200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Neometrix / Rescue and Line-Handling Equipment / Pneumatic Line Thrower / NMX-PLT-105
    NMX-PLT-105 · ENGINEERED-TO-ORDER CLASS — DUTY · RESERVOIR AND VALVE · TUBE AND HEAD · LINE AND CONTAINER · BUILD · PROVE

    Pneumatic Line Thrower. The line sets the range.

    A pneumatic line thrower carries a light line across a gap that a person cannot cross: a river, a ravine, the space between a quay and a vessel, a beam out of reach. Stored air drives a thrown head out of a tube, and the head pulls the line out behind it from its own container. Neometrix engineers it as a system: the reservoir, the valve, the tube, the head, the line and the proof.

    So the thrower has to know that the line sets the range, let the line out in order, without a snarl, and keep every charge inside what the reservoir and its relief valve can hold.

    A stand-mounted pneumatic line thrower on a plain white studio background: a bright aluminium air reservoir in two steel cradles on a small steel tripod, a black quick-release valve with a lever, a long stainless steel throw tube pointing up and to the left with a soft round orange rubber head in its mouth, a thin white line running from the head down to a round pale grey line container with the line coiled inside, and no people
    Fig · 01 — A stand-mounted pneumatic line thrower: an air reservoir on a tripod, a quick-release valve, a long throw tube with a soft head in its mouth, and the line running down to its container — illustrative render.
    The air
    gives the head its speedmore air buys less and less distance
    The line
    sets the rangeits weight, its thickness and how it leaves the container
    The head
    carries the line outsoft and weighted, or fitted with a hook
    The reservoir
    holds and lets gowith a relief valve set below its rating
    Status
    engineered to orderno delivery is claimed
    ISO 9001ISO 14001IMO LSA Code reference for line-throwing appliances
    01
    Overview

    What a line thrower has to get right, and what goes wrong when it does not.

    Because the air is the easy part, and the line is the part that decides.

    Three thrown heads and a line container on a plain white studio background: a small round orange rubber head, a larger dark grey teardrop-shaped rubber head and a small steel hook head, each with a loop of thin white line through a steel ring, and in front a round pale grey line container with the thin white line coiled in layers and its free end rising from the centre, and no people
    Fig · 02 — Three thrown heads, a soft round one, a heavier teardrop-shaped one and a small hook head, each with its line, and a line container with the line laid in layers — illustrative render.

    The line sets the range.

    What the thrower is for

    It carries a light line across a gap, so that a heavier rope can be hauled over after it: across a river or a ravine, from a quay to a vessel, over a beam or a branch that no one can reach. It gets the first line across, and nothing more.

    Why the line sets the range

    The air gives the head its speed. But the head drags the line out behind it, and every metre that comes out adds weight and air drag. Drag grows with the square of the speed, so beyond a point more air buys very little more distance. A lighter, thinner line goes farther, and a heavy line stops the head short whatever the air.

    Why the line must leave its container in order

    The line comes out of the container in the order it went in, with nothing to snag it. A snarl or a knot in the first part of the line stops the head, and the throw is lost however much air is behind it.

    How the air is stored and let go

    The air is stored in a reservoir, which is a pressure vessel. A quick-release valve lets it go all at once into the throw tube behind the head. A slow valve wastes the air, and a fast one gives the head its speed.

    Why the reservoir has its own relief valve

    Whatever fills the reservoir, a hand pump, a cylinder or a compressor, must not be able to fill it past its rating. A relief valve set below the rating of the reservoir lets the excess go.

    What the head is

    The head is soft and weighted. It carries the line out, so it must be heavy enough to pull the line it drags, and soft enough not to harm what it lands on. A hook head is fitted when the line has to catch on the far side.

    Why a person is never in the path

    A thrown head is moving fast at the start. The thrower is never pointed at a person, the landing area is kept clear, and the reservoir is emptied before the thrower is put away.

    Why a thrower is not for every job

    It carries a first light line, and no load. It is not a replacement for the rope that follows. The duty states how wide the gap is, what the head must land on and what is on the far side, and the thrower is built for that.

    02
    The method

    Duty, reservoir and valve, tube and head, line and container, build and prove.

    Six steps in a fixed order. The line and its container are the two that a quick job skips.

    1 · Duty

    The gap, the landing area, the wind, the line that follows and the person who will use the thrower are noted, with the place where it is kept.

    2 · Reservoir and valve

    The reservoir, its relief valve and the quick-release valve are matched to the head and the line. The reservoir is built as a pressure vessel with a margin.

    3 · Tube and head

    The tube and the head are matched, so that the head seats the same way every time, and the line is joined to it by a joint stronger than the line.

    4 · Line and container

    The line and its container are chosen together, so that the line leaves in order, and the lightest line that will do the work is picked.

    5 · Build

    The reservoir, the valves, the tube and the container are built and fitted, and the seals, the safety catch and the relief valve are checked.

    6 · Prove

    A pressure test, a relief valve check and repeated proving throws over open ground with a clear landing area are run, and the record goes with the thrower.

    Which fault, which safeguard

    What can go wrongWhy it happensWhat the thrower does about it
    The head falls shortthe line is too heavy or too thick, or it drags in the containera lighter line, a head matched to it, and a container that lets the line out freely
    More air does not helpthe drag grows with the square of the speed, so each gain in air buys less distancethe line chosen first, then the reservoir and the valve sized to the head and that line
    The line snarls or knotsit left the container out of order, or caught on somethinga container in which the line lies in layers, with nothing in its path, and a proving throw with the container in place
    The line parts at the headthe joint is weaker than the line, or the load is taken at one pointa joint stronger than the line, tried at the build
    The head veers off the line of throwa side wind, or a head that seats unevenly in the tubea straight smooth tube, a balanced head, and a note of the wind in the manual
    The reservoir is overfilledthe source of air is stronger than the reservoir's ratinga relief valve set below the rating, and a charging connection that fits only the right source
    The release is slow or sticksa seal is worn or dirtya quick-release valve checked at the build and inspected in service
    Someone is in the paththe throw is released with people near the landing areaa safety catch, a clear landing area, and a procedure that says the thrower is never pointed at a person

    The step people underrate is the line. A thrower looks the same whether its line pays out cleanly or snarls in the first part of the throw.

    03
    Work content

    What the thrower contains, element by element.

    Read it as a checklist: a thrower missing a row will throw a head, but it will not tell you how far the line will go.

    The air end of a stand-mounted pneumatic line thrower on a plain white studio background: a bright aluminium cylindrical air reservoir in a steel cradle, a black quick-release valve with a lever at the front joined to the start of a steel throw tube, a small brass spring relief valve on top, a brass charging connection with a black cap joined by a black hose to a small black hand pump standing beside it, and no people
    Fig · 03 — The air end of the thrower: the reservoir in its cradle, the quick-release valve and its lever, a relief valve on top, and a charging connection with a hand pump — illustrative render.
    ElementWhat it doesWhat matters
    Air reservoirstores the aira pressure vessel with a margin, a relief valve set below its rating, and a charging connection
    Quick-release valvelets the air go at oncea valve that opens fast and seals well, checked at the build and inspected in service
    Throw tubeguides the heada straight, smooth tube in which the head seats the same way every time
    Headcarries the line outa soft, weighted head joined to the line by a joint stronger than the line, with a hook head as an option
    Lineis thrownthe lightest line that does the work, easy to see, with a breaking strength that suits the rope that follows
    Line containerpays the line outa container in which the line lies in layers and leaves in order, with nothing to snag it
    Charging connectionfills the reservoira connection for a hand pump, a cylinder or a compressor, that fits only the right source
    Safety catchkeeps the air in until it is wanteda catch that holds the valve shut, and a release that needs a deliberate action
    Grip or standholds the throwera grip for a hand-held thrower and a stand for a mounted one, so that the throw leaves in the direction chosen
    Caseprotects the seta case that carries the thrower, the heads and the lines, and keeps them dry and clean
    Testing & documentationprove the thrower firsta pressure test of the reservoir, a check of the relief valve, repeated proving throws, and a record the customer can inspect

    The elements that decide the result are the line and the line container. The first sets how far the head can carry it, and the second lets it go.

    Full specification — expand
    SystemAn air reservoir with a relief valve and a charging connection; a quick-release valve; a throw tube; a soft, weighted head, or a hook head; a line and a line container that pays it out in order; a grip or a stand, and a case; and a pressure test, a relief valve check and repeated proving throws, with documentation, before handover
    The One IdeaThe line sets the range.
    Why The Line Sets The RangeThe air gives the head its speed, but the head drags the line out behind it, and every metre of line out adds weight and air drag that grows with the square of the speed, so more air buys less and less distance; a lighter, thinner line goes farther, and a line that leaves its container in order goes farther still
    Why The Reservoir Has Its Own Relief ValveWhatever fills the reservoir, a hand pump, a cylinder or a compressor, must not be able to fill it past its rating, so a relief valve set below the rating of the reservoir lets the excess go
    StandardsThe IMO LSA Code, chapter VII, covers line-throwing appliances. This page prints none of its requirements, and no edition year. Approval of a thrower rests with the customer and the authority they name; none is claimed here
    ConfigurationsA hand-held thrower, a stand-mounted thrower, and a special thrower
    Scope BoundaryThis page is the pneumatic line thrower, which carries a first light line across a gap. It is not a replenishment at sea system, which passes stores and fuel between two vessels once a line is across (see replenishment-at-sea and fuelling-at-sea system), not a rescue tool power unit, which drives the cutters and spreaders of a rescue team (see hydraulic rescue tool power unit) and not a relief valve test bench, which proves relief valves (see safety and relief valve test bench). It does not carry a load, and it does not replace the operator's own judgement. No certification or accreditation is claimed here
    StatusNeometrix engineers pneumatic line throwers to order, and no delivered pneumatic line thrower is claimed.
    04
    Configurations

    One method, three ways to build the thrower.

    The method, the line and the container are shared. What changes is who holds the thrower, how far the head must go, and what fills the reservoir.

    Hand-held thrower

    A grip, a short tube and a small reservoir

    For one person, from a bank, a quay or a roof: a small reservoir filled from a hand pump or a cylinder, and a light line in a container that clips on.

    Stand-mounted thrower

    A stand, a longer tube and a larger reservoir

    For a fixed post or a mounted base: a longer tube and a larger reservoir, filled from a compressor or a cylinder, for a heavier head and a longer throw.

    Special thrower

    A head, a line or a source of air that is not standard

    For a duty that does not fit: a hook head, a line of another kind, or a different source of air, chosen with the customer, with the same line container and the same proof.

    And the part that is not equipment at all, yet decides all three: what the line must carry after the throw. It is taken from the customer's own work, not from the thrower.

    05
    The drawings

    A reference set, drawn as real CAD sheets.

    Two sheets of one reference configuration: the arrangement of a stand-mounted pneumatic line thrower with three details, and its air circuit and the curve of range against air. They show the reservoir and its valves, the tube and the head, the line and its container, and why more air buys less and less distance. They carry tags and letters only. Every distance, pressure, mass and size is fixed by design for the customer's duty.

    Reference drawing sheet one, the arrangement and details of a stand-mounted pneumatic line thrower. A side elevation shows an air reservoir lying in two cradles on a tripod stand, a quick-release valve with a lever and a safety catch at the front, a relief valve on top, a charging connection at the rear, a throw tube with a soft head in its mouth, and the line, drawn dashed, running from the head down to its container, with the length of the tube and the spread of the legs marked by letters. Detail A shows a soft head and a hook head, each joined to its line. Detail B shows the quick-release valve in section, closed and open. Detail C shows the line container in section, with the line laid in layers and leaving from the centre. An item list numbers ten parts. A title block stamped reference configuration, not for construction
    Fig · 04 — Sheet 01, the arrangement: the thrower in elevation, the two kinds of head, the quick-release valve closed and open, and the line container. Reference configuration, letters only.
    Reference drawing sheet two, the air circuit and the curve of a stand-mounted pneumatic line thrower. An air circuit shows a source feeding a reservoir through a check valve, with a relief valve and a vent valve on the reservoir, a quick-release valve with its safety catch, a throw tube with the head at its mouth, and the line, dashed, leaving its container. Detail A is a computed curve of range against the air for a light line and a heavy line: two equal steps of air buy a large gain early and a small gain late, and the heavy line sets a lower ceiling. A table of what each step does, and a title block stamped reference configuration, not for construction
    Fig · 05 — Sheet 02, the air circuit and the curve: the reservoir and its valves, and the range against the air for a light and a heavy line. Reference configuration, tags only.

    Every real thrower is drawn for its own duty, its own head and line and its own source of air. These sheets are the arrangement and the order of working that a project set starts from. Approval of any drawing rests with the customer and the authority they name; none is claimed here.

    06
    Where it is used

    Wherever a light line has to cross a gap first, and a heavier rope has to follow it.

    The common thread is a gap that people cannot cross, a rope that has to get across, and a line that has to go farther than an arm can throw it.

    Rescue teams

    Where a person in the water or on a ledge has to be reached with a line that can be thrown farther than by hand.

    Crossing teams

    Where a first light line must go across a river or a ravine, so that a heavier rope can be hauled over and a crossing set up.

    Port crews

    Where a light line is passed from a quay to a vessel, or from one vessel to another, so that a heavier line can be hauled across.

    Structure crews

    Where a line has to go over a beam, a branch or a cross-arm that no one can reach, so that a rope or a cable can be pulled after it.

    07
    Watch

    See it in motion.

    A short walkthrough video of the Pneumatic Line Thrower.

    08
    FAQ

    Common questions.

    Longer answers, for readers who want the reasoning.

    Q · 01 What does a pneumatic line thrower actually do?
    It carries a light line across a gap that a person cannot cross, so that a heavier rope can be hauled over after it. Air is stored in a reservoir. A quick-release valve lets it go into a throw tube, and it drives a soft, weighted head out of the tube. The head drags the line out behind it from a container that pays it out in order. A hand-held thrower serves one person, and a stand-mounted thrower serves a fixed post. The thrower does not decide where the line is needed or what follows it. That comes from the customer's own work, and the thrower is built, proved and recorded to carry it out.
    Q · 02 Why does the line set the range?
    Because the head has to drag the line out behind it. The air gives the head its speed at the start, but every metre of line that comes out adds weight, and the line in the air adds drag that grows with the square of the speed. Past a point, more air buys very little more distance, and a heavier or thicker line shortens the throw whatever the air. So the line is chosen first, as light and as thin as the job allows, and the reservoir and the valve are then sized for the head and that line. A longer throw usually asks for a lighter line, and not only for more air.
    Q · 03 Why a quick-release valve, and why a relief valve on the reservoir?
    Because the air is only useful if it is let go at once. A quick-release valve opens fast and gives the head its speed in one short push, and a slow valve lets the air leak past the head. And because the reservoir is a pressure vessel, whatever fills it, a hand pump, a cylinder or a compressor, must not be able to fill it past its rating. A relief valve set below that rating lets the excess go. The valve and the relief valve are checked at the build, and the relief valve is checked again in service.
    Q · 04 Why does the line container matter as much as the air?
    Because a snarl in the first part of the line stops the head, however much air is behind it. The line lies in the container in layers and leaves in the order it went in, with nothing to catch it. It is laid in by a method, and not by hand, and the throw is proved with the container in its place. A container that pays out cleanly lets a lighter line be used, and a lighter line goes farther. This is the step a quick job skips, and it is the one that most often explains a short throw.
    Q · 05 Is this the same as a replenishment at sea system, a rescue tool power unit or a relief valve test bench?
    No, and the differences are worth stating precisely. The replenishment-at-sea and fuelling-at-sea system page covers passing stores and fuel between two vessels once a line is across. The hydraulic rescue tool power unit page covers driving the cutters and spreaders of a rescue team. The safety and relief valve test bench page covers proving relief valves. This page is the thrower that carries the first light line across a gap. It does not replace any of them, and it does not claim what they claim a second time.
    Q · 06 Has Neometrix built one of these?
    We would rather answer this plainly than let a page imply otherwise. Neometrix engineers pneumatic line throwers to order, and no delivered pneumatic line thrower is claimed. What stands behind the offer is adjacent: Neometrix engineers a replenishment-at-sea and fuelling-at-sea system (see the replenishment-at-sea and fuelling-at-sea system page), a hydraulic rescue tool power unit (see the hydraulic rescue tool power unit page) and a safety and relief valve test bench (see the safety and relief valve test bench page). The reservoir, the valves, the tube, the line and the seals are catalogue items, bought in, not invented. What Neometrix engineers is the thrower around them: the matching of reservoir, valve, tube, head and line, the line container, the protection and the proof. So the honest position is that the thrower is engineered to order, the neighbouring disciplines are in the building, and the first thrower of this exact kind will be built around the customer's own duty rather than taken off a shelf.
    Q · 07 Which standard applies, and what can the thrower not do?
    The IMO LSA Code, chapter VII, covers line-throwing appliances. This page prints none of its requirements, and no edition year: those come from the standard the customer names. The thrower carries a first light line across a gap. It does not carry a load, it is not a substitute for the rope that follows, and it does not replace the operator's own judgement about the landing area and who is near it. It is never pointed at a person. This page claims no certification or accreditation. No distance, pressure, mass or time figure is printed here, and approval of a thrower rests with the customer and the authority they name; none is claimed here.
    Q · 08 What do you need from us to quote?
    Six things, and most of them describe your duty rather than the thrower. First, the gap: how wide it is, and what is on the far side. Second, the landing area: what the head must reach, and what it must not hit. Third, the line: what follows it, and how strong it must be. Fourth, the user: one person or a fixed post, and in what weather. Fifth, the air: what will fill the reservoir. Sixth, the record: whether proving throws and a test record are needed. From that we come back with a thrower concept, a proving plan you can check, and a budgetary price.
    09
    Related

    The neighbouring pages, and how they differ from this one.

    Three neighbours: one passes loads between vessels, one drives rescue tools, one proves relief valves.

    Browse all Neometrix product lines.

    Get a quotation

    Tell us the gap,
    and the line that must follow.

    The projects desk replies within two working days with a thrower concept, a proving plan you can check, and a budgetary quotation. Write to [email protected] or use the form.

    Enquire — line thrower Capability sheet (PDF) +91 7777 876 876
    ISO 9001 / 14001 ENGINEERED-TO-ORDER CLASS — PNEUMATIC LINE THROWER DUTY · RESERVOIR AND VALVE · TUBE AND HEAD · LINE AND CONTAINER · BUILD · PROVE — THE LINE SETS THE RANGE. ENGINEERED IN NOIDA · INDIA

    Trending Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat
    move to top arrow