, a foreline hose to a backing pump on the floor, a controller cabinet, a gauge and a vent valve, with dimension letters for the length and diameter of the line. A plan shows a trolley-mounted station with its turbomolecular pump, backing pump, controller and castors, with dimension letters for its width and depth. An item list numbers ten parts. Detail A compares a short, wide, straight line with a long, thin, bent one. Detail B is a table of valve states for roughing, starting, running and venting. Detail C is a section through a clamped joint with a centring ring and a seal. A title block stamped reference configuration, not for construction
    Fig · 05 — Sheet 02, the general arrangement and details: the station in elevation and plan, the pipe that sets the speed, the pumping order and the clamped joint. Reference configuration, letters only.

    Every real station is drawn for its own chamber, gases and site. These sheets are the arrangement and the order of control that a project set starts from. Approval of any drawing rests with the customer and the authority they name; none is claimed here.

    06
    Where it is used

    Wherever a chamber has to run in a high vacuum, and the pressure has to be right.

    The common thread is a chamber that has to be clean, a vacuum that has to be reached on time, and a reading that has to be trusted.

    Coating and thin-film development

    Where a chamber has to be clean and at high vacuum before a layer is made.

    Surface-science and materials laboratories

    Where the chamber is the experiment, and the pressure has to be known and steady.

    Instrument and detector builders

    Where an assembly has to run, or be tested, in vacuum.

    Test and conditioning rooms

    Where parts are outgassed, leak-checked or run in vacuum before they are used.

    07
    Watch

    See it in motion.

    A short walkthrough video of the high.

    08
    FAQ

    Common questions.

    Longer answers, for readers who want the reasoning.

    Q · 01 What does a high-vacuum pumping station actually do?
    It takes a chamber from atmosphere to a high vacuum and holds it there. A roughing pump takes most of the air out first. A turbomolecular pump then takes the chamber the rest of the way, on a backing pump that keeps its outlet low. A gate valve joins it to the chamber, gauges read the pressure, a vent lets the air back in, and a controller runs the sequence and closes the chamber off on a fault. It does not decide what pressure a process needs or what gas it may use: those come from the customer's own work, and the station holds to them.
    Q · 02 Why does the pipe to the chamber matter so much?
    Because the speed at the chamber is the speed of the pump in series with the conductance of the pipe between them, and a series pair is always below both. At high vacuum the conductance of a long tube rises with the cube of its diameter and falls with its length, so a narrow or long line throttles even a very large pump. A short, wide, straight line does the opposite: it lets a smaller pump do what a larger one cannot. Every bend, valve and reducer in the line adds resistance. So the survey draws the line first, and the pump goes where the line is shortest.
    Q · 03 Why a backing pump, and why not start the turbomolecular pump at once?
    A turbomolecular pump works only when the gas is thin enough for its blades to push single molecules, so it cannot start against atmosphere. A roughing pump takes the chamber down first. The turbomolecular pump is then started, and a backing pump holds its outlet at a pressure it can work against. One backing pump often does both jobs, through a roughing valve and a foreline valve. The choice of backing pump matters too. An oil-sealed pump reaches a little further, but it can send oil vapour back toward the chamber. A dry scroll or diaphragm pump cannot, so it is chosen where the chamber has to stay clean.
    Q · 04 Why the gate valve, the gauges and the interlock?
    Because the things that go wrong are quick and the harm is slow to undo. A power failure, a pump that stops or a pressure that rises can let air or oil into a clean chamber, or put a spinning rotor at risk. So the gate valve closes by itself, and the gauges permit each step: the foreline valve opens only when the roughing has done its work, the turbomolecular pump starts only when the pressure allows, and the gate valve opens only when the pump is up to speed. The vent is slow and dry, because room air puts water on the walls and water is what slows the next pump-down. The interlock is what makes a mistake cost a restart and not a ruined chamber.
    Q · 05 Is this the same as the thermal vacuum chamber, the helium leak detection system or the hypobaric altitude chamber?
    No, and the differences are worth stating precisely. The thermal vacuum chamber page covers the chamber with its thermal shrouds. The helium leak detection system page covers finding a leak with a tracer gas. The hypobaric altitude chamber page covers a chamber that holds a low pressure for people. This page is the high-vacuum pumping station, which takes a chamber to a high vacuum and holds it there. It does not replace any of them, and it does not claim what they claim a second time.
    Q · 06 Has Neometrix built one of these?
    We would rather answer this plainly than let a page imply otherwise. Neometrix has quoted against successive high-vacuum pumping station requirements, and no delivered high-vacuum pumping station is claimed. What stands behind the offer is adjacent: Neometrix engineers a thermal vacuum chamber (see the thermal vacuum chamber page), a helium leak detection system (see the helium leak detection system page) and a hypobaric altitude chamber (see the hypobaric altitude chamber page). The pumps, valves, gauges, flanges and controller parts are catalogue items, bought in, not invented. What Neometrix engineers is the system around them: the survey, the line to the chamber, the choice and order of the pumps, the valves, the frame, the interlock, the procedure and the record. So the honest position is that the station is engineered to order, the neighbouring disciplines are in the building, and the first station of this exact kind will be built around the customer's own chamber rather than taken off a shelf.
    Q · 07 Which standard applies, and what can the station not do?
    ISO 3529-1 covers the vocabulary of vacuum technology and ISO 2861 covers clamped quick-release couplings, the clamped joint used on small vacuum flanges. This page prints none of their dimensions or limits, and no edition year: those come from the standard the customer names. The station takes a chamber to a high vacuum and holds it there. It does not cure a leak or a chamber that gives off gas, it only shows them, it does not make a flammable or reactive gas safe to pump, which needs its own design, and it does not replace the customer's own vacuum and safety checks: this page claims no certification or accreditation. No pressure, speed, flow, size or quantity figure is printed here, and approval for use rests with the customer and the authority they name; none is claimed here.
    Q · 08 What do you need from us to quote?
    Six things, and most of them describe your chamber rather than the station. First, the chamber: its size, its surfaces and its ports, and where it stands. Second, the gases: what the process puts into the chamber, and whether any of it is flammable, reactive or corrosive. Third, the vacuum: the pressure the work needs and how soon it has to be reached. Fourth, the process: what happens if the vacuum is lost, and whether it can be stopped. Fifth, the supplies: power, cooling and a dry gas for the vent. Sixth, the record: what you want kept for each pump-down. From that we come back with a station concept, a written test plan you can check, and a budgetary price.
    09
    Related

    The neighbouring pages, and how they differ from this one.

    Three neighbours: one is the chamber, one finds a leak, one holds a low pressure for people.

    Browse all Neometrix product lines.

    Get a quotation

    Tell us the chamber,
    and the vacuum it needs.

    The projects desk replies within two working days with a station concept, a written test plan you can check, and a budgetary quotation. Write to [email protected] or use the form.

    Enquire — high-vacuum pumping station Capability sheet (PDF) +91 7777 876 876
    ISO 9001 / 14001 ENGINEERED-TO-ORDER CLASS — HIGH-VACUUM PUMPING STATION SURVEY · SIZE THE LINE · CHOOSE THE PUMPS · INTERLOCK · BUILD · PROVE — THE PIPE SETS THE SPEED ENGINEERED IN NOIDA · INDIA

    Trending Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat
    move to top arrow