200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Neometrix / EV Battery Test & Validation Systems / Supercapacitor Module Test System / NMX-SCM-117
    NMX-SCM-117 · ENGINEERED-TO-ORDER CLASS — DUTY · POWER STAGE · SENSING · CELL TAPS · HEAT · PROTECTION · PROVE

    Supercapacitor Test System. Read the step, then the slope.

    A supercapacitor module is a stack of cells with very little resistance and a great deal of charge, and it is judged by two readings that are easy to get wrong. Neometrix engineers the system that takes them: the power stage, the sensing, the cell taps and the heat.

    So the system has to know that the step is the resistance, the slope is the capacitance, and one weak cell sets the limit of the module.

    A supercapacitor module test system on a plain white studio background: a tall pale grey tester cabinet with a smooth plain front, two thick bright copper busbars leaving its right-hand side on small grey insulator blocks and curving down to a low pale grey open frame that holds a row of plain pale grey cylindrical cells joined at the top by a copper strip, a loose bundle of thin black leads with four small black clips on the strip, and no people
    Fig · 01 — A supercapacitor module test system: a tester cabinet, busbars to the module under test, and thin leads to its cells — illustrative render.
    The step
    is the resistancethe drop at the instant the current starts
    The slope
    is the capacitancethe straight fall that follows, at a constant current
    The cells
    are watched one by oneone weak cell sets the limit of the module
    The wires
    are four per terminalthe cable must stay out of the reading
    Status
    engineered to orderno delivery is claimed
    ISO 9001ISO 14001Test method and window from IEC 62576 or the maker's datasheet
    01
    Overview

    What a supercapacitor module test has to get right, and what goes wrong when it does not.

    Almost any DC source can charge and discharge a module and log the result, and still measure it wrongly, because the answer lives in a few millivolts and a few milliseconds.

    A supercapacitor module with its cell taps on a plain white studio background: four plain pale grey cylindrical cells standing side by side in a low pale grey frame, joined at the top by flat bright copper links, a thick copper terminal stud with a nut on each end cell, a thin black lead clipped to each of three links and running off to the right, and no people
    Fig · 02 — A module with a tap on every cell: cells in series, copper links between them and a thin lead on each link — illustrative render.

    Read the step, then the slope.

    What the system is for

    It charges and discharges a supercapacitor module under control, and measures what the module can do: its capacitance, its resistance, how well it keeps its charge, how much energy it returns and how hot it gets.

    Why a constant current

    A resistor's current falls as the voltage falls, so the curve bends. A constant current makes the voltage fall in a straight line, and a straight line can be read.

    The step and the slope

    The moment the current starts, the voltage drops by the current times the resistance. After that it falls at the current divided by the capacitance. One discharge gives both, so the idea is to read the step, then the slope.

    Why a capacitor is not a battery

    A battery's voltage stays nearly flat while its charge drains. A capacitor's voltage is its charge, so it falls all the way to nothing, and the system has to hold a constant current down to a very low voltage.

    Why four wires

    A module's resistance is small, and the cable from the tester can be as large. With one pair of wires the step would include the cable. So force and sense are separate, and the sense wires touch the module terminals.

    Why every cell is watched

    A module is cells in series. Each cell has its own leakage and its own capacitance, so the voltage is not shared equally, and the weakest cell reaches its limit first. A tap on every cell shows which one.

    Why leakage is a slow test

    A charged capacitor loses charge through leakage, slowly. To see it, the module is charged and left open, and its voltage is watched for hours at a steady temperature with a meter that does not load it.

    Why heat matters

    The current heats the module by the current squared times the resistance. A long cycling test can warm it enough to change the result, so the temperature is measured and limited, and the module can sit in a chamber.

    Why the energy matters

    A charged module stays charged for a long time. The system brings it back to zero at the end of every test, and a bidirectional source returns the energy to the supply instead of burning it.

    02
    The method

    Duty, power stage, sensing, cell taps and heat, protection, proof.

    Six steps in a fixed order. The four-wire sensing and the cell taps are the two that a quick job skips.

    1 · Duty

    The modules, their voltage window and current, the tests wanted, the temperatures, and the standard or datasheet that sets the method, are noted.

    2 · Power stage

    A bidirectional DC source and sink holds a constant current down to a very low voltage and returns the energy, so that the discharge is a straight line to the end.

    3 · Sensing

    Four-wire sensing at the module terminals and fast sampling catch the first instants, so that the step is the module's and not the cable's.

    4 · Cell taps and heat

    A tap on every cell and sensors on the module watch the voltage sharing and the temperature, so that the weakest cell is known and the heat is limited.

    5 · Protection

    Limits on every cell, interlocks, a discharge to zero and a shorting lead keep the module and the people safe, so that no charge is ever left behind.

    6 · Proof

    The system is checked on a reference resistor and a reference capacitor, every limit and interlock is tried, and the record goes with the system.

    Which fault, which safeguard

    What can go wrongWhy it happensWhat the system does about it
    The resistance reads too highthe cable and the contacts add their own resistance to the module'sfour-wire sensing at the module terminals, and a check on a reference resistor before every campaign
    The capacitance changes from test to testthe current or the voltage window was not the same each timea recipe that sets the window and the current, and stores them with every result
    The step is missedthe current was switched slowly, or the sampling was too slow to catch the first instantsa fast current edge, sampling that starts before the edge, and a record of the first moments
    One cell goes over its limitthe cells in a string do not share the voltage equallya tap on every cell, a limit on every tap, and a stop as soon as one cell reaches it
    The module warms while it cyclesthe current times the resistance is heat, and it grows with the square of the currenttemperature sensors, a limit, a rest between cycles, and a chamber when the temperature must be held
    The leakage reads wrongthe meter loaded the module, or the temperature drifted while it was watcheda high-impedance measurement, a steady temperature, and a wait that is long enough
    The module is left chargeda charged module does not drain by itself in any useful timea discharge to zero at the end of every test, a shorting lead for storage, and an interlock on the door
    A long test is losta power cut or a fault interrupted thousands of cyclesevery cycle logged as it happens with its recipe, and a restart that resumes where it stopped

    The step people underrate is the four-wire sensing. A system that never separated force from sense can charge and discharge a module and still report a resistance that belongs partly to the cable.

    03
    Work content

    What the system contains, element by element.

    Read it as a checklist: a system missing a row will still cycle a module, but it will not measure it truthfully.

    A supercapacitor module in a test chamber on a plain white studio background: a plain pale grey chamber box with its solid door standing open to the left, a low pale grey module case on a shelf inside it with two bright copper cables leaving its top and curving away to the right, a thin black lead running to a small pale grey sensor box on the shelf, a round port in the right-hand side wall, and no people
    Fig · 03 — A module in a chamber: copper cables through a port, and a thin lead to a sensor, so that the module is cycled while its temperature is held — illustrative render.
    ElementWhat it doesWhat matters
    Power stagecharges and discharges the modulea bidirectional DC source and sink with a low-noise output, so that the current is steady and the energy goes back to the supply
    Current controlholds a constant currenta fast edge when the current starts and stops, and a current that stays constant as the voltage falls
    Low-voltage endcarries the test down to nothinga stage that keeps its current down to a very low voltage, because a capacitor's voltage is its charge
    Terminal sensingmeasures the module, not the cableseparate force and sense wires, with the sense wires on the module terminals
    Cell tapsshow how the voltage is shareda thin lead on every link between cells, measured at the same instant, with a limit on each
    Temperatureshows how hot the module getssensors on the module and on the cells that run hottest, and a limit that stops the test
    Chamber pairingholds the temperaturea chamber from the Neometrix chamber line, with a cable port that keeps the sensing wires short
    Leakage meterwatches the voltage of a module left opena measurement that does not load the module, at a steady temperature, for long enough
    Protective limitsstop a test that has gone wronglimits on every cell, on the module and on the current, that stop the stage before the module is harmed
    Safety and dischargeleave nothing chargedinterlocks on the doors, a discharge to zero at the end, and a shorting lead for storage
    Recipes and datamake every result repeatablea recipe that stores the window, the current and the limits with every result, and a log of every cycle
    Testing & documentationprove the system firsta reference resistor and a reference capacitor checked, every limit and interlock tried, and a record the customer can inspect

    The elements that decide the result are the four-wire sensing and the cell taps. The first keeps the cable out of the reading, and the second shows which cell is holding the module back.

    Full specification — expand
    SystemA bidirectional DC source and sink that holds a constant current down to a very low voltage and returns the energy; four-wire sensing at the module terminals with fast sampling; a tap on every cell; temperature sensors on the module; limits on every cell, interlocks and a discharge to zero at the end of every test; recipes that store the window and the current with every result; and a check on a reference resistor and a reference capacitor, a limit and interlock test and documentation before handover
    The One IdeaRead the step, then the slope.
    Why Four WiresA module's resistance is small and the cable can be as large, so force and sense are separate and the sense wires touch the module terminals. Otherwise the step would include the cable
    Why Every CellA module is cells in series, and each has its own leakage and capacitance, so the voltage is not shared equally and the weakest cell reaches its limit first. A tap on every cell shows which one
    StandardsIEC 62576 sets test methods for the electrical characteristics of electric double-layer capacitors, covering capacitance, internal resistance, voltage maintenance and energy efficiency, and the system can be set to its method where the customer asks. The voltage window, the current and the limits come from that standard or the maker's datasheet. No certification or accreditation is claimed here
    ConfigurationsA bench module tester, a multi-module cycler rack, and a module station with a chamber
    Scope BoundaryThis page is the supercapacitor module test system, which measures the step, the slope, the cells, the leakage and the heat of a supercapacitor module. It is not a battery cycler, which cycles battery cells, modules and packs (see EV battery test system), not a load bank, which turns power into heat in steps (see load bank) and not an environmental chamber, which holds a test at temperature (see environmental test chambers). It does not make or certify a module, and it does not replace the maker's datasheet
    StatusNeometrix engineers supercapacitor module test systems to order, and no delivered supercapacitor module test system is claimed.
    04
    Configurations

    One method, three ways to build the system.

    The method, the sensing and the protection are shared. What changes is how many modules are tested at once, and at what temperature.

    Bench module tester

    One module, one answer

    For a laboratory or a module maker: one or two channels with four-wire sensing, cell taps and a recipe, to characterise a module and to check a batch against its datasheet.

    Multi-module cycler rack

    Many modules, one schedule

    For endurance work: several channels in a rack cycle modules side by side, each with its own limits and taps, and every cycle is logged as it happens.

    Module station with a chamber

    The same test, at temperature

    For modules whose behaviour depends on temperature: the module sits in a chamber from the Neometrix chamber line and is cycled and logged while the temperature is held.

    And the part that is not equipment at all, yet decides all three: the method. The voltage window, the current and the limits come from the standard or the maker's datasheet, not from the tester.

    05
    The drawings

    A reference set, drawn as real CAD sheets.

    Two sheets of one reference configuration: the arrangement of a bench supercapacitor module test system with three details, and the sequence of a test with the curves that show why a module is read by its step and then its slope. They show the plan, the module with its taps, the four-wire connection, the power loop and the protection. They carry tags and letters only. Every voltage, current and limit is fixed by design for the customer's modules.

    Reference drawing sheet one, the arrangement and details of a bench supercapacitor module test system. A plan shows a tester cabinet holding a power stage and a measuring unit, a chamber with a cable port, a module on a frame with four cells and three links, two force busbars from the power stage to the module terminals, two sense wires from the measuring unit to the same terminals, a cell-tap harness to the three links, a temperature sensor, a door interlock and a stored shorting lead. A front elevation shows the module: four cells in series, three links, two terminal studs, the voltage across each cell and across the whole module, a tap on every link and a temperature sensor. Detail A shows the four-wire connection: a power stage feeding the module through two cable resistances, the module as a resistance in series with a capacitance, and a sense pair from its terminals to a high-impedance measuring unit. Detail B shows the power loop: a supply, a bidirectional power stage and the module, with charge flowing one way, the energy returning the other way, and a recipe setting the stage. Detail C shows the protection: limits on every cell, a temperature limit and a door interlock stop the stage, then the module is discharged to zero and a shorting lead is used for storage. An item list numbers nine parts. A title block stamped reference configuration, not for construction
    Fig · 04 — Sheet 01, the arrangement: a plan, the module with its taps, the four-wire connection, the power loop and the protection. Reference configuration, letters only.
    Reference drawing sheet two, the sequence and the curves of a bench supercapacitor module test system. A sequence of boxes shows the steps of a test: charge to the window with every cell watched, hold, discharge at a constant current, open circuit to watch the leakage, then cycle with the recipe stored, discharge to zero, and a shorting lead for storage, with an interlock that lets no test start with the door open. Detail A is a computed plot of module voltage against time for a constant-current discharge at a current and at twice the current: a step down at the instant the current starts and then a straight fall, with twice the step and twice the slope at twice the current, and two dashed window lines. Detail B is a computed plot of the same discharge seen at the module terminals and at the tester terminals: the cable makes the step bigger and leaves the slope unchanged. Detail C is a computed plot of four cell voltages in series under one constant charging current: the cell with the smallest capacitance reaches the limit first and the charge stops there. A title block stamped reference configuration, not for construction
    Fig · 05 — Sheet 02, the sequence and the curves: the steps of a test with its interlock, the step and the slope, the cable in the reading and the weakest cell. Reference configuration, tags only.

    Every real system is drawn for its own modules, its own voltage window and its own method. These sheets are the arrangement and the order of working that a project set starts from. Approval of any drawing rests with the customer and the authority they name; none is claimed here.

    06
    Where it is used

    Wherever a supercapacitor module has to be measured, and nobody wants the cable in the answer.

    The common thread is a module with very little resistance, a result that has to be repeatable, and a weak cell that must not hide.

    Module makers

    Where modules are built from cells and every batch has to be characterised and shown to match its datasheet.

    Research laboratories

    Where new cells and new modules are cycled for months and the result has to be the same on the last day as on the first.

    Developers of energy-recovery systems

    Where a module takes and gives back energy in short bursts, and the designer must know its resistance and how hot it will get.

    Incoming inspection

    Where modules are checked before they are fitted, and a batch has to be proved the same before it goes into a system.

    07
    Watch

    See it in motion.

    A short walkthrough video of the supercapacitor test system.

    08
    FAQ

    Common questions.

    Longer answers, for readers who want the reasoning.

    Q · 01 What does a supercapacitor module test system actually do?
    It charges a supercapacitor module to a stated voltage, discharges it at a constant current, and measures what happens. From the discharge it reads the capacitance and the resistance. It leaves the module open and watches the voltage fall, which shows how well the module keeps its charge. It cycles the module many times and tracks how the capacitance and the resistance change. All the while it watches the voltage of every cell, the temperature and the current, and it stops the test if a limit is reached. At the end it brings the module back to zero, so that nothing is left charged. The system does not decide what a good module is. The standard or the maker's datasheet does, and the system measures against it and records the result.
    Q · 02 Why does the voltage fall in a straight line, and what do the step and the slope tell you?
    Because a capacitor's voltage is its stored charge divided by its capacitance. If the current is held constant, charge leaves at a steady rate, so the voltage falls at a steady rate, and the steepness of that line is the current divided by the capacitance. The resistance adds a second effect. At the instant the current starts, the voltage across the module drops at once by the current times the resistance, before the slow fall begins. So one discharge gives two readings on one curve, the step and then the slope, and neither needs the other to be known first. That is why the system holds the current constant, samples fast enough to catch the step, and keeps the cable out of the measurement.
    Q · 03 Why four wires, and why a tap on every cell?
    Because the two things a module test is trying to find are small and easily hidden. A module's resistance is small, and the cable between the tester and the module can have a resistance of the same order, so a single pair of wires would report the cable and the module together. Separate force and sense wires, with the sense wires on the module terminals, leave the cable out. The cells need a tap for a different reason. A module is cells in series, each with its own leakage and capacitance, so the voltage divides unevenly and the weakest cell reaches its voltage limit first. A reading across the whole module cannot show that. A tap on every link shows which cell is limiting the module, and the limit on each tap stops the test before that cell is harmed.
    Q · 04 How is leakage, or self-discharge, tested?
    By charging the module, holding it at its voltage for a stated time so that it settles, and then leaving it open and watching how far the voltage falls over a long wait. It is a slow test, and two things spoil it. The first is the meter: if it draws current, it becomes the leak, so the measurement has to be of very high impedance. The second is temperature, because leakage grows with it, so the module is held at a steady temperature, in a chamber if need be. The system records the voltage of the whole module and of every cell through the wait, so that a cell that leaks more than its neighbours shows up. The wait, the voltage and the temperature are set by the standard or the datasheet.
    Q · 05 Is this the same as a battery cycler or a load bank?
    No, and the differences are worth stating precisely. The EV battery test system page covers cyclers for battery cells, modules and packs, whose voltage barely moves while they run. The load bank page covers a bank that turns power into heat in steps. The environmental test chambers page covers chambers that hold a test at temperature. This page is the system that measures a supercapacitor module, whose voltage is its charge and falls all the way to nothing. It does not replace any of them, and it does not claim what they claim a second time.
    Q · 06 Has Neometrix built one of these?
    We would rather answer this plainly than let a page imply otherwise. Neometrix engineers supercapacitor module test systems to order, and no delivered supercapacitor module test system is claimed. What stands behind the offer is adjacent: the pages for the EV battery test system, the load bank and the environmental test chambers each describe a piece of the same kind of work, regenerative cycling, controlled electrical loading and held temperature, and each states its own status. The bidirectional power modules, the measuring instruments and the chamber are catalogue items, bought in, not invented. What Neometrix engineers is the system around them: the rack and the busbars, the four-wire and cell-tap wiring, the limits and interlocks, the recipes and the proof. So the honest position is that the system is engineered to order, the neighbouring disciplines are in the building, and the first system of this exact kind will be built around the customer's own modules rather than taken off a shelf.
    Q · 07 Which standard applies, and what can the system not do?
    IEC 62576 sets test methods for the electrical characteristics of electric double-layer capacitors, covering capacitance, internal resistance, voltage maintenance and energy efficiency, and the system can be set to its method where the customer asks. The voltage window, the current and the limits come from that standard or the maker's datasheet, and the customer states which one governs. The system measures a module and records the result. It does not make or certify a module, it is not a safety device for the people around it, and it does not replace the maker's datasheet. This page claims no certification or accreditation. No voltage, current, capacitance, resistance, temperature or time figure is printed here, and approval of a module rests with the customer and the authority they name; none is claimed here.
    Q · 08 What do you need from us to quote?
    Six things, and most of them describe your modules rather than the system. First, the modules: how many cells in series, their rated voltage and the current they must carry. Second, the tests: capacitance, resistance, leakage, efficiency, endurance, or all of them. Third, the method: the standard or datasheet that sets the window and the limits. Fourth, the temperature: whether the tests must run at a held temperature. Fifth, the scale: one module on a bench or many in a rack. Sixth, the record: what must be logged, and for how long. From that we come back with a system concept, a proving plan you can check, and a budgetary price.
    09
    Related

    The neighbouring pages, and how they differ from this one.

    Three neighbours: one cycles batteries, one turns power into heat, one holds the temperature.

    Browse all Neometrix product lines.

    Get a quotation

    Tell us the module,
    and the answer you need from it.

    The projects desk replies within two working days with a system concept, a proving plan you can check, and a budgetary quotation. Write to [email protected] or use the form.

    Enquire — supercapacitor module test system Capability sheet (PDF) +91 7777 876 876
    ISO 9001 / 14001 ENGINEERED-TO-ORDER CLASS — SUPERCAPACITOR MODULE TEST SYSTEM DUTY · POWER STAGE · SENSING · CELL TAPS · HEAT · PROTECTION · PROVE — READ THE STEP, THEN THE SLOPE. ENGINEERED IN NOIDA · INDIA

    Trending Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat
    move to top arrow