200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Neometrix / Cryogenic Test Facilities / Cryocooler Test Facility / NMX-CRY-111
    NMX-CRY-111 · ENGINEERED-TO-ORDER CLASS — DUTY · CRYOSTAT AND SHIELD · HEATER AND SENSORS · HELIUM AND VACUUM · FORCE AND TILT · BUILD · PROVE

    Cryocooler Test Facility. The rating is a curve, not a number.

    A cryocooler is a closed-cycle refrigerator: it cools one end far below room temperature and holds it there, with no supply of liquid. Neometrix engineers the facility that tests one as a whole: the vacuum cryostat, the shield, the heater and sensors, the gas and vacuum system and the record.

    So the facility has to know that a cryocooler's cooling power is a curve, not a number, keep the heat leaking in small and known, and hold each point until it is steady.

    A cryocooler test facility on a plain white studio background: an upright cylindrical bright steel vacuum cryostat on a pale grey steel base frame with a round bolted lid, a pale grey cold head standing on the lid, two thin black flexible gas hoses running from the cold head to a plain pale grey compressor cabinet on the floor at the right, a small black vacuum pump at the left with a braided hose rising to the side of the cryostat, a small pale grey junction box on a short stand with a thin black cable to the lid, and no people
    Fig · 01 — A cryocooler test facility: a vacuum cryostat with the cold head on its lid, two gas lines to the compressor, a vacuum pump and a junction box — illustrative render.
    The cooling power
    is a curveit falls as the cold end gets colder
    The load
    comes from a heaterone steady point at a time
    The heat leak
    is measured apartso it is not counted as cooling
    The way up
    is a test conditiona tilted cooler can behave differently
    Status
    engineered to orderno delivery is claimed
    ISO 9001ISO 14001Test conditions set by the customer and the cooler maker
    01
    Overview

    What a cryocooler test has to get right, and what goes wrong when it does not.

    Because the cold end is so well insulated, a small stray heat load looks like a large change in cooling, and a fault shows up as a curve that is not the curve the cooler really has.

    The cold stage of a cryostat on a plain white studio background: a short pale grey cold head on a round pale grey top plate held by a three-legged pale grey frame, a thick round bright steel cold plate hanging below it on three thin bright rods, a small black cylindrical heater block and two small bright steel sensor bodies on the plate with thin black wires, a polished bright steel open-ended cylindrical radiation shield lying on its side beside the frame, and no people
    Fig · 02 — The cold stage: a cold plate with a heater block and two sensors, and the radiation shield that goes over it — illustrative render.

    A cryocooler's cooling power is a curve, not a number.

    What the facility is for

    It holds a cryocooler at one cold temperature after another and reads what it can lift at each. It also records the power the cooler draws, the force it passes into its mount and how long it takes to get cold.

    How the curve is made

    A heater on the cold plate adds a known heat load. The cooler settles at a temperature where its cooling power equals the heater power plus the small heat that leaks in. Step the heater, wait for a steady temperature, and write the point down.

    Why the curve is not a number

    A data sheet gives one rating at one temperature. The cooling power is largest when the cold end is warm, and it falls to nothing at the coldest temperature the cooler can reach with no load. The same cooler can lift a great deal at one temperature and nothing at another.

    Why the leak must be known

    The vacuum, the shield and the wiring still let in some heat, by radiation, by conduction through the supports and wires, and through any gas left behind. It is measured in its own run, so that it is not counted as cooling.

    Why steady means steady

    A cold stage takes time to settle, and a point written down too early is a point on the way to somewhere else. The logger waits until the temperature has stopped drifting, and keeps the time each point took.

    Why the way up matters

    A pulse tube has no moving part at its cold end, but gas can circulate inside it under gravity. So its cooling can change when the cooler is tilted, and the cold end pointing down is usually the best case. A tilt stage lets the cooler be tested the way it will be mounted.

    Why the force is measured

    A cooler shakes its mount, and a sensitive detector or magnet can feel it. A force platform under the cooler records the force it passes into its mount, in three directions.

    Why a cooler test is not a chamber test

    It is not a thermal vacuum chamber, which holds a whole unit under vacuum at set temperatures. It tests the cooler itself, on a cold plate with a known load.

    02
    The method

    Duty, cryostat and shield, heater and sensors, gas and vacuum, force and tilt, build and prove.

    Six steps in a fixed order. The heater and sensors and the heat-leak run are the two that a quick job skips.

    1 · Duty

    The coolers to be tested, the cold temperatures and heat loads that matter, what is recorded, the room and the services, and the way the cooler will be mounted, are noted.

    2 · Cryostat and shield

    A vacuum cryostat holds the cold stage behind a radiation shield, with feedthroughs for the wires, so that the heat leaking in stays small and known.

    3 · Heater and sensors

    A heater and temperature sensors sit on the cold plate, wired so that the wires add almost no heat, with a kind of sensor that suits each temperature range.

    4 · Gas and vacuum

    A vacuum system pumps the cryostat down and keeps it there, and a helium line serves the cooler's own gas, with a leak check before every run.

    5 · Force and tilt

    A three-axis force platform records what the cooler passes into its mount, and a tilt stage holds it at set angles, so that the way up is a test condition.

    6 · Build and prove

    The facility is built and leak tested, the heater and sensors are checked against a reference, the heat leak is measured and written down, every interlock is tried, and the record goes with the facility.

    Which fault, which safeguard

    What can go wrongWhy it happensWhat the facility does about it
    The curve is not the cooler's curvethe heat leaking in was not known, or heat from the heater wires was counted as coolinga separate heat-leak run, a shield, and a record of the leak with every curve
    A point is on the way to somewhere elsethe reading was taken before the cold stage had settleda rule that waits until the temperature has stopped drifting, and a log of how long each point took
    The temperature is wrongthe sensor is poorly clamped to the plate, is the wrong kind for that range, or is warmed by its own wiressensors clamped with a good joint, the right kind for each range, and wires anchored to the shield
    The cold end will not get as cold as it shouldthe vacuum is poor, a leak has let gas in, or the working gas is not purea leak check before every run, a vacuum reading logged with the run, and a purity record for the helium
    The cooling changes when the cooler is movedgas circulates inside a pulse tube when it is tilteda tilt stage, and a curve taken at each angle the cooler will meet in use
    The mount shakesthe cooler passes force into its mount, and the detector or magnet feels ita three-axis force platform, and a record of the force at the cooler's own frequency and its multiples
    The cooler is slow to get coldthe load on the cold stage holds heat, or the cooler is not set up as it will be useda cool-down curve recorded from room temperature, with the same load on the plate every time
    Someone is near a charged linethe cooler's gas lines are at pressure while people work on thempressure relief on the gas circuit, guards over the lines, and a procedure that says nobody opens a charged line

    The step people underrate is the heat-leak run. A bench that never measured its own leak cannot say how much of the cooling it recorded was the cooler's.

    03
    Work content

    What the facility contains, element by element.

    Read it as a checklist: a facility missing a row will cool a cooler, but it will not give a curve that can be trusted and compared.

    A cryostat on a tilt stage on a plain white studio background: a cylindrical bright steel cryostat with a round lid and a pale grey cold head on top, held in a pale grey steel cradle with two side pivots and leaning to one side, the cradle standing on a flat square bright steel plate on four small black feet with one thin black cable, and no people
    Fig · 03 — The cryostat on its tilt stage, standing on the force platform — illustrative render.
    ElementWhat it doesWhat matters
    Vacuum cryostatholds the cold stage in vacuuma vessel with a lid that opens for a change of load, ports for the cooler, the wiring and the pumping, and a seal that holds
    Radiation shieldscreens the cold stage from the warm walla bright shield anchored to the first stage of the cooler, with layered insulation where the design calls for it
    Cold plate and loadcarry what is cooleda plate of known mass with a good thermal joint to the cold tip, so every run starts from the same load
    Heateradds the known heat loada resistive heater on the plate, driven by a steady supply, with its voltage and current read at the plate
    Temperature sensorsread the cold stagesensors of the right kind for each range, clamped to the plate and wired through the shield with the wires anchored
    Vacuum systemholds the vacuuma pump set, a vacuum reading and a valve, and a leak check before each run
    Gas circuitserves the cooler's own gasa helium line with a regulator, a relief valve and a vent, for the compressor circuit and the charge
    Compressor and heat rejectionrun the cooler and carry its heat awaythe cooler's own compressor, its input power read at the supply, and its heat taken away by cooling water or air
    Force platformrecords the force into the mounta three-axis platform under the cooler, and a mount that does not hide the signal
    Tilt stagesets the anglea frame that holds the cryostat at set angles, with the cold end pointing up, level and down
    Logger and controllerrun the pointsa sequence that steps the heater, waits for a steady temperature and records the point, with a log of every run and a controller apart from the cooler's own
    Testing & documentationprove the facility firsta leak test, the heater and sensors checked against a reference, the heat leak measured, every interlock tried, and a record the customer can inspect

    The elements that decide the result are the heater and sensors and the heat-leak run. The first makes each point known, and the second says how much of it was the cooler's.

    Full specification — expand
    SystemA vacuum cryostat with a radiation shield and a cold plate; a heater and temperature sensors on the plate; a vacuum system and a helium line with a set leak check before every run; the cooler's own compressor and heat rejection; a three-axis force platform and a tilt stage; a logger and controller that step the heater, wait for a steady temperature and record each point; guards and interlocks; and a proving run, an interlock check and documentation before handover
    The One IdeaA cryocooler's cooling power is a curve, not a number.
    Why The Curve Is NeededThe cooling power is largest when the cold end is warm and falls to nothing at the coldest temperature the cooler can reach with no load, so one rating at one temperature says little about the temperature that matters
    Why The Heat Leak MattersHeat leaks into the cold stage by radiation, by conduction through supports and wires and through any gas left in the vacuum. It is measured in its own run, so that it is not counted as cooling
    Why The Way Up MattersGas can circulate inside a pulse tube under gravity, so its cooling can change when the cooler is tilted. A tilt stage tests the cooler at the angles it will meet in use
    StandardsNo test standard is quoted here. The conditions to be reproduced are stated by the customer and the cooler maker, and approval of a cooler rests with the customer and the authority they name; none is claimed here. No certification or accreditation is claimed here
    ConfigurationsA performance bench, a vibration and orientation bench, and a life and soak bench
    Scope BoundaryThis page is the cryocooler test facility, which tests the cooler itself on a cold plate with a known load. It is not a thermal vacuum chamber, which holds a whole unit under vacuum at set shroud temperatures (see thermal vacuum chamber), not a helium charging station, which decants and recharges helium bottles (see helium charging station) and not a cryogenic liquid system, which stores and supplies liquids and gas (see cryogenic liquid and nitrogen gas systems). It does not certify a cooler, and it does not replace the operator's own judgement
    StatusNeometrix engineers cryocooler test facilities to order, and no delivered cryocooler test facility is claimed.
    04
    Configurations

    One method, three ways to build the facility.

    The method, the heat-leak run and the steady-state rule are shared. What changes is what sits under the cooler, what else is measured and how long the run lasts.

    Performance bench

    A curve for the cooler

    For rating a cooler: a vacuum cryostat with a shield, a heater and sensors on the cold plate, a helium line and a logger that steps the load and records the curve and the cool-down.

    Vibration and orientation bench

    The way it will be mounted

    For a cooler that goes into a sensitive instrument: a force platform under the cooler and a tilt stage, so that the force it passes into its mount and the way up are both tested.

    Life and soak bench

    A long run, one record

    For a cooler that must run for a long time: a bench that holds a set load for a long run and logs the temperature, the input power and the gas pressures, so that a slow drift is seen.

    And the part that is not equipment at all, yet decides all three: the conditions. The temperatures, loads and angles to be tested come from the customer's duty, not from the facility.

    05
    The drawings

    A reference set, drawn as real CAD sheets.

    Two sheets of one reference configuration: the arrangement of a performance and orientation bench with three details, and its helium, vacuum and measurement circuits with the curves that show why a cryocooler's cooling power is a curve, not a number. They show the cryostat, the cold stage and the wiring, and how the curve is made by stepping a heater. They carry tags and letters only. Every temperature, power, force and time is fixed by design for the customer's duty.

    Reference drawing sheet one, the arrangement and details of a cryocooler test facility. An elevation shows a vacuum cryostat on a tilt stage and a force platform, with a cold head on its lid, a radiation shield, a cold plate with a heater and two temperature sensors, and the wires anchored at the shield and taken out through a feedthrough; two helium lines run to a compressor with heat rejection, charged from a gas cylinder through a regulator with a relief valve; a vacuum line runs through a valve to a pump with a gauge; and a control bench holds a logger, a controller and a heater supply, with the signal lines drawn in. Detail A shows the cold stage in section. Detail B shows the heater wiring, with separate current leads and voltage leads anchored at the shield. Detail C shows the tilt stage with the cold end down, level and up. An item list numbers nine parts. A title block stamped reference configuration, not for construction
    Fig · 04 — Sheet 01, the arrangement: the cryostat on its tilt stage and force platform, the cold stage, the heater wiring and the three tilt positions. Reference configuration, letters only.
    Reference drawing sheet two, the circuits and the curves of a cryocooler test facility. A circuit shows a gas cylinder charging a compressor through a regulator and a valve, a relief valve and a transducer on the circuit, heat rejection, two helium lines to a cold head on a cryostat with a shield, a cold plate, a heater and a sensor, a vacuum line through a valve to a pump with a gauge, and a branch to a leak detector. A measurement chain runs from the sensors through a temperature monitor to a logger and a controller that steps a heater supply, with heater power, a force signal and compressor power also feeding the logger. Detail A is a computed plot of cooling power against cold temperature for two coolers that share one rating point but have different curves. Detail B is a computed plot of the settled points as the heater is stepped, with the heat leak. Detail C is a computed plot of the cold temperature through four heater steps, with a reading taken too early. A title block stamped reference configuration, not for construction
    Fig · 05 — Sheet 02, the circuits and the curves: two coolers with one rating, the heater steps and the wait for steady. Reference configuration, tags only.

    Every real facility is drawn for its own cooler, its own temperatures and its own room. These sheets are the arrangement and the order of working that a project set starts from. Approval of any drawing rests with the customer and the authority they name; none is claimed here.

    06
    Where it is used

    Wherever something has to be kept very cold without a liquid, and the cooler's reserve has to be known.

    The common thread is a detector, a magnet or an experiment that hangs on a cooler, and a cooling power that has to be known at the temperature the work runs at.

    Cooler makers

    Where a new cooler, or a change to one, has to be shown against its own rating before it is sold.

    Detector groups

    Where an infrared or X-ray detector is cooled, and the cooler has to hold it steady without shaking it.

    Magnet and superconductor groups

    Where a superconducting magnet or cable is cooled by a cooler instead of a bath of liquid, and the reserve of cooling has to be known.

    Research laboratories

    Where experiments run cold for a long time, and the cooler's curve decides what can be hung on it.

    07
    Watch

    See it in motion.

    A short walkthrough video of the cryocooler test facility.

    08
    FAQ

    Common questions.

    Longer answers, for readers who want the reasoning.

    Q · 01 What does a cryocooler test facility actually do?
    It measures what a cooler really delivers. A vacuum cryostat holds the cold plate behind a radiation shield, a heater adds a known load, and sensors read the temperature of the plate. The facility steps the heater, waits for the temperature to settle and records each point, so that the cooling power is plotted against the cold temperature. It also records the cool-down from room temperature, the power the compressor draws, the force the cooler passes into its mount and the change in cooling when the cooler is tilted. A logger keeps every run. The facility does not choose the test. That comes from the customer's own duty, and the facility is built, proved and recorded to carry it out.
    Q · 02 Why is cooling power a curve and not a number?
    Because a cooler lifts heat from a cold place and puts it out at room temperature, and the colder the cold place, the harder that is. Even an ideal machine would need more input for each unit of heat lifted as the cold end gets colder, and a real cooler falls short of the ideal by a margin that also changes with temperature. So the cooling power is largest when the cold end is warm, and it falls to nothing at the coldest temperature the cooler can reach with no load. A rating gives one point on that curve. If the work runs at another temperature, that point does not describe it, which is why the facility plots the whole curve and why the temperatures that matter are stated in the duty.
    Q · 03 Why does the heat leak matter so much?
    Because at the cold end a little heat is a large share of what the cooler can lift. Heat comes in by radiation from the warm wall, by conduction down the supports and the wires, and through any gas left in the vacuum. The cooler has to lift that as well as the load, so at a steady temperature its cooling power equals the heater power plus the leak. If the leak is not known, the curve is out by that much and nobody can tell. So the facility measures the leak in its own run, shields the cold stage, anchors the wires and logs the vacuum, and the result goes into the record with every curve.
    Q · 04 Why test a cooler on a tilt stage?
    Because some coolers do not behave the same in every position. In a pulse tube the gas can circulate inside the tube under gravity, and that carries heat the wrong way. The effect depends on the design and grows with the tilt, and the cold end pointing down is usually the best case. A cooler that goes into an instrument that is turned to different directions, or is fixed at an awkward angle, has to be tested at those angles. So the cryostat sits on a tilt stage, and a curve is taken at each angle the duty names. Which kinds of cooler are affected, and by how much, is for the cooler maker to say. The facility measures it.
    Q · 05 Is this the same as a thermal vacuum chamber, a helium charging station or a cryogenic liquid system?
    No, and the differences are worth stating precisely. The thermal vacuum chamber page covers a chamber that holds a whole unit under vacuum at set shroud temperatures. The helium charging station page covers decanting and recharging helium bottles. The cryogenic liquid and nitrogen gas systems page covers storing and supplying liquids and gas. This page is the facility that tests a cooler itself, on a cold plate with a known load, and records its curve. It does not replace any of them, and it does not claim what they claim a second time.
    Q · 06 Has Neometrix built one of these?
    We would rather answer this plainly than let a page imply otherwise. Neometrix engineers cryocooler test facilities to order, and no delivered cryocooler test facility is claimed. What stands behind the offer is adjacent: Neometrix engineers a thermal vacuum chamber (see the thermal vacuum chamber page), a helium charging station (see the helium charging station page), a helium leak detection system (see the helium leak detection system page) and cryogenic liquid and nitrogen gas systems (see the cryogenic liquid and nitrogen gas systems page). The temperature sensors, the heater supply, the cooler's own compressor, the pumps and the logger chassis are catalogue items, bought in, not invented. What Neometrix engineers is the facility around them: the cryostat, the shield and the supports, the gas and vacuum system, the tilt stage, the force platform mounting and the proof. So the honest position is that the facility is engineered to order, the neighbouring disciplines are in the building, and the first facility of this exact kind will be built around the customer's own duty rather than taken off a shelf.
    Q · 07 Which standard applies, and what can the facility not do?
    No test standard is quoted on this page. Cooler makers publish their own test conditions, and the customer states the conditions the facility is to reproduce: the cold temperatures, the heat loads, the angles and the length of the runs. The facility makes a cooler's behaviour visible and records it. It does not certify a cooler, it is not a thermal vacuum chamber and not a helium charging station, and it does not replace the operator's own judgement about who is near a charged line and when. This page claims no certification or accreditation. No temperature, power, force, time or pressure figure is printed here, and approval of a cooler rests with the customer and the authority they name; none is claimed here.
    Q · 08 What do you need from us to quote?
    Six things, and most of them describe your work rather than the facility. First, the cooler: which one or which kinds, and how it is mounted. Second, the curve: the cold temperatures and the heat loads that matter. Third, the extras: whether the force into the mount, the tilt and a long run are wanted. Fourth, the gas: the working gas, and what may be vented. Fifth, the room: what services it has, how much space there is and where the compressor can go. Sixth, the record: whether a proving run and a test record are needed. From that we come back with a facility concept, a proving plan you can check, and a budgetary price.
    09
    Related

    The neighbouring pages, and how they differ from this one.

    Three neighbours: one holds a whole unit under vacuum, one decants and recharges helium, one stores and supplies liquids and gas.

    Browse all Neometrix product lines.

    Get a quotation

    Tell us the cooler,
    and the curve you need.

    The projects desk replies within two working days with a facility concept, a proving plan you can check, and a budgetary quotation. Write to [email protected] or use the form.

    Enquire — cryocooler test facility Capability sheet (PDF) +91 7777 876 876
    ISO 9001 / 14001 ENGINEERED-TO-ORDER CLASS — CRYOCOOLER TEST FACILITY DUTY · CRYOSTAT AND SHIELD · HEATER AND SENSORS · HELIUM AND VACUUM · FORCE AND TILT · BUILD · PROVE — A CRYOCOOLER'S COOLING POWER IS A CURVE, NOT A NUMBER. ENGINEERED IN NOIDA · INDIA

    Trending Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat
    move to top arrow