Refrigeration System

About

The High Pressure Refrigerant Recovery & Recharging System is an advanced industrial solution designed for the efficient recovery, decanting, and recharging of refrigerants like R-32 and other HFCs. With a >99 percent recovery efficiency, it minimizes refrigerant wastage, ensuring cost savings for OEMs and industrial users. Featuring high-pressure performance (>12 bar recovery, >16 bar supply), automated controls, and optional remote monitoring, it streamlines refrigerant handling for HVAC, refrigeration, food processing, and industrial applications. It is ideal for optimizing refrigerant management while maintaining safety and operational efficiency.
No Image

Image Gallery

Technical Details

  • Air Drive Pressure: Operates efficiently at a pressure range of 5 to 6 bar.
  • Air Consumption: Requires an air supply of 40 to 50 SCFM for optimal performance.
  • Recovery Efficiency: Achieves a refrigerant recovery rate exceeding 99%, minimizing losses.
  • Maximum Recovery Pressure & Storage Capacity: Supports refrigerant recovery at pressures greater than 12 bar, with a working capacity of 300 liters.
  • Maximum Supply Pressure: Capable of delivering refrigerant at a pressure exceeding 16 bar.
  • Automation & Control: The system includes fully automated operations for ease of use, with an optional remote control and monitoring station.
  • Delivery Pump System: Can be integrated with an optional delivery pump for enhanced refrigerant transfer efficiency.
  • Monitoring & Safety Features: Equipped with real-time monitoring and safety mechanisms to prevent overpressure conditions and ensure secure operations.
  • HVAC & Refrigeration Industry
  • Food processing, preservation and distribution.
  • Chemical and process industries.
  • Special Applications such as cold treatment of metals, medical, construction, ice skating etc.

Key Features

  • High Recovery Efficiency (>99%)
  • Plug & Play Installation
  • Advanced Automation & Control
  • High-Pressure Performance
  • Optional Delivery Pump System
  • Complete Evacuation of Gas
  • Energy-Efficient Operation
  • Built for Durability & Reliability

Media Gallery

Video Gallery

PPT Gallery

Download Gallery

×

Enquire Now

and we will get back to you.

Details

The High Pressure Refrigerant Recovery & Recharging System is an advanced, industrial-grade solution designed for efficient refrigerant handling in a variety of
applications. This system is specifically engineered to recover, decant, and recharge refrigerants such as R-32 and other hydrofluorocarbons (HFCs) while minimizing wastage and optimizing efficiency.

Traditional refrigerant transfer methods often leave a significant portion of the gas in vapor form inside supply tanks, leading to financial losses for OEMs and industrial users. The High Pressure Refrigerant Recovery & Recharging System eliminates this issue by maximizing recovery efficiency (>99%) and ensuring complete gas evacuation.

This high-pressure system is widely used in sectors that require precise refrigerant
handling, including air conditioning manufacturing, refrigeration systems, and specialized
cooling applications.

Key Features & Benefits
1. High Recovery Efficiency (>99%)
 • The system ensures that almost all refrigerant from the supply tank is recovered and recharged, reducing wastage.
 • Helps OEMs and industrial users save costs by preventing unnecessary refrigerant losses.

2. Plug & Play Installation
 • Designed for easy setup and quick deployment.
 • Reduces installation time, requiring minimal technical expertise.

3. Advanced Automation & Control
 • Fully automated operations minimize manual intervention.
 • Smart monitoring capabilities ensure precise refrigerant handling.
 • Optional remote control & monitoring station allows operators to track system performance in real time.

4. High-Pressure Performance
 • Works at air drive pressure levels between 5 and 6 bar, ensuring efficient refrigerant flow.
 • Can safely recover and store refrigerants at pressures exceeding 12 bar, with a working capacity of 300 liters.
 • Provides a maximum supply pressure greater than 16 bar, making it ideal for high-performance applications.

5. Optional Delivery Pump System
 • Allows seamless refrigerant transfer for different operational needs.
 • Enhances flexibility by enabling integration with multiple storage and distribution systems.

6. Complete Evacuation of Gas
 • Unlike conventional systems, the High Pressure Refrigerant Recovery & Recharging System ensures complete evacuation of residual gas, maximizing efficiency.

7. Energy-Efficient Operation
 • The system is designed to optimize air consumption, requiring 40 to 50 SCFM, ensuring that operations are both power-efficient and cost-effective.

8. Built for Durability & Reliability
 • Engineered to withstand tough industrial environments.
 • Designed with high-quality materials to ensure longevity and minimal maintenance requirements.

Technical Specifications
 • Air Drive Pressure: Operates efficiently at a pressure range of 5 to 6 bar.
 • Air Consumption: Requires an air supply of 40 to 50 SCFM for optimal performance.
 • Recovery Efficiency: Achieves a refrigerant recovery rate exceeding 99%, minimizing losses.
 • Maximum Recovery Pressure & Storage Capacity: Supports refrigerant recovery at pressures greater than 12 bar, with a working capacity of 300 liters.
 • Maximum Supply Pressure: Capable of delivering refrigerant at a pressure exceeding 16 bar.
 • Automation & Control: The system includes fully automated operations for ease of use, with an optional remote control and monitoring station.
 • Delivery Pump System: Can be integrated with an optional delivery pump for enhanced refrigerant transfer efficiency.
 • Monitoring & Safety Features: Equipped with real-time monitoring and safety mechanisms to prevent overpressure conditions and ensure secure operations.

Applications
The High Pressure Refrigerant Recovery & Recharging System is widely used across multiple industries due to its ability to handle refrigerants efficiently and safely. Key
application areas include:

1. HVAC & Refrigeration Industry
 • Air Conditioner & Refrigerator Manufacturers: Used for precise refrigerant recovery and recharging in production and servicing.
 • Chillers & Deep Freezers: Essential for commercial and industrial cooling applications.

2. Food Processing & Preservation
 • Maintains optimal refrigerant levels for cold storage and food processing units.
 • Ensures efficiency in frozen food distribution and logistics.

3. Chemical & Process Industries
 • Used in industrial cooling for chemical plants, pharmaceutical industries, and specialized process industries.
 • Helps maintain precise temperatures in critical manufacturing processes.

4. Specialized Cooling Applications
 • Cold treatment of metals: Used in metal processing plants for cryogenic treatment.
 • Medical & healthcare applications: Supports refrigeration in hospitals, laboratories, and vaccine storage units.
 • Construction & Ice Skating Rinks: Helps maintain the required refrigeration levels in large-scale commercial projects.

Why Choose the High Pressure Refrigerant Recovery & Recharging System?
Unmatched Recovery Efficiency
 • Achieves >99% refrigerant recovery, minimizing losses and reducing operational costs.

Superior Build Quality & Durability
 • Designed for long-term industrial use, even in demanding conditions.

Flexible & Customizable
 • Can be tailored with optional delivery pumps and remote monitoring stations to suit specific industry needs.

Optimized for Cost-Efficiency
 • Reduces refrigerant waste, enhances efficiency, and improves overall profitability for OEMs and industrial users.

Trusted by Industry Leaders
 • Developed with technical collaboration with refrigeration experts, ensuring reliability and cutting-edge performance.

Trending Products

Share This Page

Chat With Us

Bomb Shell Hydraulic Pressure Testing Machine

×

Dynamic Snubber (Shock Arrestor) Test Facility

×