Distributor Valve Test Rig

About

The system is designed to test the performance of the Distributor valve. Distributor Valve works on Pressure difference in the Brake Pipe. The system is consisting Brake Pipe, Auxiliary Reservoir, Brake Cylinder and Control Reservoir.

The DV Test Rig Test the following Parameters one by one :

  • Charging Time of AR & CR
  • Brake Application Time
    1. In Full Service Application
    2. In Emergency Application
  • Brake Releasing Time
    1. In Full Service Application
    2. In Emergency Application
  • Max. Brake Cylinder Pressure
    1. In Full Service Application
    2. In Emergency Application
  • Leakage Test
  • Sensitivity
  • Graduated Application
  • Graduated Release
  • Graduated Release
  • Re-feeding Test
  • Availability of BP pressure
  • Overcharge Protection Test
  • Quick Release Valve Test

Image Gallery

Technical Details

  • Medium: Air
  • Pressure Rating: 10 Kg/cm2
  • Air supply Pressure Range: 8-10 Kg/cm2
  • Flow Rate: 2400 LPM
  • Temperature Range: Ambient

1. The System can be used to test the Distributor Valve for Coach and Wagon (Loaded or Empty)
2. The stroke Length of the Brake Cylinder can be adjustable manually from machine according to the diameter of Brake Cylinder.
3. The system works on a predefined Test Sequence with an option to test the particular test.

Key Features

  • The System works both in Automatic and Manual mode.
  • Stroke Length of the Brake Cylinder can be adjustable.
  • Power back up to 1 hour.
  • Works on predefined Test Sequence with Option to test the particular test.
  • Acceptance criteria of the unit can be programmed.

Download Gallery

Datasheet Product Catalog

Engineering Design Documents

PPT Gallery

Video Gallery

Social Media

Our Products

Chat With Us