200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Neometrix / Fire Fighting Equipment / Remote-Controlled Fire Monitor / NMX-RFM-97
    NMX-RFM-97 · ENGINEERED-TO-ORDER CLASS — DUTY · MOUNT · DRIVES · CONTROL · BUILD · PROVE

    Remote-Controlled Fire Monitor. A jet pushes back.

    A remote-controlled fire monitor throws water or foam at a fire from a safe distance. An operator aims it from a control position, and no one has to stand in the heat. Neometrix engineers it as a system: the mount, the drives, the valve, the nozzle, the controller and the proof.

    So the monitor has to hold down against the push of its own jet, keep its aim where it was set, and stay under control when the signal is lost.

    A remote-controlled fire monitor on a plain white studio background: a pale grey pedestal pipe on a round bolted base flange with a square inlet branch, a bright stainless steel swivel housing with a black electric drive motor and a small black handwheel, a stainless barrel raised to point upward with a second black drive motor at its pivot, a plain stainless nozzle, and no water, no jet and no people
    Fig · 01 — A remote-controlled fire monitor: a pedestal on a bolted base, a swivel with its electric drive, a raised barrel with a second drive, and a nozzle at the end — illustrative render.
    The result
    a jet on the firethrown from a safe distance
    The mount
    held against the pushof the jet it throws
    The aim
    set, and heldby drives and a brake that do not creep
    The control
    a defined safe stateif the signal or the power is lost
    Status
    engineered to orderno delivered monitor claimed
    ISO 9001ISO 14001EN 15767 reference for portable monitors and nozzlesISO 12100 reference for machinery safety
    01
    Overview

    What a remote monitor has to get right, and what goes wrong when it does not.

    Because a jet is a strong force, and the monitor that throws it has to take that force without moving.

    A small fire-fighting robot on a plain white studio background: a low red painted steel body on two black rubber crawler tracks, a short bright stainless steel monitor on a swivel on top with a flared nozzle pointing upward, a plain hose inlet with a round coupling at the rear, two stainless outrigger feet lowered at the sides, and no water, no jet and no people
    Fig · 02 — A fire-fighting robot on a crawler base: a monitor on its swivel, the hose inlet at the rear, and outrigger feet that brace it against the push of the jet — illustrative render.

    A jet pushes back.

    What the monitor is for

    It puts a jet or a spray of water or foam onto a fire from a distance. It is aimed by remote control, so that no one has to stand in the heat. It serves process plants, hangars, ports and fire stations.

    Why a jet pushes back

    A jet leaving a nozzle pushes the nozzle the other way, as hard as it pushes the water out. The push grows with the flow and with the speed of the jet.

    Why the mount matters

    The push goes down through the barrel, the swivel and the pedestal into the mount. So the mount, and the structure under it, must resist it, in shear and in bending, with the monitor flowing at its full duty.

    Why a flat jet moves a base

    The flatter the jet, the more of the push is sideways. On a movable base a sideways push can slide the base or tip it. So the base is heavy, braced or anchored.

    Why the aim has to be held

    The push and the kick of the jet try to move the barrel. Drives that do not creep, and a brake, hold the aim where it was set, and position feedback shows it.

    Why the pressure is read at the nozzle

    The reach comes from the pressure and the flow at the nozzle, from the nozzle type and from the wind. A stream with too little pressure or flow is ineffective. So the pressure is read at the nozzle, and the supply is sized to the monitor.

    Why the valve moves at a controlled rate

    A valve that shuts fast on a flowing line sends a pressure surge back through the pipe. So the remote valve opens and closes at a controlled rate.

    Why the control has a safe state

    If the signal or the power is lost, the monitor must not swing on its own. It holds where it is, a manual override is at the unit, and a second control position can take over.

    Why the drives are protected

    Radiant heat from the fire reaches the monitor too. So the drives and the cables are shielded, or sited out of the heat path.

    02
    The method

    Duty, mount, drives, control, build and prove.

    Six steps in a fixed order. The mount and the proof are the two that a quick job skips.

    1 · Duty

    The fire risk, the water or foam supply, the distance to the fire, the place the monitor stands, and who aims it from where are noted.

    2 · Mount

    The push of the jet at full duty is carried through the pedestal into a mount or a base, and the structure under it is checked for shear and bending.

    3 · Drives and valve

    Electric or electro-hydraulic drives swing and raise the barrel and hold it. A remote valve opens and closes the supply at a controlled rate.

    4 · Nozzle and control

    The nozzle is chosen for the jet, the spray or the foam. The controller, wired or by radio, has a defined state if the signal or the power is lost.

    5 · Build

    The mount or base, the drives, the cables and the shielding are built and fitted, with a manual override at the unit.

    6 · Prove

    The monitor is run at full flow, the mount is checked under the jet, the loss of signal is tried, and the record goes with the monitor.

    Which hazard, which safeguard

    What can go wrongWhy it happensWhat the monitor does about it
    The monitor slides or tips when the jet startsthe jet pushes back, and more sideways when it is flata mount designed for the push, a base that is heavy, braced or anchored, and a valve that opens at a controlled rate
    The jet falls short of the firetoo little pressure or flow at the nozzle, or windpressure read at the nozzle, a supply sized to the monitor, and a nozzle chosen for the duty
    The aim wandersthe kick of the jet, or play in the drivesdrives that do not creep, a brake, and position feedback that shows where the barrel points
    Control is lostthe signal or the power failsa defined safe state, a manual override at the unit, and a second control position
    The drives are damaged by heatradiant heat from the fireshielding, heat-resistant cable, and drives sited out of the heat path
    A surge shakes the linea valve shuts fast on a flowing linea remote valve that opens and closes at a controlled rate

    The step people underrate is the mount. A monitor that aims well and is bolted to a weak structure will move the first time it throws its full jet.

    03
    Work content

    What the monitor contains, element by element.

    Read it as a checklist: a monitor missing a row will throw water, but it will not hold its aim against its own jet.

    The swivel and elevation drive of a fire monitor on a plain white studio background: a bright stainless steel swivel housing on a pale grey round base flange, a black electric drive motor with a round gear box and a small black handwheel, a stainless barrel section on a trunnion with a second black drive motor, a black housing beside the pivot, and no people
    Fig · 03 — The swivel and elevation drives: a motor and gear box with a handwheel for manual override, a second motor at the barrel pivot, and a housing beside the pivot for the position sensor — illustrative render.
    ElementWhat it doesWhat matters
    Barrel and swivelcarry the jet and turn ita barrel and a swivel that take the push of the jet at full duty, with seals that stay tight as the barrel turns
    Drivesswing and raise the barrelelectric or electro-hydraulic drives that hold the aim where it is set and do not creep under the push of the jet
    Brake and position feedbackhold and report the aima brake that holds the barrel, and feedback that shows where it points, so that the aim can be set and repeated
    Remote valveopens and closes the supplya valve operated by remote control that moves at a controlled rate, so that the line is not shaken by a surge
    Nozzleforms the jeta nozzle for a straight jet, a spray or foam, chosen for the duty, with the pressure read at the nozzle
    Mount and basecarry the pusha mount that resists the push in shear and in bending, or a base that is heavy, braced or anchored
    Controlleraims and sweepsa controller, wired or by radio, that aims the barrel, sweeps it over an arc, and has a defined state if the signal is lost
    Manual overrideworks if the power is losta means at the unit to move the barrel and close the valve by hand
    Protectionkeeps the drives workingshielding from radiant heat, heat-resistant cable, and enclosures that keep water and dirt out
    Supply connectionjoins the monitor to the water or foaman inlet made for the push and the pressure of the supply, with a strainer that keeps debris out of the valve and the nozzle
    Testing & documentationprove the monitor firsta flow test at full duty, a check of the mount under the jet, a loss-of-signal test, and a record the customer can inspect

    The elements that decide the result are the mount and base and the drives and brake. The first carries the push of the jet, and the second keeps the aim where it was set.

    Full specification — expand
    SystemA monitor barrel on a swivel, with electric or electro-hydraulic drives for swing and elevation that hold the aim, and a brake; position feedback; a remote valve that opens and closes at a controlled rate; a nozzle for jet, spray or foam; a mount or base that resists the push of the jet in shear and in bending; a controller, wired or by radio, with a defined state if the signal or the power is lost; a manual override at the unit; heat protection for the drives and cables; and load and flow testing and documentation before handover
    The One IdeaA jet pushes back.
    Why The Mount MattersA jet pushes its nozzle back as hard as it pushes the water out, and the push grows with the flow and the speed of the jet; it goes down through the barrel, the swivel and the pedestal into the mount, which must resist it in shear and in bending
    Why A Flat Jet Moves A BaseThe flatter the jet, the more of the push is sideways; on a movable base a sideways push can slide the base or tip it, so the base is heavy, braced or anchored
    StandardsEN 15767 covers portable monitors for fire service use, including their water nozzles, and ISO 12100 covers the general principles of design, risk assessment and risk reduction for machinery. This page prints none of their requirements, and no edition year. The mounting instructions for the monitor body that is fitted govern how it is held down. Approval of a monitor rests with the customer and the authority they name; none is claimed here
    ConfigurationsA fixed pedestal monitor, a movable monitor on a wheeled base, and a fire-fighting robot on a crawler base
    Scope BoundaryThis page is the remote-controlled fire monitor, which throws the water or the foam. It is not a hydrant and pump system, which supplies the water (see fire hydrant and pump system), not a foam proportioning system, which mixes the foam into the water (see foam proportioning system and mobile foam trolley) and not a water bowser, which carries the water (see tactical water bowser). It does not decide the fire plan, and it does not replace the fire officer's own judgement. No certification or accreditation is claimed here
    StatusNeometrix engineers remote-controlled fire monitors to order, and no delivered remote-controlled fire monitor is claimed.
    04
    Configurations

    One method, three ways to build the monitor.

    The method, the safety design, the control logic and the proof are shared. What changes is what carries the push of the jet, and where the monitor stands.

    Fixed pedestal monitor

    A monitor on a pedestal that is bolted to a structure built for the push of the jet

    For a place that is always at risk: a process plant, a hangar or a berth. The mount and the structure under it carry the push.

    Movable monitor on a wheeled base

    A monitor on a base that is moved to the fire, then braced or anchored

    For a risk that changes place: the base is heavy, braced or anchored before the jet is thrown, so that a sideways push cannot slide it.

    Fire-fighting robot on a crawler base

    A monitor on a remote-controlled crawler base, with the supply hose joined to it

    For a fire that no one can approach: the robot is driven to the fire, set down and braced, and then it aims and throws the jet from where it stands.

    And the part that is not equipment at all, yet decides all three: the duty and the fire plan. They are written from the customer's own risk, supply and site, not from the monitor.

    05
    The drawings

    A reference set, drawn as real CAD sheets.

    Two sheets of one reference configuration: the system schematic of a remote-controlled fire monitor, and the general arrangement of a fixed pedestal monitor with three details. They show the supply, the remote valve, the monitor body, the drives with their brakes and sensors, the controller and the safe state, the elevation and plan, the push of the jet going into the mount, and a movable base. They carry tags and letters only. Every flow, pressure, force, distance and quantity is fixed by design for the customer's duty.

    Reference drawing sheet one, the system schematic of a remote-controlled fire monitor. A supply of water or foam solution passes a strainer and a remote valve to the monitor body, which has a swivel, a barrel with an elevation joint and a nozzle, with a pressure gauge at the inlet and at the nozzle, on a mount. A controller and a second control position command the valve and two drives, each with a brake, a position sensor and a handwheel. A box states the safe state. A legend, a table of what each step does, seven notes and a title block stamped reference configuration, not for construction
    Fig · 04 — Sheet 01, the system schematic: the supply, a strainer, a remote valve, the monitor body on its mount, the two drives with their brakes, position sensors and handwheels, the controller and the safe state. Reference configuration, tags only.
    Reference drawing sheet two, the general arrangement and details of a fixed pedestal remote-controlled fire monitor. An elevation shows the base flange with its bolts, the pedestal pipe, the inlet branch, the swivel housing with its drive, the raised barrel with its drive and the nozzle. A plan shows the flange, its bolt circle, the pedestal, the inlet and the barrel. An item list numbers ten parts. Detail A shows the jet pushing the nozzle back and the push going down into the mount, Detail B how a flat jet pushes sideways, and Detail C a movable base braced against the push. A title block stamped reference configuration, not for construction
    Fig · 05 — Sheet 02, the general arrangement and details: the fixed monitor in elevation and plan, the push of the jet going into the mount, a flat jet pushing sideways, and a movable base braced against it. Reference configuration, letters only.

    Every real monitor is drawn for its own risk, its own supply and its own site. These sheets are the arrangement and the order of working that a project set starts from. The mounting instructions for the monitor body that is fitted govern how it is held down. Approval of any drawing rests with the customer and the authority they name; none is claimed here.

    06
    Where it is used

    Wherever a fire is too hot to approach, and the jet has to land.

    The common thread is a fire that people must stay away from, a supply that has to reach it, and a monitor that must not move when the jet starts.

    Process plants and storage

    Where a fire in a process unit or a storage area is too hot to approach, and a fixed monitor covers it from a safe place.

    Hangars and large buildings

    Where a large space has to be covered from a few points, and the monitor is aimed from a control room or a safe position.

    Ports and terminals

    Where a berth, a yard or a loading area is covered, and a movable monitor or a robot is brought to the fire.

    Fire stations and training

    Where crews learn to aim and hold a monitor by remote control, and the monitor is proved before it is trusted.

    07
    Watch

    See it in motion.

    A short walkthrough video of the Remote-Controlled Fire Monitor.

    08
    FAQ

    Common questions.

    Longer answers, for readers who want the reasoning.

    Q · 01 What does a remote-controlled fire monitor actually do?
    It throws a jet, a spray or foam onto a fire from a distance, and an operator aims it from a control position. A barrel on a swivel is swung and raised by electric or electro-hydraulic drives, a brake and position feedback hold and report the aim, and a remote valve opens and closes the supply at a controlled rate. A nozzle forms the jet. A controller, wired or by radio, aims the barrel and can sweep it over an arc. The monitor does not decide how a fire is fought. That comes from the fire plan, and the monitor is built, set and proved to carry it out.
    Q · 02 Why does a jet push back, and what does that mean for the mount?
    Because a jet leaving a nozzle pushes the nozzle the other way, as hard as it pushes the water out. The push grows with the flow and with the speed of the jet. It goes down through the barrel, the swivel and the pedestal into the mount, so the mount and the structure under it must resist it in shear and in bending, with the monitor flowing at its full duty. On a movable base it matters more. The flatter the jet, the more of the push is sideways, and a sideways push can slide the base or tip it. So the base is made heavy, braced or anchored before the jet is thrown.
    Q · 03 Why does the aim have to be held, and how?
    Because the push and the kick of the jet try to move the barrel, and a jet that wanders does not reach the fire. The drives are chosen so that they do not creep under that load, a brake holds the barrel where it is set, and position feedback shows where it points, so that an aim can be set again and repeated. When the barrel is made to sweep over an arc, the sweep is a controlled movement and not a drift. The controller reads the feedback, and the fitter can see the aim from the control position.
    Q · 04 What happens if the signal or the power is lost?
    The monitor must not swing on its own. Its safe state is defined when it is designed: it holds where it is, and the brake holds the barrel. A manual override at the unit moves the barrel and closes the valve by hand, and a second control position can take over the aim. The state is tried before handover by cutting the signal and the power on purpose. A monitor that has never been tested that way has not been proved. The remote valve also moves at a controlled rate, so that closing it does not send a surge through the line.
    Q · 05 Is this the same as a hydrant system, a foam proportioner or a water bowser?
    No, and the differences are worth stating precisely. The fire hydrant and pump system page covers supplying the water. The foam proportioning system and mobile foam trolley page covers mixing the foam into the water. The tactical water bowser page covers carrying the water. This page is the remote-controlled fire monitor, which throws the water or the foam. It does not replace any of them, and it does not claim what they claim a second time.
    Q · 06 Has Neometrix built one of these?
    We would rather answer this plainly than let a page imply otherwise. Neometrix engineers remote-controlled fire monitors to order, and no delivered remote-controlled fire monitor is claimed. What stands behind the offer is adjacent: Neometrix engineers a fire hydrant and pump system (see the fire hydrant and pump system page), a foam proportioning system (see the foam proportioning system and mobile foam trolley page) and a water bowser (see the tactical water bowser page). The monitor barrel, nozzles, valves, drives, cables and enclosures are catalogue items, bought in, not invented. What Neometrix engineers is the system around them: the mount and the base, the control and its safe state, the robot base, the protection and the proof. So the honest position is that the monitor is engineered to order, the neighbouring disciplines are in the building, and the first monitor of this exact kind will be built around the customer's own risk, supply and site rather than taken off a shelf.
    Q · 07 Which standard applies, and what can the monitor not do?
    EN 15767 covers portable monitors for fire service use, including their water nozzles, and ISO 12100 covers the general principles of design, risk assessment and risk reduction for machinery. This page prints none of their requirements, and no edition year: those come from the standard the customer names. The mounting instructions for the monitor body that is fitted govern how it is held down. The monitor throws the water or the foam. It does not decide the fire plan, it does not supply or mix anything, and it does not replace the fire officer's own judgement. This page claims no certification or accreditation. No flow, pressure, force, distance or quantity figure is printed here, and approval of a monitor rests with the customer and the authority they name; none is claimed here.
    Q · 08 What do you need from us to quote?
    Six things, and most of them describe your risk rather than the monitor. First, the fire risk: what burns, where, and how far the monitor stands from it. Second, the supply: the water or the foam, and what the supply can deliver at the monitor. Third, the place: whether the monitor is fixed, moved, or driven, and what it stands on. Fourth, the control: who aims it, from where, and by wire or by radio. Fifth, the conditions: heat, wind, dust and weather at the site. Sixth, the use: how often it is run, and by whom. From that we come back with a monitor concept, a test plan you can check, and a budgetary price.
    09
    Related

    The neighbouring pages, and how they differ from this one.

    Three neighbours: one supplies the water, one mixes the foam, one carries the water.

    Browse all Neometrix product lines.

    Get a quotation

    Tell us the risk,
    and the supply behind it.

    The projects desk replies within two working days with a monitor concept, a test plan you can check, and a budgetary quotation. Write to [email protected] or use the form.

    Enquire — fire monitor Capability sheet (PDF) +91 7777 876 876
    ISO 9001 / 14001 ENGINEERED-TO-ORDER CLASS — REMOTE-CONTROLLED FIRE MONITOR DUTY · MOUNT · DRIVES · CONTROL · BUILD · PROVE — A JET PUSHES BACK. ENGINEERED IN NOIDA · INDIA

    Trending Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat
    move to top arrow