200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Neometrix / Gas Dynamics Test Facilities / Shock Tube Test Facility / NMX-SHT-110
    NMX-SHT-110 · ENGINEERED-TO-ORDER CLASS — DUTY · TUBE AND DIAPHRAGM · GAS AND VACUUM · RELEASE · SENSORS AND TIMING · BUILD · PROVE

    Shock Tube Test Facility. A step you can calculate.

    A shock tube is a long tube with a driver at a high pressure at one end, a driven section at a low pressure at the other, and a thin diaphragm between them. When the diaphragm opens, a shock wave runs down the driven section, and the pressure behind it is a step. Neometrix engineers the facility as a whole: the tube, the diaphragm station, the gas and vacuum system, the release and the sensors.

    So the facility has to know that a shock tube makes a pressure step you can calculate, open the diaphragm evenly, and time the shock between known points.

    A shock tube test facility on a plain white studio background: a long straight bright steel tube on two pale grey steel stands, a short thicker pale grey driver section at the left with a small valve on top, a pair of bolted flanges joining it to a long bright steel driven section, four small sensors screwed into the side of the driven section with thin black cables hanging down, a flanged end at the right with a small sensor in its centre, a pale grey gas cylinder with a braided hose at the left, a black vacuum pump with a braided hose at the right, and no people
    Fig · 01 — A shock tube facility: a short driver at the left, a diaphragm station between two bolted flanges, a long driven section with four sensors in its side, and a flanged end with one more sensor — illustrative render.
    The diaphragm
    is scoredso that it opens evenly
    The shock
    runs the driven tubeand reflects from the end wall
    The step
    is calculatedfrom the speed of the shock
    The test time
    is set by the driverits length decides how long
    Status
    engineered to orderno delivery is claimed
    ISO 9001ISO 14001ISA-37.16.01 reference for the dynamic calibration of pressure transducers
    01
    Overview

    What a shock tube has to get right, and what goes wrong when it does not.

    Because the step is over in an instant, the diaphragm, the gases and the timing all have to be right, and a fault shows up as a step that is not the step the calculation promised.

    The diaphragm station of a shock tube on a plain white studio background: two large bright steel flanges clamped face to face with a ring of bolts, and in front of them two thin round aluminium discs, one flat and marked with a plain cross-shaped score, and one opened outward into curled petals around a round hole, and no people
    Fig · 02 — The diaphragm station: two bolted flanges, a flat scored diaphragm and one that has opened in petals — illustrative render.

    A shock tube makes a pressure step you can calculate.

    What the facility is for

    It makes a very fast and very clean step in pressure, and a short run of fast gas flow behind it, so that a sensor, a material or a gas can be tested against them.

    How the shock is made

    The driver holds gas at a high pressure and the driven section holds gas at a low one. When the diaphragm opens, a shock wave runs into the low-pressure gas, and an expansion wave runs back into the driver.

    Why the step can be calculated

    The speed of the shock fixes the jump in pressure, temperature and density across it, by the ordinary gas laws. The speed is timed between sensors a known distance apart, so the step comes from the calculation and not from the sensor under test.

    Why the end wall matters

    The shock reflects from the closed end and runs back, raising the pressure again in the gas it passes. A sensor in the end wall sees the first step and then the larger step of the reflection.

    Why the diaphragm decides

    A diaphragm does not open in an instant. If it tears unevenly, the shock forms late and weak, and pieces of it can fly down the tube. So it is scored, to open in petals, evenly and the same way every time.

    Why the driver sets the test time

    Behind the shock there is a short time of steady gas before the waves from the far ends of the tube arrive. A longer driver gives a longer time. The tube is sized for the time the duty needs.

    Why the gases are chosen

    A light gas such as helium in the driver makes a stronger shock than a heavy one. The driven gas is air, or whatever gas the work needs. The tube is evacuated and filled in a set order, so that the gases are what the calculation assumes.

    Why a shock tube is not for every job

    It is not a mechanical shock machine, which hits a part to test its structure. It is not a wind tunnel, which runs a steady stream for a long time. It makes one event, calculated and repeated.

    02
    The method

    Duty, tube and diaphragm, gas and vacuum, release, sensors, build and prove.

    Six steps in a fixed order. The diaphragm and the filling order are the two that a quick job skips.

    1 · Duty

    The sensors, the materials or the gases to be tested, the step and the test time wanted, the room and the services, and what is recorded, are noted.

    2 · Tube and diaphragm

    The tube is made straight, smooth and sealed, and the diaphragm station holds a diaphragm that is scored so that it opens evenly.

    3 · Gas and vacuum

    The driver gas, the driven gas and the vacuum are brought to their set levels in a set order, with a purge between shots.

    4 · Release

    The diaphragm is opened on command, behind guards, with a vent path and a catch for fragments, and the release works apart from the controller.

    5 · Sensors and timing

    Side-wall sensors at known distances time the shock, an end-wall sensor takes the step, and a fast acquisition chassis records all of them.

    6 · Build and prove

    The tube is built and leak tested, low-pressure shots come first, the measured shock speed is compared with the calculation, every interlock is tried, and the record goes with the facility.

    Which fault, which safeguard

    What can go wrongWhy it happensWhat the facility does about it
    The shock is weak or latethe diaphragm opens slowly or unevenlya scored diaphragm of the right material and thickness, held flat in a station that seals it
    Fragments fly down the tubethe diaphragm tears off pieces instead of opening in petalsscoring that opens it in petals, a catch for fragments, and a tube kept clean
    The step is not the step calculatedthe gases were not what the calculation assumed, for example air left in the driver, or a leakevacuation and filling in a set order, a leak check, and the gases logged with every shot
    The shock speed is wrongthe sensors are not where they were thought to be, or the timing is outa measured spacing, a fast timing unit, and a record of every arrival
    The test time is too shortthe driver is too short, so the waves from the far end arrive earlya driver sized for the time, and a driven section long enough for the shock to settle
    The step has a ring on itthe sensor or its mounting resonates, or the bore is roughsensors mounted flush, a smooth bore, and the response compared with the calculated step
    The shots do not repeatthe diaphragm or the filling varies from shot to shotthe same diaphragm, the same scoring and the same filling order every time, and a count of shots
    Someone is near a charged tubethe tube is filled while people are in the roomguards, interlocks, a control room outside, and a procedure that says nobody stands near a charged tube

    The step people underrate is the filling order. A tube looks the same whether the driver was evacuated before it was filled or not, and only one of them gives the step that was calculated.

    03
    Work content

    What the facility contains, element by element.

    Read it as a checklist: a facility missing a row will make a shock, but it will not make a step that can be calculated and repeated.

    The end of the driven section of a shock tube on a plain white studio background: a bright steel tube on a pale grey steel stand ending in a flanged end wall with a ring of bolts and a small sensor in its centre, three small sensors screwed into the side of the tube in a row with thin black cables hanging down, and no people
    Fig · 03 — The end of the driven section: three sensors in the side wall and one in the centre of the end wall — illustrative render.
    ElementWhat it doesWhat matters
    Driver sectionholds the high-pressure gasa section sized for the pressure and for the test time wanted, with a fill line and a vent
    Driven sectioncarries the shocka long, straight tube with a smooth bore, so that the shock settles and the sensors see it clean
    Diaphragm stationholds the diaphragmtwo flanges that clamp the diaphragm flat and seal it, and open to change it quickly
    Diaphragm and openingstart the shocka scored diaphragm that opens in petals, opened by pressure or by a cutter, the same way every shot
    Driver gas systemfills the drivera supply of a light gas through a regulator and a valve, with a relief valve and a vent path
    Driven gas and vacuum systemsets the low-pressure gasa vacuum pump, a fill line for the driven gas and a purge, so that the gas is what the calculation assumes
    Vent and fragment catchtake the gas and the piecesa vent path that leads away from people, and a catch that holds the petals of the diaphragm
    Sensor portshold the sensorsports in the side wall at known distances, and one in the end wall, with sensors mounted flush
    Timing and acquisitiontime the shock and record the steptiming units and a fast chassis that record every arrival and the whole step, with a log of every shot
    End wall or test sectionends the tubea closed end for the reflected shock, or a nozzle and a test section for a short run of fast flow
    Controller and safetyrun the shota fill and release sequence, guards and interlocks, and a release that works apart from the controller
    Testing & documentationprove the facility firsta leak test, low-pressure shots, the shock speed compared with the calculation, every interlock tried, and a record the customer can inspect

    The elements that decide the result are the diaphragm station and the timing. The first makes the shock the same every time, and the second gives the speed from which the step is calculated.

    Full specification — expand
    SystemA driver section and a long driven section joined at a diaphragm station; a scored diaphragm and an opening mechanism; a driver gas system, a driven gas system and a vacuum system with a set filling order; a vent path and a catch for fragments; side-wall sensor ports and an end-wall sensor port; timing units and a fast acquisition chassis; an end wall or a test section; supports that keep the tube straight; a controller, guards and interlocks; and a proving run, an interlock check and documentation before handover
    The One IdeaA shock tube makes a pressure step you can calculate.
    Why The Step Can Be CalculatedThe speed of the shock fixes the jump in pressure, temperature and density across it by the ordinary gas laws, and the speed is timed between side-wall sensors a known distance apart, so the step is worked out from the calculation and not from the sensor under test
    Why The Diaphragm DecidesA diaphragm does not open in an instant. If it tears unevenly the shock forms late and weak and pieces can fly down the tube, so it is scored to open in petals, evenly and the same way every time
    StandardsISA-37.16.01 is a guide to the dynamic calibration of pressure transducers, with a section on shock tubes. This page prints none of its requirements, and no edition year. Approval of a sensor rests with the customer and the authority they name; none is claimed here
    ConfigurationsA calibration shock tube, a research shock tube, and a shock tube with a test section
    Scope BoundaryThis page is the shock tube test facility, which makes one shock and calculates it. It is not a mechanical shock machine, which hits a part to test its structure (see shock qualification and shock test machines), not a wind tunnel, which runs a steady stream past two instruments (see calibration wind tunnel) and not a pressure regulation system, which holds the supply pressure of a blowdown tunnel (see wind tunnel pressure regulation system). It does not certify a sensor, and it does not replace the operator's own judgement. No certification or accreditation is claimed here
    StatusNeometrix engineers shock tube test facilities to order, and no delivered shock tube test facility is claimed.
    04
    Configurations

    One method, three ways to build the facility.

    The method, the diaphragm and the filling order are shared. What changes is how long the tube is, what sits in the end of it, and what is measured.

    Calibration shock tube

    A clean step for a sensor

    For testing the response of pressure sensors: a compact tube with a sensor port in the end wall, a row of side-wall sensors that time the shock, and a step that is calculated from the speed.

    Research shock tube

    A long tube with ports and windows

    For studying hot gases and shock waves: a longer driven section with extra ports, a window for the optics, a sampling port, and a driver long enough for the test time the work needs.

    Shock tube with a test section

    A short run of fast flow

    For a short run of fast gas flow: the end of the tube opens through a nozzle into a test section, where a model or a probe sits in the flow for the time the driver allows.

    And the part that is not equipment at all, yet decides all three: the gas law. The step is worked out from the shock speed by the customer's own method, not from the facility.

    05
    The drawings

    A reference set, drawn as real CAD sheets.

    Two sheets of one reference configuration: the arrangement of a shock tube with three details, and its gas, release and timing circuits with the curves that show why a shock tube makes a pressure step you can calculate. They show the tube, the diaphragm and the sensors, and how the step follows from the speed of the shock. They carry tags and letters only. Every pressure, speed, time and length is fixed by design for the customer's duty.

    Reference drawing sheet one, the arrangement and details of a shock tube test facility. An elevation shows a calibration shock tube inside its guard: a driver filled from a gas cylinder through a regulator and a valve, with a relief valve and a transducer; a diaphragm station between two flanges with a cutter under it; a long driven section with a fragment catch, four side-wall sensors and one end-wall sensor; a vacuum pump with its valve, a driven gas inlet and a second transducer; and, outside the guard, a control room with a controller and a timing and acquisition unit, with the cables and the release signal drawn in. Letters mark the lengths of the driver and the driven section and the spacing of the sensors. Detail A shows the diaphragm station in section. Detail B shows a sensor mounted flush with the bore. Detail C shows a scored diaphragm before and after it opens in petals. An item list numbers nine parts. A title block stamped reference configuration, not for construction
    Fig · 04 — Sheet 01, the arrangement: the shock tube in its guard, the diaphragm station, the sensor port and the scored diaphragm. Reference configuration, letters only.
    Reference drawing sheet two, the gas, release and timing circuits and the curves of a shock tube test facility. A circuit shows a gas cylinder feeding the driver through a regulator and a valve, a relief valve and a transducer on the driver, the diaphragm, a cutter, a driven section with four sensors and an end-wall sensor, a vacuum pump with its valve, a driven gas inlet and a second transducer, and a door interlock feeding a release of its own that operates the cutter; a timing chain runs from the sensors through a conditioner, a timing unit and an acquisition to the computation of the step. Detail A is a computed wave diagram of distance along the tube against time: the shock, the contact surface, the reflected shock, the expansion wave and the test time at a station. Detail B is a computed plot of the pressure seen by a side-wall sensor, two steps, and by an end-wall sensor, one larger step. Detail C is a computed plot of the step against the shock speed. A title block stamped reference configuration, not for construction
    Fig · 05 — Sheet 02, the circuits and the curves: the wave diagram, the pressure traces and the step against the shock speed. Reference configuration, tags only.

    Every real facility is drawn for its own duty, its own gases and its own room. These sheets are the arrangement and the order of working that a project set starts from. Approval of any drawing rests with the customer and the authority they name; none is claimed here.

    06
    Where it is used

    Wherever a pressure has to change faster than a valve can, and the change has to be known.

    The common thread is a sensor, a material or a gas that has to meet a very fast event, and a step whose height has to be known and not guessed.

    Calibration laboratories

    Where the dynamic response of pressure sensors is tested against a step that can be calculated.

    Instrument makers

    Where a new sensor has to be shown to follow a very fast change before it is sold.

    Research laboratories

    Where hot gases, shock waves and the behaviour of a gas behind a shock are studied.

    Gas dynamics groups

    Where a short run of fast flow over a model or a probe is needed, without a large tunnel.

    07
    Watch

    See it in motion.

    A short walkthrough video of the shock tube test facility.

    08
    FAQ

    Common questions.

    Longer answers, for readers who want the reasoning.

    Q · 01 What does a shock tube facility actually do?
    It makes one very fast event and measures it. A driver at a high pressure and a long driven section at a low pressure are separated by a scored diaphragm. The tube is evacuated and filled in a set order, and then the diaphragm is opened on command. A shock wave runs down the driven section, side-wall sensors a known distance apart time it, and a sensor in the end wall records the step in pressure as the shock arrives and again as it reflects. A fast chassis records everything. The facility does not choose the test. That comes from the customer's own duty, and the facility is built, proved and recorded to carry it out.
    Q · 02 Why can the step be calculated?
    Because a shock is a very thin front across which the gas obeys the ordinary conservation laws, and those laws tie the jump in pressure, temperature and density to the speed of the shock. So if the speed is known, the step is known. The speed is the easy part to measure: two sensors in the side wall, a known distance apart, give the time the shock takes to pass between them. The step that follows from that speed is then compared with what the sensor under test reported. The sensor is judged against the calculation, which is why the calculation has to be trusted, and why the spacing and the timing are checked before anything else.
    Q · 03 Why is the diaphragm so important?
    Because the whole event starts there. An ideal diaphragm would vanish in an instant, and no real one does: it opens over a short time, and how it opens changes how fast the shock forms and how strong it is. A diaphragm that tears unevenly gives a late and weak shock, and it can send pieces down the tube that spoil the flow and the sensors. So the diaphragm is scored, usually in a cross, to a controlled depth, so that it opens in petals that fold back against the wall. The same material, thickness and scoring are used for every shot, and the station is built so that the diaphragm is changed quickly and clamped flat each time.
    Q · 04 What sets the test time?
    The length of the tube. Behind the shock there is a short time during which the gas is steady, and it ends when a wave from one of the far ends of the tube arrives. The expansion wave that ran back into the driver reflects from the closed end of the driver and runs forward again, so a longer driver delays its arrival and gives a longer time. The choice of the driver gas matters as well, because a light gas such as helium sends that wave back early. So the duty states the time wanted, and the tube is sized for it. Nothing here prints a length or a time: those come from the customer's duty at design review.
    Q · 05 Is this the same as a mechanical shock machine, a wind tunnel or a pressure regulation system?
    No, and the differences are worth stating precisely. The shock qualification and shock test machines page covers machines that hit a part to test its structure, which is a different kind of shock altogether. The calibration wind tunnel page covers a steady stream past two instruments. The wind tunnel pressure regulation system page covers holding the supply pressure of a blowdown tunnel. This page is the facility that makes one shock in a tube and calculates it. It does not replace any of them, and it does not claim what they claim a second time.
    Q · 06 Has Neometrix built one of these?
    We would rather answer this plainly than let a page imply otherwise. Neometrix engineers shock tube test facilities to order, and no delivered shock tube test facility is claimed. What stands behind the offer is adjacent: Neometrix engineers a wind tunnel pressure regulation system (see the wind tunnel pressure regulation system page), a calibration wind tunnel (see the calibration wind tunnel page) and shock qualification and shock test machines (see the shock qualification and shock test machines page). The fast pressure sensors, the timing units and the acquisition chassis are catalogue items, bought in, not invented. What Neometrix engineers is the facility around them: the tube, the diaphragm station, the gas and vacuum system, the release and the proof. So the honest position is that the facility is engineered to order, the neighbouring disciplines are in the building, and the first facility of this exact kind will be built around the customer's own duty rather than taken off a shelf.
    Q · 07 Which standard applies, and what can the facility not do?
    ISA-37.16.01 is a guide to the dynamic calibration of pressure transducers, with a section on shock tubes. This page prints none of its requirements, and no edition year: those come from the guide and the authority the customer names. The facility makes a shock, times it and records what the sensors saw. It does not certify a sensor, it is not a mechanical shock machine and not a wind tunnel, and it does not replace the operator's own judgement about who is near a charged tube and when. This page claims no certification or accreditation. No pressure, speed, time, length or temperature figure is printed here, and approval of a sensor rests with the customer and the authority they name; none is claimed here.
    Q · 08 What do you need from us to quote?
    Six things, and most of them describe your work rather than the facility. First, the duty: what is tested, whether a sensor, a material or a gas. Second, the step: the size of the step wanted and the range of the sensors under test. Third, the test time: how long the steady gas has to last. Fourth, the gases: the driver gas and the driven gas, and what may be vented. Fifth, the room: what services it has, how long a tube it can hold, and where the vent can go. Sixth, the record: whether a proving run and a test record are needed. From that we come back with a facility concept, a proving plan you can check, and a budgetary price.
    09
    Related

    The neighbouring pages, and how they differ from this one.

    Three neighbours: one is a mechanical shock machine, one runs a steady stream, one holds the supply pressure of a tunnel.

    Browse all Neometrix product lines.

    Get a quotation

    Tell us the duty,
    and the step it must make.

    The projects desk replies within two working days with a facility concept, a proving plan you can check, and a budgetary quotation. Write to [email protected] or use the form.

    Enquire — shock tube facility Capability sheet (PDF) +91 7777 876 876
    ISO 9001 / 14001 ENGINEERED-TO-ORDER CLASS — SHOCK TUBE TEST FACILITY DUTY · TUBE AND DIAPHRAGM · GAS AND VACUUM · RELEASE · SENSORS AND TIMING · BUILD · PROVE — A SHOCK TUBE MAKES A PRESSURE STEP YOU CAN CALCULATE. ENGINEERED IN NOIDA · INDIA

    Trending Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat
    move to top arrow