200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Neometrix / Laboratory Heating Equipment / Laboratory Oven / NMX-LBO-104
    NMX-LBO-104 · ENGINEERED-TO-ORDER CLASS — DUTY · CHAMBER AND SHELVES · HEAT AND AIR OR VACUUM · CONTROL AND CUT-OUT · BUILD · PROVE

    Laboratory Oven. The sensor is not the sample.

    A laboratory oven holds a space at a set temperature, so that material can be dried, aged or cured. A hot-air oven moves heated air over the load. A vacuum oven takes the air away, so that a solvent leaves at a low temperature. Neometrix engineers both as a system: the chamber, the heating, the control, the protection and the proof.

    So the oven has to know that the sensor is not the sample, carry the heat to where the load is, and cut out on its own when the controller fails.

    A hot-air laboratory oven on a plain white studio background: a stainless-steel cabinet on four small feet with its door open to the left, a bright stainless chamber with three wire shelves and a perforated back panel, a pale grey side panel with two black knobs and a rocker switch, and no people
    Fig · 01 — A hot-air laboratory oven with its door open: a stainless chamber with three wire shelves, and a control panel at the side — illustrative render.
    The sensor
    reads one point, not the loadthe display shows where the sensor sits
    The map
    shows the whole chambermeasured at many points, with the oven loaded
    The heat
    carried by air, or by the shelfa vacuum oven has no air to carry it
    The cut-out
    separate from the controllerit acts when the controller cannot
    Status
    engineered to orderno delivery is claimed
    ISO 9001ISO 14001ASTM E145 reference for hot-air ovensIEC 61010-2-010 reference for heating equipment safety
    01
    Overview

    What a laboratory oven has to get right, and what goes wrong when it does not.

    Because the number on the display is the temperature of one point, and the material is somewhere else.

    A vacuum oven set on a plain white studio background: a stainless-steel cubic oven with a round glass window in its door and a chrome latch, a pale grey control panel above the door with two black knobs and a switch, a black hose to an upright stainless cold trap, a second hose to a small black vacuum pump, and no people
    Fig · 02 — A vacuum oven: a round glass door, a cold trap and a vacuum pump joined by plain hoses — illustrative render.

    The sensor is not the sample.

    What the oven is for

    It holds a space at a set temperature, so that material can be dried, aged or cured. A hot-air oven does it with moving air, and a vacuum oven does it with the air taken away.

    Why the sensor is not the sample

    The controller reads one sensor at one point. The sample sits somewhere else, and the air at that place is not exactly the air at the sensor. So the display shows the temperature of the sensor, and the sample is near it, and not at it.

    Why the chamber is mapped

    A map measures the temperature at many points in the chamber, with the oven loaded. It shows how far the corners are from the sensor, and it is the only way to know where a sample should be put.

    How a hot-air oven carries the heat

    Heaters warm the air, and a fan moves it over the shelves, so that the load is warmed all round. Without a fan the air moves only by itself, and the spread of temperature is larger.

    Why a vacuum oven dries at a low temperature

    Lowering the pressure lowers the boiling point of a solvent or of water, so that it leaves the material at a lower temperature. That suits material that heat would harm.

    Why a vacuum oven heats through the shelf

    With the air taken away there is nothing to carry heat by convection. The heat reaches the sample through the shelf, so contact with the shelf matters, and the sample lags behind it.

    Why a cold trap stands before the pump

    The vapour that leaves the sample would condense in the pump and spoil it. A cold trap between the oven and the pump collects the vapour first.

    Why the cut-out is separate

    A controller that fails can leave the heater on. A separate over-temperature cut-out has its own sensor, and it cuts the heater power on its own.

    Why an oven is not for every solvent

    An oven that is not made for flammable vapour must not be used to dry anything that gives it off. The duty states what will be dried, and the oven is built for that.

    02
    The method

    Duty, chamber and shelves, heat and air or vacuum, control and cut-out, build and prove.

    Six steps in a fixed order. The map and the cut-out are the two that a quick job skips.

    1 · Duty

    What is dried, aged or cured, in what form, at what temperature range, and whether the material gives off a solvent or a vapour, are noted.

    2 · Chamber and shelves

    The chamber, the insulation, the door and the shelves are matched to the load. A vacuum chamber is built to carry the pressure of the air outside.

    3 · Heat and air, or vacuum

    For a hot-air oven, the heaters, the fan and the air path with a vent. For a vacuum oven, heated shelves, a pump and a cold trap.

    4 · Control and cut-out

    A controller and a sensor hold the set point, and a separate cut-out with its own sensor acts when the controller cannot.

    5 · Build

    The chamber, the heaters, the air or vacuum path and the controls are built and fitted, and the door seal and the sensors are checked.

    6 · Prove

    A temperature map, a recovery check, a vacuum hold test and a cut-out test are run, and the record goes with the oven.

    Which fault, which safeguard

    What can go wrongWhy it happensWhat the oven does about it
    The sample is not at the set pointthe sensor reads one point, and the sample is elsewherea map of the chamber, a sensor placed where it is useful, and a record of how far the corners differ
    The corners are warmer or coolerthe air does not move evenlya fan and baffles, and shelves that do not block the air
    The oven overshootsthe controller is badly tuned, or the load is smalla tuned controller, and a separate over-temperature cut-out
    The oven is slow to recoverthe door was opened, and the heater is too weaka heater sized for recovery, checked in the proof
    A vacuum oven dries slowlyheat arrives only through the shelf, and the contact is poorheated shelves, flat trays and good contact with the shelf
    Vapour reaches the pumpthere is no cold trap, or the trap is fulla cold trap between the oven and the pump, and a way to empty it
    The vacuum leaksthe seal is worn, or the door is misaligneda seal and a door checked at the build, and a vacuum hold test
    Flammable vapour builds upthe oven was used for a solvent it was not made fora duty that states what is dried, and an oven built for it

    The step people underrate is the map. An oven looks the same whether its corners are close to the set point or far from it.

    03
    Work content

    What the oven contains, element by element.

    Read it as a checklist: an oven missing a row will heat a sample, but it will not tell you where the sample is.

    The open chamber of a vacuum oven on a plain white studio background: a pale grey cabinet with its door swung open to show a thick black seal and a round glass window, a bright stainless chamber with three shelves each carrying a plain shallow stainless tray, a round port in the back wall, and no people
    Fig · 03 — The chamber of a vacuum oven with its door open: three shelves with a plain tray on each, a round port in the back wall and the thick seal of the door — illustrative render.
    ElementWhat it doesWhat matters
    Chamber and insulationhold the heat ina stainless chamber with insulation around it, and for a vacuum oven a chamber that carries the pressure of the air outside
    Door and sealclose the chambera door that closes evenly on its seal, so that heat or vacuum does not leak, with a glass window on a vacuum oven
    Heatersmake the heatheaters placed so that the chamber warms evenly, and sized so that the oven recovers after the door is opened
    Fan and air pathcarry the heat in a hot-air ovena fan and baffles that move the air over every shelf, and a vent that lets moisture out
    Shelveshold the loadwire shelves for a hot-air oven that do not block the air, and flat heated shelves for a vacuum oven that touch the tray
    Controller and sensorhold the set pointa controller tuned to the chamber, and a sensor placed where a map shows it is useful
    Over-temperature cut-outacts when the controller cannota cut-out with its own sensor, in the heater supply, that does not depend on the controller
    Vacuum pumptakes the air awaya pump suited to the vapour it will meet, joined to the chamber by plain hoses
    Cold trapcollects the vapour before the pumpa trap between the oven and the pump that can be emptied, so that vapour does not spoil the pump
    Bleed valvereturns the chamber to the aira valve that lets air or an inert gas in slowly, so that the door can be opened
    Testing & documentationprove the oven firsta temperature map with the oven loaded, a recovery check, a vacuum hold test, a test of the cut-out, and a record the customer can inspect

    The elements that decide the result are the sensor and the cut-out. The first says where the heat is, and the second acts when the first cannot.

    Full specification — expand
    SystemAn insulated chamber with a sealed door and shelves; heaters; for a hot-air oven a fan and an air path with a vent; for a vacuum oven heated shelves, a vacuum-tight chamber, a vacuum pump and a cold trap; a controller and a sensor; a separate over-temperature cut-out with its own sensor; and a temperature map, a recovery check, a vacuum hold test and a cut-out test, with documentation, before handover
    The One IdeaThe sensor is not the sample.
    Why The Sensor Is Not The SampleThe controller reads one sensor at one point and the material sits somewhere else, so the display shows the temperature of the sensor; a map measures the temperature at many points with the oven loaded and shows where a sample may be put
    Why A Vacuum Oven Heats Through The ShelfWith the air taken away there is nothing to carry heat by convection, so heat reaches the sample through the shelf, contact with the shelf matters and the sample lags behind it; the lowered pressure lowers the boiling point, and a cold trap before the pump collects the vapour
    StandardsASTM E145 covers gravity-convection and forced-ventilation ovens, and IEC 61010-2-010 covers the safety of laboratory equipment for the heating of materials. This page prints none of their requirements, and no edition year. Approval of an oven rests with the customer and the authority they name; none is claimed here
    ConfigurationsA hot-air oven, a vacuum oven, and a special oven
    Scope BoundaryThis page is the laboratory oven, which dries, ages or cures material at a set temperature. It is not an environmental chamber, which holds temperature and humidity for a test (see climatic and environmental test chambers), not a hot-air generator, which heats a stream of air for a process (see hot air generator) and not a vacuum pumping station, which is the pump station for a vacuum process (see high vacuum pumping station). It does not decide what is dried, and it does not replace the operator's own judgement. No certification or accreditation is claimed here
    StatusNeometrix has quoted against successive laboratory oven and vacuum oven requirements, and no delivered laboratory oven or vacuum oven is claimed.
    04
    Configurations

    One method, three ways to build the oven.

    The method, the map and the cut-out are shared. What changes is how the heat reaches the load, and what the load gives off.

    Hot-air oven

    A chamber, heaters and a fan, with a vent for the moisture

    For drying, ageing and curing in air: heaters, a fan and baffles that move the air over every shelf, and a controller tuned to the chamber.

    Vacuum oven

    Heated shelves, a vacuum pump and a cold trap

    For material that heat or air would harm, or that holds a solvent: a vacuum-tight chamber, heated shelves, a pump, a cold trap and a bleed valve.

    Special oven

    A size, a shelf layout or an atmosphere that is not standard

    For a load that does not fit a standard oven: a larger chamber, a trolley that rolls in, or an inert gas, chosen with the customer, with the same map and the same cut-out.

    And the part that is not equipment at all, yet decides all three: what is put in the oven. It is taken from the customer's own work, not from the oven.

    05
    The drawings

    A reference set, drawn as real CAD sheets.

    Two sheets of one reference configuration: the arrangement of a laboratory oven with three details, and its control, protection and curve. They show the cabinet and the chamber, the map of a shelf, the vacuum oven, the controller and the separate cut-out, and the sensor against the sample. They carry tags and letters only. Every temperature, pressure, volume and power is fixed by design for the customer's samples.

    Reference drawing sheet one, the arrangement and details of a laboratory oven. A front elevation of a hot-air oven shows the cabinet, the door with its handle, the control panel with two knobs and a switch, the vent and the feet, with the width and the height marked by letters. A side section shows the insulated wall, hatched, the chamber, three shelves with a tray on one, the heater on the floor, the fan and the air path drawn as a loop, and the control sensor and the sensor of the cut-out. Detail A shows one shelf in plan with the control sensor and five measuring points, Detail B a vacuum oven in section with two heated shelves, a bleed valve, a cold trap and a pump, and Detail C how the heat arrives, carried by the air in a hot-air oven and only through the shelf in a vacuum oven. An item list numbers ten parts. A title block stamped reference configuration, not for construction
    Fig · 04 — Sheet 01, the arrangement: the oven in elevation and section, the map of one shelf, the vacuum oven and how the heat arrives. Reference configuration, letters only.
    Reference drawing sheet two, the control, the protection and the curve of a laboratory oven. A block diagram shows the supply feeding a solid-state relay through an over-temperature cut-out, the controller reading the control sensor and the set point and switching the relay, and the heater inside a dashed chamber; the cut-out has its own sensor and its own line. A vacuum path shows the vacuum chamber with two hatched shelves and a bleed valve, an isolating valve, a cold trap and a pump. Detail A is a computed curve: the sensor rises to the set point first, the sample follows more slowly with a gap marked between them, and when the door is opened the sensor dips at once and the sample more slowly. A table of what each step does, and a title block stamped reference configuration, not for construction
    Fig · 05 — Sheet 02, the control and the curve: the controller and the separate cut-out, the vacuum path, and the sensor against the sample. Reference configuration, tags only.

    Every real oven is drawn for its own samples, its own atmosphere and its own room. These sheets are the arrangement and the order of working that a project set starts from. Approval of any drawing rests with the customer and the authority they name; none is claimed here.

    06
    Where it is used

    Wherever material is dried, aged or cured, and the temperature has to be the sample's.

    The common thread is a sample, a set temperature, a decision that rests on the result, and a sensor that sits somewhere else.

    Test laboratories

    Where samples are dried to a constant mass before they are weighed, and the result must repeat from one day to the next.

    Quality departments

    Where incoming material is dried and checked against a specification, and a sample dried unevenly gives a wrong number.

    Research and development centres

    Where new materials are dried gently under vacuum, aged or cured, and the temperature of the sample is part of the record.

    Workshops and component stores

    Where parts are dried after cleaning or conditioned before they are fitted, and an oven is a tool that must be trusted.

    07
    Watch

    See it in motion.

    A short walkthrough video of the Laboratory Oven.

    08
    FAQ

    Common questions.

    Longer answers, for readers who want the reasoning.

    Q · 01 What does a laboratory oven actually do?
    It holds a space at a set temperature, so that material can be dried, aged or cured. A hot-air oven has heaters and a fan that moves the heated air over the load. A vacuum oven takes the air away, so that a solvent or moisture leaves the material at a lower temperature, and it heats the load through its shelves. A controller and a sensor hold the set point, and a separate cut-out protects the oven if the controller fails. The oven does not decide what is dried or for how long. That comes from the customer's own procedure, and the oven is built, mapped and proved to carry it out.
    Q · 02 Why is the sensor not the sample?
    Because the controller reads one sensor at one point, and the sample sits somewhere else. The air at the sample is not exactly the air at the sensor, so the display shows the temperature of the sensor and not of the sample. After the door has been opened the difference is larger still, and the sample can lag behind the sensor for some time. A single check at the sensor shows that the control loop works. It does not show that the chamber is uniform. A map does, so the temperature is measured at many points, with the oven loaded, and the result says where a sample may be put.
    Q · 03 Why does a vacuum oven heat through the shelf, and why a cold trap?
    Because with the air taken away there is nothing to carry heat by convection. The heat reaches the sample through the shelf it stands on, so flat trays and good contact matter, and the sample is always a little behind the shelf. The lowered pressure lowers the boiling point of a solvent or of water, so that it leaves the material at a lower temperature, which suits material that heat or air would harm. The vapour then travels to the pump, where it would condense and spoil it. A cold trap between the oven and the pump collects the vapour first, and it is emptied when it is full.
    Q · 04 Why is the over-temperature cut-out separate, and what can it not do?
    Because a controller that fails can leave the heater on, and a cut-out that depends on the controller fails with it. The cut-out has its own sensor and sits in the heater supply, so it cuts the heater power on its own. It protects the oven and the load from a fault in the controller. It does not make an oven fit for a solvent that it was not made for, and it does not replace the operator's own judgement about what is put inside. The duty states what will be dried, and the oven is built for that.
    Q · 05 Is this the same as an environmental chamber, a hot-air generator or a vacuum pumping station?
    No, and the differences are worth stating precisely. The climatic and environmental test chambers page covers holding temperature and humidity for a test. The hot air generator page covers heating a stream of air for a process. The high vacuum pumping station page covers the pump station for a vacuum process. This page is the oven that dries, ages or cures material at a set temperature, with or without air. It does not replace any of them, and it does not claim what they claim a second time.
    Q · 06 Has Neometrix built one of these?
    We would rather answer this plainly than let a page imply otherwise. Neometrix has quoted against successive laboratory oven and vacuum oven requirements, and no delivered laboratory oven or vacuum oven is claimed. What stands behind the offer is adjacent: Neometrix engineers climatic and environmental test chambers (see the climatic and environmental test chambers page), a hot air generator (see the hot air generator page) and a high vacuum pumping station (see the high vacuum pumping station page). The heaters, the fan, the controller, the sensors, the vacuum pump and the seals are catalogue items, bought in, not invented. What Neometrix engineers is the oven around them: the chamber, the air path or the vacuum path, the protection and the proof. So the honest position is that the oven is engineered to order, the neighbouring disciplines are in the building, and the first oven of this exact kind will be built around the customer's own samples rather than taken off a shelf.
    Q · 07 Which standards apply, and what can the oven not do?
    ASTM E145 covers gravity-convection and forced-ventilation ovens and the way their temperature uniformity is judged, and IEC 61010-2-010 covers the safety of laboratory equipment for the heating of materials. This page prints none of their requirements, and no edition year: those come from the standard the customer names. The oven holds a set temperature. It does not decide what is dried, it does not make a sample reach the set point, and it does not replace the operator's own judgement. This page claims no certification or accreditation. No temperature, pressure, volume, time or power figure is printed here, and approval of an oven rests with the customer and the authority they name; none is claimed here.
    Q · 08 What do you need from us to quote?
    Six things, and most of them describe your samples rather than the oven. First, the material: what is dried, aged or cured, and in what form. Second, the temperature: the range, and how even it has to be across the load. Third, the atmosphere: air, vacuum or an inert gas, and what the material gives off. Fourth, the load: the size and the number of trays, and how often the door is opened. Fifth, the record: whether a map and a log are needed. Sixth, the place: the bench or the floor, the power supply and the access. From that we come back with an oven concept, a proving plan you can check, and a budgetary price.
    09
    Related

    The neighbouring pages, and how they differ from this one.

    Three neighbours: one holds temperature and humidity for a test, one heats a stream of air, one is the pump station for a vacuum.

    Browse all Neometrix product lines.

    Get a quotation

    Tell us the material,
    and where the sample will sit.

    The projects desk replies within two working days with an oven concept, a proving plan you can check, and a budgetary quotation. Write to [email protected] or use the form.

    Enquire — laboratory oven Capability sheet (PDF) +91 7777 876 876
    ISO 9001 / 14001 ENGINEERED-TO-ORDER CLASS — LABORATORY OVEN DUTY · CHAMBER AND SHELVES · HEAT AND AIR OR VACUUM · CONTROL AND CUT-OUT · BUILD · PROVE — THE SENSOR IS NOT THE SAMPLE. ENGINEERED IN NOIDA · INDIA

    Trending Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat
    move to top arrow