200M 400M 200M
RNG: 2.4 KM
BRG: 047°
ALT: 3,200 FT
SPD: 480 KTS
HDG: 012° N
TGT: ALPHA-7
MODE: SEARCH
PWR: NOMINAL
FREQ: X-BAND
STATUS: LOCK
NAVTGTWPNDEFRDRCOM
MIL-STD-1553IFF: ACTIVELINK-16: SYNC
SECTOR: ALPHA
THREAT: CLEAR
RADAR: ACTIVE
TRACK: 6 TGT
LAT 28.6213°N LON 77.3873°E
NX
Neometrix Target Acquired
GB Flag English
English Flag English
Indian Flag हिन्दी
Francis Flag Français
Dutch Flag Deutsch
Spanish Flag Español
Arabic Flag العربية
Russian Flag Русский
Japanese Flag 日本語
Portuges Flag Português
Italian Flag Italiano
Israel Flag עברית
Chinese Flag 中文
Korean Flag 한국어
Thailand Flag ไทย
Vietnamese Flag Tiếng Việt
Indonesia Flag Bahasa Indonesia
Malasia Flag Bahasa Melayu
Kiswahili Flag Kiswahili
Ethiopia Flag አማርኛ
isizulu Flag isiZulu
Hausa Flag Hausa
    Gas Distribution System / <5 ppb Moisture · <1 ppb O2 / ATEX/CE Gas Detection / India
    GASDS · AUTO-CHANGEOVER GAS PANEL

    Gas Distribution System, purified to <5 ppb moisture.

    A fully engineered assembly that integrates automatic dual-cylinder changeover manifolds, multi-stage purification modules, and point-of-use SS 316L regulators to deliver Zero Air, N2, H2, He, and CH4 from high-pressure cylinders to laboratory panels — with an ATEX/CE-certified multi-channel gas detection system monitoring every line for leaks and unsafe conditions.

    Gas distribution system - industrial and defence multi-point gas supply manifold and pressure regulation distribution network by Neometrix
    Fig · 01 Auto-changeover manifold bank · purification modules · POU regulator panel
    Designed and manufactured to:
    ATEX CE IECEx
    Inlet Pressure
    230bar
    Moisture
    <5ppb
    Hydrocarbons
    <15ppb
    Residual O2
    <1ppb
    POU Regulators
    100psi
    01
    Overview

    Five gases, one distribution panel.

    The Neometrix Gas Distribution System is a fully engineered assembly — among the laboratory gas distribution system installations Neometrix builds for industrial gas distribution systems use — that integrates automatic dual-cylinder changeover manifolds, multi-stage purification modules, and point-of-use SS 316L regulators to deliver ultra-pure gases to laboratory instruments without interruption.

    Gas distribution system product view - centralised gas supply header and point-of-use pressure regulation panel for industrial and defence facilities by Neometrix
    Fig · 02 Multi-outlet gas manifold, valves and pressure gauges on the distribution header

    The system integrates automatic dual-cylinder changeover manifolds, multi-stage purification modules (moisture <5 ppb, hydrocarbons <15 ppb, oxygen <1 ppb), and point-of-use SS 316L regulators (0–100 psi) to deliver Zero Air, N2, H2, He, and CH4 from high-pressure cylinders to laboratory panels. Electropolished SS 316/316L tubing and compression fittings form the distribution network, while an ATEX/CE-certified multi-channel gas detection panel with SS 316 transmitter heads provides 4–20 mA outputs, relay contacts, and Modbus communication.

    All components are mounted in powder-coated MS enclosures configured per the full-layout drawings, with flexible hoses, fittings, and enclosures installed and commissioned to work-order specification.

    One manifold bank. Five gas lines. Continuous, contamination-free supply.

    Designed for analytical instrumentation, catalyst R&D, process simulation, and safety-critical inerting environments, this gas delivery system among Neometrix's broader gas supply systems is modular and scalable, fitting neatly into standard laboratory panel layouts with straightforward expansion.

    02
    Architecture

    Six subsystems, one gas panel.

    Every subsystem of the Gas Distribution System works together to deliver uninterrupted, ultra-pure gas supply with integrated safety monitoring throughout.

    Sub · 01

    Auto Changeover Manifold

    A pilot-operated valve senses when the primary cylinder bank pressure falls to a preset point, triggering an uninterrupted switch to the reserve bank without manual intervention.

    Sub · 02

    Purification Modules

    Cartridge-type traps in SS 304 panels lower moisture to <5 ppb, remove hydrocarbons to <15 ppb, and scavenge residual O2 to <1 ppb; cartridges snap in/out via quick-release clamps.

    Sub · 03

    Point-of-Use Regulation

    Compact SS 316L regulators at instrument inlets maintain stable 0–100 psi pressures via diaphragm-sensed design, integrated filters, and isolation valves for maintenance.

    Sub · 04

    Distribution Network

    Electropolished SS tubing ensures smooth, inert flow with minimal dead volume; compression fittings and flexible braided hoses accommodate routing and vibration isolation.

    Sub · 05

    Detection & Control

    A 16-channel ATEX/CE panel aggregates analog (4–20 mA) and digital (Modbus RTU) signals from SS 316 sensor heads, with programmable alarms and relay outputs for automated shutdown.

    Sub · 06

    Panel Assembly

    Powder-coated MS enclosures built to the full-layout drawing, with standardized frame sizes, knock-outs, and mounting rails for ergonomic visibility and access.

    03
    Key Features

    Built for uninterrupted supply.

    The features that make this gas distribution system suitable for analytical, R&D and safety-critical laboratory environments.

    F · 01

    Auto-Changeover Manifold

    Switches to the standby cylinder bank on pressure drop, ensuring uninterrupted lab gas supply without manual intervention.

    Zero Downtime
    F · 02

    Multi-Stage Purification

    Sequential purification trains remove moisture (<5 ppb), hydrocarbons (<15 ppb), and residual O2 (<1 ppb) per line.

    Sub-ppb Purity
    F · 03

    Point-of-Use Regulation

    SS 316L point-of-use regulators deliver 0–100 psi directly at instrument inlets with integrated shut-off valves.

    SS 316L
    F · 04

    Electropolished Distribution

    SS 316/316L tubing (¼″ and ⅝″) with compression fittings; all connections are helium leak-tested.

    Helium Leak Tested
    F · 05

    ATEX/CE Gas Detection

    Multi-channel detector with SS 316 heads provides 4–20 mA, Modbus RS-485, and visual/audible safety alarms.

    ATEX · CE · IECEx
    F · 06

    Modular Panel Assembly

    Powder-coated MS enclosures with dual-scale gauges, relief valves, and isolation valves install in standard lab panels.

    Scalable Assembly
    05
    Downloads

    General, layout & design drawings.

    General catalog, panel layout, and GA design drawings for the Gas Distribution System, available as PDF for procurement and technical review.

    06
    Specifications

    Full technical parameters.

    Key system parameters for the standard Neometrix Gas Distribution System configuration.

    Inlet PressureUp to 230 bar (3,335 psi)
    Outlet Pressure Ranges0–14 bar (primary panels); 0–100 psi (POU regulators)
    Purification PerformanceMoisture <5 ppb; Total Hydrocarbons <15 ppb; O2 <1 ppb
    Manifold MaterialSS 316L, electropolished; pilot-operated valves; residual pressure <1 bar
    Tubing & FittingsSS 316/316L electropolished tubing (¼″×0.035″, ⅝″×0.028″); compression fittings; helium-leak tested
    Regulator MaterialSS 316L body and poppet; Hastelloy diaphragm; PCTFE/EPDM seals; inlet filter 10 µm mesh
    Detection Panel16 channels; 4–20 mA inputs/outputs; RS-485 Modbus; ATEX/IECEx; relay contacts (NO/NC)
    Sensor HeadsSS 316 housing; cast aluminum LM-6 enclosure; IP66; Gas Groups IIA/IIB
    Flexible HosesSS core, braided SS sheath; 1 m length; 200 bar rating
    Panel EnclosuresPowder-coated MS; standard 600 × 400 mm frames; adjustable mounting rails
    07
    Applications

    Where it supplies gas.

    From analytical instrumentation to safety-critical environments, this gas distribution system serves research and industrial laboratories that demand sub-ppb purity.

    A · 01Analytical instrumentation: supplies carrier and calibration gases to GC, GC-MS, and FID detectors, where ultra-pure zero air (<0.1 ppm THC) prevents baseline drift and enhances sensitivity.
    A · 02Catalyst R&D: feeds ultra-clean reactant gases for kinetic studies in microreactors or fixed-bed setups, where trace impurities can poison catalysts and skew activity measurements.
    A · 03Process simulation: supports pilot-scale reactors requiring precise ratios of H2, N2, or CH4 under controlled pressures for scale-up validation in chemical or petrochemical research.
    A · 04Safety-critical environments: in inerting or blanketing applications (gloveboxes, Schlenk lines), integrated detection and automatic shutdown protect personnel and samples from asphyxiation or explosion risks.
    08
    In Depth

    The complete technical read.

    Engineering narrative for design engineers, procurement teams, and lab managers who want the full picture before committing.

    Introduction

    The Gas Distribution System is a turnkey solution designed to supply ultra-pure gases — Zero Air (ZA), Nitrogen (N2), Hydrogen (H2), Helium (He), and Methane (CH4) — from high-pressure cylinders to laboratory instruments with precision, safety, and uninterrupted operation. It integrates automatic cylinder changeover, multi-stage purification, point-of-use regulation, stainless-steel distribution, and real-time gas detection into a modular, scalable assembly that fits neatly into standard panel layouts.

    Auto changeover manifold

    • Automatic switching: a pilot-operated valve senses when the primary cylinder bank pressure falls below a preset threshold, triggering an uninterrupted switch to the standby bank.
    • Zero manual intervention: maximizes gas usage and eliminates the need for operators to monitor cylinder pressure continuously.
    • Bank configuration: five dual-cylinder changeover banks serve the ZA, N2, H2, He and CH4 lines with an additional spare purification module.

    Multi-stage purification trains

    Each gas stream flows through cartridge-type traps housed in SS 304 panels with quick-release clamps for rapid element changes:

    • Desiccant stage: lowers moisture to <5 ppb.
    • Carbon bed: removes hydrocarbons to <15 ppb.
    • Oxygen scavenger: ensures residual O2 <1 ppb.

    Point-of-use regulation

    Ultra-miniature, single-stage SS 316L regulators positioned at instrument inlets maintain stable 0–100 psi pressures. Their diaphragm-sensed design and integrated 10 µm mesh filters deliver contaminant-free gas with optimized flow characteristics, and integrated shut-off valves allow safe line isolation for maintenance.

    Distribution network

    • Electropolished tubing: leak-tight SS 316/316L tubing (¼″×0.035″, ⅝″×0.028″) ensures smooth, inert flow with minimal dead volume.
    • Compression fittings: tees, unions, and reducers provide versatile routing across the full-layout drawing.
    • Flexible braided hoses: custom-length pigtails and SS-braided hoses accommodate movement and vibration isolation.
    • Leak testing: all connections undergo helium leak testing to <1×10−9 mbar·L/s.

    Gas detection & safety

    An ATEX/CE-certified, 16-channel multi-channel detector panel monitors O2, combustibles, and toxic gases via SS 316 transmitter heads housed in cast-aluminum LM-6, IP66-rated enclosures rated for Gas Groups IIA/IIB. The panel provides 4–20 mA outputs, programmable relays, and RS-485 Modbus communications with visual/audible alarms, enabling automated shutdown upon hazardous conditions.

    Panel assembly

    Enclosures are powder-coated MS, built per the full-layout drawing with standardized 600 × 400 mm frame sizes, knock-outs, and adjustable mounting rails. Regulators, dual-scale gauges, relief valves, and isolation valves are ergonomically arranged for visibility and maintenance access.

    Bill of materials (excerpt)

    ItemQuantity
    Auto Changeover Dual-Cylinder Manifold5 banks
    Gas Purification Modules6 (ZA, N2, H2, He, CH4, spare)
    Point-of-Use RegulatorsZA: 17; N2: 18; H2: 11; He: 10; CH4: 4
    SS Tubing (¼″×0.035″)550 m
    SS Tubing (⅝″×0.028″)25 m
    Compression Fittings>300
    Gas Detection Panel & Transmitters1 panel; 5 head units
    Flexible Braided Hoses10 (1 m each)
    Control Panel Enclosures17 secondary + junction boxes

    Technical specifications

    ParameterSpecification
    Inlet PressureUp to 230 bar (3,335 psi)
    Outlet Pressure Ranges0–14 bar (primary panels); 0–100 psi (POU regulators)
    Purification PerformanceMoisture <5 ppb; Total Hydrocarbons <15 ppb; O2 <1 ppb
    Manifold MaterialSS 316L, electropolished; pilot-operated valves; residual pressure <1 bar
    Tubing & FittingsSS 316/316L electropolished tubing; compression fittings; helium-leak tested
    Regulator MaterialSS 316L body and poppet; Hastelloy diaphragm; PCTFE/EPDM seals
    Detection Panel16 channels; 4–20 mA; RS-485 Modbus; ATEX/IECEx
    Sensor HeadsSS 316 housing; IP66; Gas Groups IIA/IIB
    Flexible HosesSS core, braided SS sheath; 1 m length; 200 bar rating
    Panel EnclosuresPowder-coated MS; 600 × 400 mm frames; adjustable mounting rails

    Conclusion

    The system delivers a highly reliable, safe, and modular platform for distributing multiple ultra-pure gases in demanding R&D and analytical environments. Its automated changeover, advanced purification, localized regulation, and integrated safety controls ensure continuous, contamination-free supply tailored to evolving laboratory needs.

    09
    FAQ

    Common questions.

    Plain-language answers from the engineering team.

    Q · 01 What is the Gas Distribution System?
    The Gas Distribution System is a precision-engineered assembly designed and manufactured by Neometrix Engineering Pvt Ltd, India, that supplies ultra-pure Zero Air, N2, H2, He and CH4 from high-pressure cylinders to laboratory instruments with automatic cylinder changeover, multi-stage purification and integrated gas detection.
    Q · 02 Who manufactures the Gas Distribution System?
    The Gas Distribution System is designed and manufactured by Neometrix Engineering Pvt Ltd, a leading laboratory and industrial gas system manufacturer based in India.
    Q · 03 What level of gas purity does the system achieve?
    Sequential purification trains reduce moisture to below 5 ppb, total hydrocarbons to below 15 ppb, and residual oxygen to below 1 ppb, per gas line, meeting the demands of GC, GC-MS and FID analytical instrumentation.
    Q · 04 What industries use the Gas Distribution System?
    The Gas Distribution System is used across analytical instrumentation, catalyst R&D, process simulation, and safety-critical inerting/blanketing environments in research laboratories and industrial facilities.
    Q · 05 Is the Gas Distribution System customizable?
    Yes, Neometrix offers customized versions of the Gas Distribution System — cylinder-bank count, gas-line combinations, regulator ranges and panel-enclosure layouts — tailored to specific client requirements.
    Q · 06 Does the Gas Distribution System comply with relevant standards?
    Yes, the multi-channel gas detection panel is ATEX/CE and IECEx certified, and all tubing connections are helium leak-tested; the system is built to customer-specified IS and ISO requirements.
    Q · 07 What are the key features of the Gas Distribution System?
    Key features include auto-changeover dual-cylinder manifolds, multi-stage purification, SS 316L point-of-use regulators, electropolished SS tubing, an ATEX/CE gas detection panel with 4–20 mA and Modbus outputs, and powder-coated MS panel enclosures.
    Q · 08 Can the gas detection panel be integrated with plant monitoring systems?
    Yes, the 16-channel detection panel provides 4–20 mA analog outputs, programmable relay contacts and RS-485 Modbus communication for integration with SCADA and building/plant monitoring systems.
    Q · 09 What after-sales support does Neometrix provide?
    Neometrix provides comprehensive after-sales support including installation, commissioning, operator training, preventive maintenance, and on-site service for the Gas Distribution System.
    Q · 10 How can I get a quotation for the Gas Distribution System?
    You can request a quotation for the Gas Distribution System by contacting Neometrix Engineering Pvt Ltd through https://neometrixgroup.com/products/gas-distribution-system or by phone at +91-7777-876-876.
    Get a proposal

    Tell us your gas-line and
    purity requirements.

    We size the manifold banks, purification trains, regulators and detection panel, and walk through the customization options with your lab team before you commit.

    Request proposal +91 7777 876 876

    Similar Products

    Share This Page

    Engineered To Standards Used In UK, NATO & U.S. Defence Procurement
    DEF STAN (UK MoD)
    NATO STANAG
    RTCA/EUROCAE DO-160
    MIL-SPEC / MIL-STD
    Address
    E-148, Sector-63, Noida, Delhi-NCR, India
    Phone
    Email
    Working Hours
    8:30 AM – 5:30 PM  ·  Mon – Sat
    move to top arrow