200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Environmental Test Chambers · Hub / Climatic · Corrosion · EMC · Fire · Impact / MIL-STD-461 · CISPR · IS 17051 / Noida · India
    CLIMATIC · CORROSION · EMI/EMC · FIRE · IMPACT

    Environmental Test Chambers & Simulators

    Neometrix engineers environmental test chambers and simulators for qualifying equipment against heat, cold, humidity, dust, salt, vacuum, electromagnetic interference, fire, impact and abuse. Pick the environment you need to simulate below, or start with the climatic and environmental test chambers, which cover −70 to +150 °C and 10 to 98 %RH.

    Neometrix walk-in climatic and environmental test chamber
    Fig · 01 Walk-in climatic and environmental test chamber — −70 to +150 °C, 10 to 98 %RH
    Standards referenced:
    MIL-STD-461 CISPR IS 17051:2018 ISO 12619
    Products
    16models
    Climatic Range
    -70/150°C
    Thermal Vacuum
    10⁻⁶mbar
    EMC Shielding
    ≥100dB
    Hangar Fire Chamber
    40×15×10m
    01
    The range

    Environmental test equipment by condition.

    Every item below has its own page with full specifications and photographs. Choose by the environment you need to simulate.

    Climatic & Environmental Test Chambers — Neometrix
    Climatic & corrosion

    Climatic & Environmental Test Chambers

    Reach-in to walk-in and drive-in chambers with uniformity of ±2 °C at nine points.

    −70 to +150 °C · 10–98 %RH
    Dust & Sand Test Chamber — Neometrix
    Climatic & corrosion

    Dust & Sand Test Chamber

    Steady dust cloud with partial vacuum on the casing, and blown dust and sand tests. Engineered to order.

    Enclosure dust · blown sand
    Salt Spray & Corrosion Test Chamber — Neometrix
    Climatic & corrosion

    Salt Spray & Corrosion Test Chamber

    For defence, automotive and marine parts. Engineered to order.

    Salt fog · cyclic · walk-in
    Thermal Shock Test Chamber — Neometrix
    Climatic & corrosion

    Thermal Shock Test Chamber

    Carries a basket of parts between a hot zone and a cold zone. Engineered to order.

    Two-zone · three-zone
    Thermal Vacuum Chamber (TVAC) — Neometrix
    Climatic & corrosion

    Thermal Vacuum Chamber (TVAC)

    LN2 / GN2 radiative shrouds for satellite and payload testing.

    ~10⁻⁶ mbar · −180 to +150 °C
    EMI / EMC Test Laboratory — Neometrix
    Electromagnetic & fire

    EMI / EMC Test Laboratory

    Semi-anechoic chambers with NSA ±4 dB and automotive and EV EMC test suites.

    ≥100 dB · MIL-STD-461 · CISPR
    Fire Resistance Test Rig — Neometrix
    Electromagnetic & fire

    Fire Resistance Test Rig

    Rates building and industrial elements for fire resistance.

    Furnace · restraint · loading
    Hangar Fire Test Facility — Neometrix
    Electromagnetic & fire

    Hangar Fire Test Facility

    Fire simulation chamber for validating hangar fire-fighting systems, with metered LDO / LPG ignition.

    40 × 15 × 10 m chamber
    Bird-Strike Test Facility — Neometrix
    Impact, pressure & abuse

    Bird-Strike Test Facility

    Proves windshields, canopies, intake structures and wings against bird impact. Engineered to order.

    Pneumatic launcher
    Head Impact Test Rig — Neometrix
    Impact, pressure & abuse

    Head Impact Test Rig

    Electro-hydraulic seat-headrest impact test system measuring force, deflection and energy.

    Up to 250 km/h
    Ballistic Evaluation Testing Laboratory — Neometrix
    Impact, pressure & abuse

    Ballistic Evaluation Testing Laboratory

    Velocity measurement from 50 to 1,800 m/s with V50 and drop tests.

    IS 17051:2018 · NIJ 0106.06
    Deep Ocean Pressure Simulator — Neometrix
    Impact, pressure & abuse

    Deep Ocean Pressure Simulator

    Brings the deep sea into the lab, then brings it back out slowly.

    Engineered to order
    Battery Abuse Test Chamber — Neometrix
    Impact, pressure & abuse

    Battery Abuse Test Chamber

    Built for the failure it provokes, containing cell and pack abuse tests safely.

    With gas scrubber
    Aerospace & Industrial Autoclave — Neometrix
    Process & life testing

    Aerospace & Industrial Autoclave

    Heated pressure vessels that cure composites under controlled conditions. Engineered to order.

    Heat · pressure · vacuum
    Accelerated Life Test Bench (PRV) — Neometrix
    Process & life testing

    Accelerated Life Test Bench (PRV)

    Automated accelerated life and endurance bench for hydrogen pressure relief valves.

    ISO 12619 Part 10 · UN ECE R134
    Hydrogen Pressure-Cycling Test Facility — Neometrix
    Process & life testing

    Hydrogen Pressure-Cycling Test Facility

    Runs a tank through its full fill-and-vent service life before its first real fill.

    GTR-13 / ISO 19881 pattern
    02
    What is simulated

    What each chamber simulates.

    A product meets many environments in service, and each needs its own chamber.

    Heat, cold and humidityEquipment is cycled through temperature and humidity extremes. See the climatic chambers and the thermal shock chamber.
    Dust, sand and saltEnclosures are tested against blown dust, sand and salt fog. See the dust and sand chamber and the salt spray chamber.
    Space vacuumPayloads are tested in high vacuum with a cold shroud. See the thermal vacuum chamber.
    Electromagnetic interferenceEmissions and immunity are measured in a shielded semi-anechoic room. See the EMI / EMC test laboratory.
    FireBuilding elements and hangar fire-fighting systems are tested against real fire. See the fire resistance rig and the hangar fire facility.
    Impact, pressure and abuseParts are hit, squeezed or pushed to failure under control. See the bird-strike facility, the deep ocean pressure simulator and the battery abuse chamber.
    03
    Choosing

    Choosing an environmental test chamber.

    Five questions settle most selections.

    Start with the environment and the standard — the chamber follows.
    • Which environment? Heat, humidity, dust, salt, vacuum, EMI, fire or impact decides the chamber.
    • What size? Chambers range from reach-in to walk-in and drive-in.
    • What range? Give the temperature, humidity, pressure or field-strength range you need.
    • Which standard? Tell us whether you work to MIL-STD-461, CISPR, IS 17051 or another specification.
    • What is tested? Part weight, power dissipation and fixtures set the chamber design.

    For related reading, see our pressure testing machines and EV and battery test equipment.

    04
    FAQ

    Frequently asked questions.

    Plain-language answers, drawn from the individual product pages.

    Q · 01 What is an environmental test chamber?
    It is an enclosure that reproduces conditions such as temperature, humidity, dust, salt fog, vacuum or fire so a product can be qualified before it enters service. Neometrix engineers chambers for each of these conditions.
    Q · 02 What range do your climatic chambers cover?
    The climatic and environmental chambers cover −70 to +150 °C and 10 to 98 %RH, with uniformity of ±2 °C at nine points, from reach-in to walk-in and drive-in sizes.
    Q · 03 Do you make thermal vacuum chambers?
    Yes. The thermal vacuum chambers reach about 10⁻⁶ mbar with LN2 / GN2 radiative shrouds from −180 to +150 °C, for satellite and payload testing.
    Q · 04 Can you build an EMI / EMC laboratory?
    Yes. The EMI / EMC laboratories use semi-anechoic chambers with shielding of at least 100 dB and NSA ±4 dB, with MIL-STD-461 and CISPR test suites and automotive and EV EMC capability.
    Q · 05 What fire and impact test equipment do you make?
    Neometrix builds a fire resistance test rig, a 40 × 15 × 10 m hangar fire test facility, a bird-strike test facility with a pneumatic launcher and a head impact test rig with impact velocity up to 250 km/h.
    Q · 06 Can the equipment be built to order?
    Yes. Most of this equipment is engineered to order. Send the environment, range, size and the standard you work to, and we will propose a configuration.
    Get a quote

    Tell us which environment
    you need to simulate.

    Send the environment, range, size and standard. We will recommend a chamber and walk through the configuration before you commit.

    Request a quote +91 7777 876 876

    Trending Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat
    move to top arrow