200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Neometrix / Life Support Test Equipment / Breathing Regulator Test Rig / NMX-BRT-125
    NMX-BRT-125 · ENGINEERED-TO-ORDER CLASS — MOUNT · SEAL · STATIC CHECKS · BREATHE · GO DEEP · JUDGE

    Breathing Regulator Test Rig. The loop is the effort.

    A breathing regulator is judged by the effort it asks of the person who breathes through it. Neometrix engineers the breathing regulator test rig that measures that effort: a breathing machine, a test chamber for depth, a controlled supply, pressure sensors and software that draws the loop.

    So the rig has to know that cracking pressure is only the start of a breath, the effort grows with flow and with depth, and a regulator without leaks can still be hard to breathe from.

    A breathing regulator test rig on a plain white studio background: a stainless steel pressure test chamber with a round hinged door, a breathing machine with a clear cylinder and piston on a steel frame, a small supply panel with black-handled valves, one pale grey gas cylinder and a small black demand regulator on its hose lying in front, with no people
    Fig · 01 — A breathing regulator test rig: a test chamber for depth, a breathing machine, a supply panel and a gas cylinder — illustrative render.
    The loop
    is the effortpressure at the mouth against volume
    Cracking
    is only the startthe first pull that opens the valve
    Depth
    makes gas denseso the same breath costs more
    The supply
    must be watchedfull cylinder and nearly empty
    Status
    engineered to orderno delivery is claimed
    ISO 9001ISO 14001The standard and the limits come from the set the regulator belongs to
    01
    Overview

    What a regulator test has to measure, and why one number is not enough.

    A regulator can open gently and still tire its wearer. What matters is the whole breath, at the rate and depth the set will be used.

    A breathing machine on a plain white studio background: a smoke-tinted clear cylinder with a steel piston on a rod driven by a black electric actuator on a stainless steel frame, a black corrugated breathing hose running to a small round black demand regulator on a post above it, and a small black sensor block, with no people
    Fig · 02 — A breathing machine joined to a demand regulator on a post above it — illustrative render.

    The loop is the effort.

    What the rig is for

    It proves that a demand regulator gives gas when asked, closes when the breath ends and does not tire the wearer. The result is recorded, not judged by feel.

    Why breathe through it

    A demand valve behaves differently under a moving breath than under a steady pull. A breathing machine repeats the same breath every time, so two regulators can be compared fairly.

    Why cracking pressure is not enough

    Cracking pressure is the small suction that first opens the valve. It says nothing about what happens at the fastest part of the breath, where most of the effort is spent.

    Why a rising and falling flow

    A person does not breathe at a steady flow. The flow rises, peaks and falls, so the rig draws it the same way and records the pressure throughout.

    Why depth

    Under water the gas is breathed at a higher pressure, so it is denser. Dense gas meets more resistance in narrow passages, and the same breath costs more work.

    Why hold the supply

    The first stage must feed the demand valve with a full cylinder and with a nearly empty one. The rig sets the supply and watches the pressure between the stages.

    Why breathing out matters

    A stiff or small exhaust valve makes breathing out hard. A leaking one lets water or smoke in. Both halves of the loop are judged.

    Why check leaks and free flow

    A valve that does not close empties the cylinder. Leak checks in both directions and a watch for free flow come before any breathing run.

    Why it is not a mask bench

    A mask bench looks at the fit and the valves of a mask. This rig looks at the regulator that meters the gas, breathing through it as a person would.

    02
    The method

    Mount, seal, check, breathe, go deep and judge.

    Six steps in a fixed order. The static checks come first, because a leaking or free-flowing regulator gives a loop that means nothing.

    1 · Mount

    The regulator goes on the mouthpiece or mask adapter and the supply is connected. Its settings are noted as found, so that the test describes the unit as it stands.

    2 · Seal

    Leak checks under suction and under pressure prove the joints, the diaphragm and the exhaust valve, so that a leak is not mistaken for easy breathing.

    3 · Static checks

    Cracking pressure, the pressure between the stages, its creep and the relief are measured at rest, so that a wrong setting is found before the machine runs.

    4 · Breathe

    The breathing machine runs at the rates asked, and mouth pressure is recorded against volume, so that each breath draws its own loop.

    5 · Go deep

    The chamber is pressurised to the test depth and the runs repeat, with the supply high and then low, so that the hardest case is measured rather than assumed.

    6 · Judge and record

    The work of breathing and the peak pressures are compared with the limits that apply, and the loops are kept, so that the next test has something to compare with.

    Which fault, what the rig shows

    What can go wrongWhy it happensWhat the rig shows
    Hard to start a breaththe valve is set heavy or its seat sticksa deep suction spike at the start of breathing in
    Starved at hard workthe first stage or a passage cannot pass enough gassuction that deepens sharply at peak flow
    Free flowthe valve does not close or is set too lightflow that carries on after the breath ends
    Hard to breathe outa stiff or small exhaust valvea high pressure in the breathing-out half of the loop
    Water or smoke gets ina torn diaphragm or an exhaust valve that does not seata failed leak check under suction
    The supply side leaksa worn seal or a damaged hosea falling pressure on the isolated supply
    Worse when the cylinder runs lowthe first stage output moves with its inlet pressurea loop that grows as the supply is lowered
    Fine at the surface, hard at depththe gas is denser under pressurea loop area that grows with chamber pressure

    The result people read too quickly is the cracking pressure. It is one point at the start of the loop, and the effort is the whole area.

    03
    Work content

    What the rig contains, element by element.

    Read it as a checklist: a rig missing a row will still open a regulator, but it will not tell you how hard it is to breathe from.

    A test chamber on a plain white studio background: a horizontal stainless steel pressure vessel with its round door swung open, showing a small black demand regulator on a bright steel adapter inside, with plain tubing and black-handled valves on a pale grey frame, and no people
    Fig · 03 — A test chamber with its door open and a regulator on its adapter inside — illustrative render.
    ElementWhat it doesWhat matters
    Breathing machinedraws a repeating breatha piston with a set tidal volume and rate, its motion smooth enough not to add noise to the pressure
    Mouth adapterholds the regulatora mouthpiece or mask adapter with a pressure tapping at the mouth and little dead space
    Test chamberreproduces deptha pressure vessel with its own approvals, a window, a relief and a door interlock
    Supply panelfeeds the first stagea controlled supply pressure from high to low, with isolation, a relief and clean fittings
    Mouth pressure sensormeasures the efforta fast, fine-range sensor close to the mouth, zeroed before each run
    Volume measurementgives the other axisbreathed volume from the piston position, recorded with the pressure at the same instant
    Interstage sensorwatches the first stageits set value, its drop under demand and its creep after the breath
    Leak test setproves the jointssuction and pressure checks with a measured decay, before any breathing run
    Temperature enclosuresets the surroundingscold water or cold air where the project's standard asks for it
    Gas cleanlinesskeeps the regulator fit for usebreathing-quality gas, and oxygen-clean parts where the regulator works on oxygen
    Controls and softwarerun and recorda sequence that draws each loop, works out the work of breathing and writes the report
    Safetyprotects people and partschamber relief and interlock, guarded piston, emergency stop and safe venting

    The elements that decide the result are the breathing machine and the mouth pressure sensor. The first makes the breath repeatable, and the second records what the wearer would feel.

    Full specification — expand
    SystemA breathing machine with set tidal volume and rate; a mouthpiece or mask adapter; a test chamber for depth with a window and relief; a supply panel with controlled supply pressure; mouth, interstage and supply pressure sensors; volume from the piston; a leak test set; controls, data acquisition and software that draws the loop; and a proving run and documentation before handover
    The One IdeaThe loop is the effort.
    Why The LoopMouth pressure plotted against breathed volume encloses an area, and that area is the work of breathing over the whole breath, not only at its start
    Why DepthGas becomes denser as the surrounding pressure rises, so the same breathing rate meets more resistance and the loop grows
    StandardsEN 250 for open-circuit compressed air diving apparatus and EN 137 for self-contained compressed air breathing apparatus are examples of public standards that cover breathing performance. The project's own standard governs, with its limits and its test conditions. No certification, accreditation or approval is claimed here
    ConfigurationsBench check, breathing performance at the surface, and breathing performance at depth
    Scope BoundaryThis page is the breathing regulator test rig, which breathes through a demand regulator and measures the effort. It is not a pressure regulator bench or a mask rig (see oxygen component test benches), not a mask overhaul facility (see aircrew oxygen mask overhaul and test facility) and not the breathing apparatus itself (see breathing air systems and rescue sets). It does not certify a set: that rests with the authority the customer names
    StatusNeometrix engineers breathing regulator test rigs to order, and no delivered breathing regulator test rig is claimed.
    04
    Configurations

    One method, three depths of testing.

    The adapter, the supply and the sensors are shared. What changes is whether the regulator is breathed through, and at what surrounding pressure.

    Bench check

    For servicing and return to use

    Leak checks, cracking pressure, pressure between the stages, creep and relief, recorded for each unit on a compact bench.

    Breathing performance at the surface

    For apparatus breathed in air

    The bench check with a breathing machine, so that each regulator draws its loop at the breathing rates asked, with the supply high and low.

    Breathing performance at depth

    For diving regulators and type work

    The surface rig with a test chamber, so that the loop is measured while the surrounding pressure matches the depth, with cold conditions where asked.

    And the part that is not equipment at all, yet decides all three: the standard the set is held to. It sets the breathing rates, the depths, the limits and the record.

    05
    The drawings

    A reference set, drawn as real CAD sheets.

    Two sheets of one reference configuration: the arrangement of a breathing regulator test rig with three details, and the order of work with the curves that show why the loop is the effort. They show the supply, the demand regulator on its mouth adapter, the chamber, the breathing machine and the balance line. They carry tags and letters only. The curves are computed in relative units. Every rate, depth and limit comes from the standard of the set the regulator belongs to.

    Reference drawing sheet one, the arrangement and details of a breathing regulator test rig. A supply cylinder feeds a supply regulator and a first stage, then a demand regulator on a mouth adapter inside a test chamber with a window in its door. A breathing hose passes through the wall to a breathing machine, a piston driven by an actuator with a position sensor. A balance line joins the back of the piston to the chamber. The chamber has an inlet valve, a vent valve and a relief, and pressure sensors feed a data acquisition unit. Detail A shows the mouth adapter with its pressure tapping close to the regulator. Detail B shows the breathing machine, whose stroke is the tidal volume. Detail C shows the chamber with its window, relief, door interlock and sealed passages. An item list numbers twelve parts. A title block stamped reference configuration, not for construction
    Fig · 04 — Sheet 01, the arrangement: the supply, the regulator in the chamber, the breathing machine and the balance line, with three details. Reference configuration, tags only.
    Reference drawing sheet two, the sequence and the curves of a breathing regulator test rig. A sequence of boxes shows the work: mount, seal, static checks, breathe, go deep, and judge and record. Detail A is a computed loop of the pressure at the mouth against the breathed volume over one whole breath, at the surface and at depth, where the denser gas makes the loop larger. Detail B is a computed plot of the work of one breath against the breathing rate: it rises faster at depth and crosses an illustrative limit line that the surface curve stays under. Detail C is a computed plot of suction against flow for two regulators that open at the same pressure, one of which then asks far more. A title block stamped reference configuration, not for construction
    Fig · 05 — Sheet 02, the sequence and the curves: the order of work, one whole breath as a loop, the work against rate, and two regulators that open alike. Reference configuration, tags only.

    Every real rig is drawn for its own regulators, its own chamber and its own standard. These sheets are the arrangement and the order of working that a project set starts from. Approval of any drawing rests with the customer and the authority they name; none is claimed here.

    06
    Where it is used

    Wherever a breath depends on a valve that opens.

    The common thread is a person who gets gas only when a demand valve gives it, and who has to be able to trust it.

    Diving equipment workshops

    Where regulators are serviced and returned to divers, and each one needs a measured record rather than a breath on a bench by hand.

    Fire and rescue services

    Where the demand valves of compressed air breathing apparatus are checked after service, with positive pressure sets held to their own limits.

    Aircrew life support

    Where breathing regulators are overhauled and proven before they go back, with oxygen-clean parts where the regulator works on oxygen.

    Test laboratories

    Where designs are developed and compared, and the same breath has to be repeated exactly across many samples and many changes.

    07
    Watch

    See it in motion.

    A short walkthrough video of the breathing regulator test rig.

    08
    FAQ

    Common questions.

    Longer answers, for readers who want the reasoning.

    Q · 01 What does a breathing regulator test rig actually do?
    It proves a demand regulator before somebody relies on it. The regulator is mounted on a mouthpiece or mask adapter and fed from a controlled supply. Leak checks under suction and under pressure come first, then cracking pressure and the pressure between the stages. A breathing machine then draws a repeating breath through the regulator, and the pressure at the mouth is recorded against the breathed volume. A test chamber raises the surrounding pressure for depth runs. The software draws each loop, works out the work of breathing and writes the report against the limits that apply to that set.
    Q · 02 Why is the loop the effort?
    Because work is pressure acting through volume. When the wearer breathes in, the lungs pull a suction while volume enters. When the wearer breathes out, they push a pressure while volume leaves. Plot the pressure at the mouth against the volume for one whole breath and the line closes into a loop. The area inside it is the work the wearer has done to breathe through the regulator. A deep spike at the start, a heavy dip at peak flow and a high push on the way out all enlarge that area. One number taken at one moment cannot show them.
    Q · 03 Why is cracking pressure not enough?
    Cracking pressure matters, and the rig measures it. It is the small suction needed to open the valve, and a valve set too heavy tires the wearer from the first instant, while one set too light may free flow. But it is measured with almost no flow. The rest of the breath is different: as the flow rises, the passages, the lever, the diaphragm and the first stage all have to keep up. Two regulators with the same cracking pressure can ask for very different effort at the fastest part of the breath, and only a breathing run shows it.
    Q · 04 Why does depth matter, and how is it reproduced?
    Because a diver breathes gas at the pressure of the surrounding water. The deeper the dive, the higher that pressure, and the denser the gas. Dense gas flowing quickly through narrow passages meets more resistance, so a regulator that breathes easily at the surface can feel heavy at depth. The rig reproduces this by putting the regulator, or the whole breathing circuit, in a pressure chamber and raising the pressure to the test depth before the breathing runs. The chamber is a pressure vessel with its own approvals, a relief and a door interlock.
    Q · 05 Is this the same as an oxygen component bench, a mask facility or a breathing apparatus?
    No, and the differences are worth stating precisely. The oxygen component test benches page covers benches for pressure regulators, valves and masks, where a pressure regulator is judged for set point, droop and lock-up. The aircrew oxygen mask overhaul and test facility page restores and tests masks. The breathing air systems and rescue sets page covers the apparatus itself. This page is the rig that breathes through a demand regulator and measures the effort of every breath. It does not claim what they claim a second time.
    Q · 06 Has Neometrix built one of these?
    We would rather answer this plainly than let a page imply otherwise. Neometrix engineers breathing regulator test rigs to order, and no delivered breathing regulator test rig is claimed. What stands behind the offer is adjacent: the pages for the oxygen component test benches, the aircrew oxygen mask facility and the breathing air systems each describe equipment around breathing gas, and each states its own status. The sensors, the actuator, the valves and the data hardware are catalogue items, bought in, not invented. What Neometrix engineers is the rig around them: the breathing machine, the chamber, the supply, the adapters, the controls, the software and the proof. So the first rig of this exact kind will be built around the customer's own regulators.
    Q · 07 Which standard applies, and what can the rig not do?
    The standard of the set the regulator belongs to applies. EN 250 for open-circuit compressed air diving apparatus and EN 137 for self-contained compressed air breathing apparatus are public examples that cover breathing performance; other users have their own documents. No size, flow, pressure, depth, temperature or time figure is printed here: those come from that standard. The rig measures a regulator on a bench or in a chamber. It does not test the fit of a mask on a face, the wearer, or the whole dive. This page claims no certification or accreditation, and approval of equipment rests with the authority the customer names; none is claimed here.
    Q · 08 What do you need from us to quote?
    Six things, and most of them describe your regulators rather than the rig. First, the regulators: their types and how they connect. Second, the standard: the document and clauses the results are judged against. Third, the gas: air, oxygen or a mix, and its supply pressures. Fourth, the depth: whether chamber runs are needed, and how deep. Fifth, the surroundings: cold water, cold air or room conditions. Sixth, the record: what each report must show. From that we come back with a system concept, a proving plan you can check, and a budgetary price.
    09
    Related

    The neighbouring pages, and how they differ from this one.

    Three neighbours: one proves oxygen parts, one restores masks, one covers the apparatus.

    Browse all Neometrix product lines.

    Get a quotation

    Tell us the regulators,
    and the standard they answer to.

    The projects desk replies within two working days with a system concept, a proving plan you can check, and a budgetary quotation. Write to [email protected] or use the form.

    Enquire — regulator rig Capability sheet (PDF) +91 7777 876 876
    ISO 9001 / 14001 ENGINEERED-TO-ORDER CLASS — BREATHING REGULATOR TEST RIG MOUNT · SEAL · CHECK · BREATHE · GO DEEP · JUDGE — THE LOOP IS THE EFFORT. ENGINEERED IN NOIDA · INDIA

    Trending Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat
    move to top arrow