200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Neometrix / Hydrogen Test Systems / Supercritical Water Electrolysis Test Stand / NMX-SCE-127
    NMX-SCE-127 · UNDER CONTRACT — PRESSURISE · HEAT · RUN · COOL · LET DOWN

    Supercritical Water Electrolysis Test Stand. Pressure first.

    Above about 374 °C and 221 bar, pure water is neither a liquid nor a gas but a single supercritical fluid. Neometrix engineers the test stand that takes an alkaline electrolysis cell there and back: a pressure vessel, a high-pressure feed, heaters, coolers, let-down valves, separators, instruments and controls.

    So the stand has to know that pressure goes up before temperature, that the way down runs in reverse, and that hydrogen and oxygen must be kept apart.

    A laboratory test stand on a plain white studio background: a thick-walled upright stainless pressure vessel with a bolted lid on a pale grey steel skid, two coil coolers in clear jackets, two upright separator vessels, a small pump and reservoir and a closed control cabinet, with no people
    Fig · 01 — A supercritical water electrolysis test stand: pressure vessel, pump, two outlet lines and controls — illustrative render.
    Order of work
    pressure firstthen heat, never the other way
    Pure water
    374 °C, 221 barits critical point, about
    Gas outlets
    kept aparthydrogen and oxygen
    The load
    on the vesseldesigned to a pressure code
    Status
    under contractno delivery is claimed
    ISO 9001ISO 14001The pressure code and the inspecting body are fixed in the order
    01
    Overview

    What changes above the critical point, and what the stand must hold.

    Water electrolysis is usually run on liquid water. Research above the critical point asks what happens when there is no liquid surface left to boil.

    A close view on a plain white studio background: a thick stainless pressure vessel with a ring of heavy studs, its lid raised on two guide columns, small tube fittings and insulated lead-throughs on the lid, with no people
    Fig · 02 — The pressure vessel that holds the cell, with its lid raised — illustrative render.

    Pressure first, then heat.

    What the stand is for

    It lets a researcher run water electrolysis below and above the critical point and record what changes: voltage and current at the cell, temperatures, pressures, flows and gas leaving.

    Why pressure comes first

    Above its critical pressure, water passes from liquid to supercritical on heating without ever boiling. Heat it at low pressure and it flashes into steam on the way.

    Why the electrolyte matters

    Dissolved salts move the critical point upward, as measurements on salt water show. An alkaline solution needs values established for its own strength, not read from tables for pure water.

    Why the materials are chosen with care

    Hot alkaline water attacks many metals. Wetted parts are commonly nickel-based alloys, chosen against the temperature and the solution and supported by material certificates.

    Why it is a pressure vessel first

    Hot fluid held at this pressure stores a great deal of energy. The vessel is designed to a recognised code, protected by relief devices and examined by an inspecting body.

    Why the cell can stay light

    One long-used arrangement puts the cell inside the vessel and keeps the pressure outside it close to the pressure inside, so the vessel carries the load.

    Why there are two outlets

    Hydrogen and oxygen leave in separate lines. Each is cooled, let down to low pressure and separated from the liquid before the gas is vented or measured.

    Why so much is recorded

    Temperatures, pressures, flows in and out and liquid levels are logged together. A difference between what goes in and what comes out may be the first sign of a leak.

    Why it is not a stack tester

    A stack tester grades a product at the conditions it is made for. This stand is a research machine for conditions far beyond those.

    02
    The method

    Prove tight, pressurise, heat, run, cool and let down.

    Six steps in a fixed order. The sequence matters as much as the hardware, so the controls hold it rather than leaving it to memory.

    1 · Prove tight

    The loop is filled, purged and pressure checked while everything is cold, so that a leak is found before anything is hot.

    2 · Pressurise

    The pressure is raised above the critical value of the solution, with margin, so that heating never meets a boiling point.

    3 · Heat

    Electrolyte and vessel are heated at a controlled rate while temperatures are compared, so that thick metal is not shocked.

    4 · Run

    Current is applied to the cell and each condition is held steady, so that a change in the result can be traced to a change in the setting.

    5 · Cool

    The current is switched off and the loop is cooled while still under pressure, so that nothing flashes into steam on the way down.

    6 · Let down and flush

    Only then is the pressure released, the lines purged with inert gas and flushed, so that the next run starts clean.

    What can go wrong, and what the stand does

    What can go wrongWhy it happensWhat the stand does
    Water flashes into steamheating before pressure, or pressure lost while hotheating is allowed only while the pressure is established
    The cell body is crushed or burstpressure inside and outside the cell drifts apartthe difference is measured and controlled through heat-up and cool-down
    Hydrogen and oxygen come togethera pressure or level upset pushes gas the wrong wayseparate lines, watched levels, inert purge and a shutdown
    A joint leaks as it heatsparts of the joint expand by different amountsa cold proof first, then gas detection and a pressure watch during heating
    A line blocksdeposits from corrosion or from the electrolytepressures along the line are compared, and relief devices protect it
    Metal wastes awaythe alloy does not suit hot alkaline watercertified materials, and inspection of wetted parts between campaigns
    A flow reading driftsdensity changes strongly near the critical pointflow is measured where the liquid is cold, and calibrated
    Power or control is losta mains or controller failurevalves move to their safe state, and relief devices need no power

    The mistake that costs most is the order. A heater switched on before the pressure is there turns a test loop into a boiler it was never meant to be.

    03
    Work content

    What the stand contains, element by element.

    Read it as a checklist: a stand missing a row may still heat water, but it will not do so safely or give a result that can be trusted.

    One outlet line on a plain white studio background: a polished coiled tube cooler in a clear jacket, a compact motor-driven valve and an upright stainless separator vessel, joined by bent steel tubing on a pale grey frame, with no people
    Fig · 03 — One of the two outlet lines: cooler, let-down valve and separator — illustrative render.
    ElementWhat it doesWhat matters
    Pressure vesselholds the cell and carries the loaddesigned to a pressure code, with a lid that can be opened and resealed many times
    Electrical lead-throughstake current and signals through the wallinsulated and gas-tight at temperature, sized for the cell's current
    Electrolyte reservoirsupplies the solutionresistant to the alkali, with level reading and a safe way to fill and drain
    High-pressure feed pumpraises and holds the flowa steady flow, and protection against hot fluid running backwards
    Heatersbring fluid and vessel to temperaturecontrolled rate, with an independent over-temperature cut-out
    Coolersbring each outlet back to a safe temperatureenough duty for the full flow, with the cooling water supervised
    Let-down valvestake each line from high pressure to lowfine control, because they also set the loop pressure
    Separatorspart the gas from the liquidone per gas, with level reading and an inert purge
    Inert gas systempressurises, purges and protectsregulated supply with relief, and no path for the two product gases to meet
    Instrumentsread the loop and the celltemperature, pressure, flow, level and gas detection, each calibrated
    Controls and softwarerun the sequence and recordthe order of steps enforced, interlocks, and time-stamped logging
    Safety devicesact when control cannotrelief valves, bursting discs, a vent to a safe place and an emergency stop

    The elements that decide whether the stand can be used are the pressure vessel and the control sequence. One holds the conditions, and the other brings the loop to them safely.

    Full specification — expand
    SystemA pressure vessel that holds the cell; electrolyte reservoir and high-pressure feed; heaters; two gas outlet lines with coolers, let-down valves and separators; inert gas for pressure and purge; insulated electrical lead-throughs; instruments; controls, interlocks and data logging; relief devices and venting
    The One IdeaPressure first, then heat.
    Why Pressure FirstAbove its critical pressure, water passes from liquid to supercritical on heating without ever boiling; dissolved electrolyte moves the critical point, so the margin is set for the solution
    Why Two OutletsHydrogen and oxygen are carried away in separate lines so that they are not brought together
    StandardsEN 13445 and the ASME Boiler and Pressure Vessel Code, Section VIII, are examples of public pressure vessel codes. The code, the inspecting body and the hazardous-area rules are fixed in the order. No certification or approval is claimed here
    ConfigurationsElectrode and materials studies, a complete cell inside the vessel, and one stand run below and above the critical point
    Scope BoundaryThis page is the supercritical water electrolysis test stand, a research machine. It is not a stack tester (see electrolyser test station), not a materials loading machine (see hydrogen embrittlement test system) and not a plant that makes hydrogen to use (see green hydrogen generation plant). It does not promise a better electrolyser: finding out is its job
    StatusNeometrix has a supercritical water electrolysis test stand under contract for a research institution, and no delivered stand is claimed.
    04
    Configurations

    One loop, three ways of using it.

    The pump, coolers, separators and controls are shared in principle. What changes is the vessel, what goes inside it and how wide a range the stand has to cover.

    Electrode and materials studies

    For single electrodes and coupons

    A small vessel with quick access, so that electrode materials and surface treatments can be exposed, powered and examined run after run.

    A cell inside the vessel

    For the researcher's own cell

    A larger vessel that takes a complete cell, with its electrolyte connections and power leads brought through the wall and the pressure difference watched.

    Below and above the critical point

    For comparing across the range

    One stand run from ordinary alkaline conditions up to supercritical ones, so that the same cell is observed on both sides of the line.

    And the part that is not equipment at all, yet decides all three: the conditions the research needs. Temperature, pressure, electrolyte and current fix the vessel and everything around it.

    05
    The drawings

    A reference set, drawn as real CAD sheets.

    Two sheets of one reference configuration, drawn from general practice: the arrangement of a supercritical water electrolysis test stand, and the order of work with the curves behind it. They show the feed path, the pressure vessel, the cell, the two gas lines and the interlocks. They carry tags and letters only. The boiling line and the wall stress are computed. Every operating condition and limit comes from the research programme, the pressure code and the hazard study.

    Reference drawing sheet one, the arrangement and details of a supercritical water electrolysis test stand. An electrolyte reservoir feeds a high-pressure pump with a check valve, a flow meter and a heater. A pressure vessel with a heating jacket holds the cell, supplied by a power source and an inert gas line with a relief valve and a bursting disc. Two separate gas lines leave the cell, each with a cooler, a let-down valve and a separator, and each vents on its own past a gas detector. A controller reads the sensors. Detail A shows the vessel in section with the cell on supports. Detail B shows one outlet line. Detail C shows the idea of the interlocks. An item list numbers twelve parts. A title block stamped reference configuration, not for construction
    Fig · 04 — Sheet 01, the arrangement: one feed path, the vessel with the cell, two separate gas lines and the interlocks. Reference configuration, tags only.
    Reference drawing sheet two, the sequence and the curves of a supercritical water electrolysis test stand. A sequence of boxes shows the work: prove tight, pressurise, heat, run, cool, and let down and flush. Detail A is a computed plot of pressure against temperature for pure water: the path that raises pressure first passes above the critical point without meeting the boiling line, while the path that heats first meets it and boils. Detail B shows the order in time, with pressure first up and last down. Detail C is a computed plot of stress through a thick vessel wall, highest at the bore. A title block stamped reference configuration, not for construction
    Fig · 05 — Sheet 02, the sequence and the curves: why pressure comes first, the order in time and the stress in the wall. Reference configuration, tags only.

    Every real stand is drawn for its own cell, its own conditions and its own laboratory. These sheets show a general arrangement and order of working, not a project design. Approval of any drawing rests with the customer and the authority they name; none is claimed here.

    06
    Where it is used

    Wherever hydrogen research goes past the boiling curve.

    The common thread is a question that ordinary electrolyser test equipment cannot reach, because it stops where water is still a liquid.

    Academic laboratories

    Where long research projects need a stand that runs the same sequence safely every time and records enough to publish from.

    Research institutes

    Where new electrolysis routes are screened and the effect of pressure and temperature on efficiency is measured rather than assumed.

    Electrolyser developers

    Where a cell concept for high temperature and pressure has to be tried in a controlled vessel before anyone builds a stack of it.

    Materials and corrosion groups

    Where alloys, seals and insulators are judged in hot alkaline water, with the conditions logged beside every specimen.

    07
    Watch

    See it in motion.

    A short walkthrough video of the supercritical water electrolysis test stand.

    08
    FAQ

    Common questions.

    Longer answers, for readers who want the reasoning.

    Q · 01 What does a supercritical water electrolysis test stand do?
    It creates and holds the conditions in which a researcher wants to electrolyse water, and records what happens there. An electrolyte is pumped to high pressure, heated and led to a cell inside a pressure vessel. Current is applied. Hydrogen and oxygen leave in separate lines, where each is cooled, let down to low pressure and separated from the liquid. Temperatures, pressures, flows and levels are logged, and interlocks stop the run if the loop leaves its limits.
    Q · 02 Why pressure first, then heat?
    Because of the boiling curve. Heat water at ordinary pressure and it boils, turning part of the liquid into steam with a large change of volume. Raise the pressure above the critical value first and then heat, and there is no such step: the liquid thins gradually and becomes supercritical. On the way down the same rule runs in reverse. The loop is cooled while it still holds pressure, and only then is the pressure released.
    Q · 03 What is different about water above its critical point?
    For pure water there is no longer a separate liquid and gas, only one fluid whose density depends strongly on pressure and temperature. Its ability to keep dissolved salts apart as ions falls sharply, so an electrolyte may conduct quite differently from the way it does when cold. Reactions may also run faster at higher temperature. Which of these effects wins in a real cell is not something this page claims to know. It is the question the research is built to answer.
    Q · 04 Do the figures for pure water apply to the electrolyte?
    No. The values of about 374 degrees Celsius and 221 bar belong to pure water. Dissolving a salt moves the critical point to a higher temperature and pressure, as measurements on solutions of ordinary salt show. An alkaline solution has its own behaviour, which depends on its strength. The stand is therefore rated with margin, and the conditions at which a given solution becomes supercritical are established for that solution rather than borrowed from water tables.
    Q · 05 Is this the same as an electrolyser test station?
    No, and the difference is worth stating precisely. The electrolyser test station page covers a bench that grades a stack at the conditions it is made for, with polarisation, impedance, per-cell voltage and gas crossover. This page is a research stand built around a pressure vessel and a high-pressure, high-temperature loop. The hydrogen embrittlement test system loads metal in hydrogen, and the green hydrogen generation plant makes hydrogen for use. It does not claim what they claim a second time.
    Q · 06 Has Neometrix built one of these?
    We would rather answer this plainly than let a page imply otherwise. Neometrix has a supercritical water electrolysis test stand under contract for a research institution, and no delivered stand is claimed. So the work is real and on order, but it has not yet been proven in service, and this page reports no test result from it. Pumps, valves, heaters, instruments and control hardware are catalogue or specialist items, bought in, not invented. What Neometrix engineers is the stand around them: the vessel arrangement, the piping, the safety system, the controls, the software and the proof.
    Q · 07 Which codes apply, and what can the stand not do?
    The pressure vessel and piping are designed to a recognised pressure code. EN 13445 and the ASME Boiler and Pressure Vessel Code, Section VIII, are examples; the code, the inspecting body and the hazardous-area rules for hydrogen are fixed in the order. This page claims no certification or approval, and prints no performance figure for any electrolysis cell. The stand cannot tell you in advance that supercritical electrolysis will be better. It can only let you measure it under conditions that are known and repeatable.
    Q · 08 What do you need from us to quote?
    Six things, and most of them describe your research rather than the stand. First, the cell: its size, shape and connections. Second, the conditions: the highest temperature and pressure you need together. Third, the electrolyte: what it is and how strong. Fourth, the power: the current and voltage, and who supplies the source. Fifth, the measurements: what has to be recorded and how often. Sixth, the laboratory: power, cooling water, gases, ventilation, floor load and the doors on the way in. From that we come back with a system concept, a safety outline and a budgetary price.
    09
    Related

    The neighbouring pages, and how they differ from this one.

    Three neighbours: one grades stacks, one tests metal in hydrogen, one makes hydrogen.

    Browse all Neometrix product lines.

    Get a quotation

    Tell us the cell,
    and the conditions you want to reach.

    The projects desk replies within two working days with a system concept, a safety outline and a budgetary quotation. Write to [email protected] or use the form.

    Enquire — test stand Capability sheet (PDF) +91 7777 876 876
    ISO 9001 / 14001 UNDER-CONTRACT CLASS — SUPERCRITICAL WATER ELECTROLYSIS TEST STAND PRESSURISE · HEAT · RUN · COOL · LET DOWN — PRESSURE FIRST, THEN HEAT. ENGINEERED IN NOIDA · INDIA

    Trending Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat
    move to top arrow